{"id":10840,"date":"2026-08-29T23:43:11","date_gmt":"2026-08-29T15:43:11","guid":{"rendered":"https:\/\/q8bbzjnpm5.wpdns.site\/?p=10840"},"modified":"2026-08-29T23:43:11","modified_gmt":"2026-08-29T15:43:11","slug":"quality-control-points-and-optimization-paths-of-power-transformer-manufacturing-process","status":"publish","type":"post","link":"https:\/\/subian-electric.com\/ar\/news\/quality-control-points-and-optimization-paths-of-power-transformer-manufacturing-process\/","title":{"rendered":"\u0646\u0642\u0627\u0637 \u0645\u0631\u0627\u0642\u0628\u0629 \u0627\u0644\u062c\u0648\u062f\u0629 \u0648\u0645\u0633\u0627\u0631\u0627\u062a \u062a\u062d\u0633\u064a\u0646 \u0639\u0645\u0644\u064a\u0629 \u062a\u0635\u0646\u064a\u0639 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629"},"content":{"rendered":"<p>\u0645\u062d\u0648\u0644 \u0628\u0645\u0642\u0627\u0648\u0645\u0629 \u0644\u0641 \u062f\u0627\u062e\u0644 0.5% \u0628\u064a\u0646 \u0627\u0644\u0623\u0637\u0648\u0627\u0631 \u0627\u0644\u062b\u0644\u0627\u062b\u0629\u060c \u0648\u0627\u0644\u0630\u064a \u062a\u0645 \u062a\u062c\u0641\u064a\u0641 \u0639\u0632\u0644\u062a\u0647 \u0627\u0644\u0648\u0631\u0642\u064a\u0629 \u0648\u0641\u0642\u064b\u0627 \u0644\u0644\u0645\u062a\u0637\u0644\u0628\u0627\u062a (\u0631\u0637\u0648\u0628\u0629 0.5% \u0623\u0648 \u0623\u0642\u0644) \u0648\u0642\u062f \u062e\u0636\u0639 \u0644\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0641\u0642\u062f\u0627\u0646 \u0627\u0644\u062d\u0645\u0644 \u0627\u0644\u062a\u064a \u062a\u0624\u0643\u062f \u0627\u0644\u0645\u0633\u062a\u0648\u064a\u0627\u062a \u0627\u0644\u0645\u0636\u0645\u0648\u0646\u0629 \u0636\u0645\u0646 3%\u060c \u0633\u064a\u0633\u062a\u0645\u0631 \u0641\u064a \u0627\u0644\u0639\u0645\u0644 \u0644\u0633\u0646\u0648\u0627\u062a \u0639\u062f\u064a\u062f\u0629. \u0639\u0644\u0649 \u0627\u0644\u0639\u0643\u0633 \u0645\u0646 \u0630\u0644\u0643\u060c \u0641\u0625\u0646 \u0627\u0644\u0645\u062d\u0648\u0644 \u0627\u0644\u0630\u064a \u062a\u0645 \u062a\u0635\u0646\u064a\u0639\u0647 \u0645\u0646 \u0642\u0628\u0644 \u0634\u0631\u0643\u0627\u062a \u063a\u064a\u0631 \u0645\u0628\u0627\u0644\u064a\u0629 \u0648\u0644\u0645 \u064a\u062a\u0645 \u062a\u062c\u0641\u064a\u0641\u0647 \u0628\u0634\u0643\u0644 \u0635\u062d\u064a\u062d \u0648\u0644\u0645 \u064a\u062a\u0645 \u062a\u062b\u0628\u064a\u062a \u0646\u0648\u0627\u062a\u0647 \u0633\u064a\u062a\u0648\u0642\u0641 \u0639\u0646 \u0627\u0644\u0639\u0645\u0644 \u0628\u0639\u062f \u0623\u0631\u0628\u0639 \u0633\u0646\u0648\u0627\u062a \u0641\u0642\u0637 \u0645\u0646 \u0627\u0644\u062a\u0634\u063a\u064a\u0644. \u062a\u0636\u0645\u0646 \u0625\u062f\u0627\u0631\u0629 \u062c\u0648\u062f\u0629 \u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u0637\u0627\u0642\u0629 \u062a\u062c\u0645\u064a\u0639 \u062b\u0644\u0627\u062b\u0629 \u0623\u0646\u0648\u0627\u0639 \u0645\u062e\u062a\u0644\u0641\u0629 \u0645\u0646 \u0627\u0644\u0645\u0648\u0627\u062f (\u0627\u0644\u0641\u0648\u0644\u0627\u0630\u060c \u0627\u0644\u0646\u062d\u0627\u0633\u060c \u0623\u0648 \u0627\u0644\u0648\u0631\u0642) \u0641\u064a \u0645\u062d\u0648\u0644 \u0645\u0648\u062b\u0648\u0642 \u0644\u0644\u063a\u0627\u064a\u0629.<\/p>\n<p>\u0627\u0644\u0647\u062f\u0641 \u0627\u0644\u0631\u0626\u064a\u0633\u064a \u0645\u0646 \u0647\u0630\u0647 \u0627\u0644\u0645\u0642\u0627\u0644\u0629 \u0647\u0648 \u0634\u0631\u062d \u0645\u0648\u0627\u0642\u0639 \u0646\u0642\u0627\u0637 \u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u0639\u0645\u0644\u064a\u0627\u062a \u0625\u0646\u062a\u0627\u062c \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a - \u0648\u0647\u0630\u0647 \u062a\u0634\u0645\u0644 \u0641\u062d\u0635 \u0627\u0644\u0645\u0648\u0627\u062f \u0627\u0644\u0648\u0627\u0631\u062f\u0629\u060c \u0648\u062a\u062c\u0645\u064a\u0639 \u0627\u0644\u0646\u0648\u0649 \u0648\u0627\u0644\u0644\u0641\u0627\u0626\u0641\u060c \u0648\u0627\u0644\u062a\u062c\u0641\u064a\u0641 \u0628\u0627\u0644\u0641\u0631\u0627\u063a \u0648\u0645\u0644\u0621 \u0627\u0644\u0632\u064a\u062a \u0644\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0628\u0627\u0644\u0625\u0636\u0627\u0641\u0629 \u0625\u0644\u0649 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0627\u0644\u0646\u0647\u0627\u0626\u064a\u0629 \u0644\u0644\u0645\u0646\u062a\u062c\u0627\u062a.<\/p>\n<blockquote><p>\u0627\u0644\u0625\u062c\u0627\u0628\u0629 \u0627\u0644\u0642\u0635\u064a\u0631\u0629: \u062a\u062a\u0643\u0648\u0646 \u0639\u0645\u0644\u064a\u0629 \u0645\u0631\u0627\u0642\u0628\u0629 \u0627\u0644\u062c\u0648\u062f\u0629 \u0644\u062a\u0635\u0646\u064a\u0639 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0645\u0646 \u062e\u0645\u0633 \u0646\u0642\u0627\u0637 \u0631\u0626\u064a\u0633\u064a\u0629 \u0644\u0645\u0631\u0627\u0642\u0628\u0629 \u0627\u0644\u062c\u0648\u062f\u0629: \u0641\u062d\u0635 \u0627\u0644\u0645\u0648\u0627\u062f \u0627\u0644\u062e\u0627\u0645\u060c \u0625\u0646\u062a\u0627\u062c \u0627\u0644\u0646\u0648\u0627\u0629 \u0648\u0627\u0644\u0644\u0641\u060c \u0627\u0644\u062a\u062c\u0641\u064a\u0641 \u0628\u0627\u0644\u0641\u0631\u0627\u063a \u0648\u0627\u0645\u062a\u0635\u0627\u0635 \u0627\u0644\u0632\u064a\u062a \u0644\u0644\u0645\u0644\u0641\u060c \u062a\u062c\u0645\u064a\u0639 \u0627\u0644\u0645\u062d\u0648\u0644\u060c \u0648\u0627\u062e\u062a\u0628\u0627\u0631 \u0642\u0628\u0648\u0644 \u0627\u0644\u0645\u0635\u0646\u0639 \u0648\u0641\u0642\u064b\u0627 \u0644\u0645\u0639\u064a\u0627\u0631 IEC 60076-1. \u062a\u0634\u0645\u0644 \u0627\u0644\u0646\u0642\u0627\u0637 \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629 \u0644\u0645\u0631\u0627\u0642\u0628\u0629 \u0627\u0644\u062c\u0648\u062f\u0629 \u0646\u0633\u0628\u0629 \u0644\u0641\u0627\u062a \u0627\u0644\u0645\u062d\u0648\u0644 \u0636\u0645\u0646 \u00b10.5%\u060c \u0648\u0627\u0646\u062d\u0631\u0627\u0641 \u0646\u0633\u0628\u0629 \u0627\u0646\u062e\u0641\u0627\u0636 \u0627\u0644\u062c\u0647\u062f \u0623\u0642\u0644 \u0645\u0646 2%\u060c \u0648\u0641\u0642\u062f\u0627\u0646 \u0627\u0644\u062d\u0645\u0644 \u0648\u0641\u0642\u062f\u0627\u0646 \u0627\u0644\u062d\u0645\u0644 \u0648\u0641\u0642\u064b\u0627 \u0644\u0645\u0639\u064a\u0627\u0631 IEC 60076-1 (\u00b110% \u0625\u0644\u0649 +15%).<\/p><\/blockquote>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-10841\" src=\"https:\/\/subian-electric.com\/wp-content\/uploads\/2026\/08\/Quality-Control-Points-And-Optimization-Paths-Of-Power-Transformer-Manufacturing-Process.webp\" alt=\"Quality Control Points And Optimization Paths Of Power Transformer Manufacturing Process\" width=\"1448\" height=\"1086\" \/><\/p>\n<hr \/>\n<h2 id=\"what-is\">\u0645\u0627 \u0647\u064a \u0645\u0631\u0627\u0642\u0628\u0629 \u062c\u0648\u062f\u0629 \u062a\u0635\u0646\u064a\u0639 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a\u061f<\/h2>\n<p>\u0641\u064a \u062a\u0635\u0646\u064a\u0639 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a\u060c \u062a\u0639\u0646\u064a \u0645\u0631\u0627\u0642\u0628\u0629 \u0627\u0644\u062c\u0648\u062f\u0629 \u0633\u0644\u0633\u0644\u0629 \u0645\u0646 \u0627\u0644\u0641\u062d\u0648\u0635\u0627\u062a \u0627\u0644\u0645\u062e\u0637\u0637 \u0644\u0647\u0627\u060c \u0648\u0627\u0644\u0642\u064a\u0627\u0633\u0627\u062a\u060c \u0648\u0646\u0642\u0627\u0637 \u0627\u0644\u062a\u0648\u0642\u0641 \u0627\u0644\u062a\u064a \u062a\u0636\u0645\u0646 \u0623\u0646 \u0627\u0644\u0648\u062d\u062f\u0629 \u0633\u062a\u0643\u0648\u0646 \u0642\u0627\u062f\u0631\u0629 \u0639\u0644\u0649 \u0627\u0644\u0643\u0641\u0627\u0621\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0648\u0627\u0644\u062d\u0631\u0627\u0631\u064a\u0629 \u0648\u0627\u0644\u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629 \u0648\u0641\u0642\u064b\u0627 \u0644\u0639\u0645\u0631 \u062a\u0635\u0645\u064a\u0645 \u0644\u0627 \u064a\u0642\u0644 \u0639\u0646 25-40 \u0639\u0627\u0645\u064b\u0627. \u0645\u0646 \u0627\u0644\u0645\u0647\u0645 \u0627\u0644\u062a\u0623\u0643\u064a\u062f \u0639\u0644\u0649 \u0623\u0646 \u0645\u0631\u0627\u0642\u0628\u0629 \u0627\u0644\u062c\u0648\u062f\u0629 \u0644\u064a\u0633\u062a \u0647\u064a \u0646\u0641\u0633\u0647\u0627 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631. \u064a\u0643\u0634\u0641 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0639\u0646 \u0627\u0644\u0639\u064a\u0648\u0628\u060c \u0628\u064a\u0646\u0645\u0627 \u062a\u0645\u0646\u0639 \u0645\u0631\u0627\u0642\u0628\u0629 \u0627\u0644\u062c\u0648\u062f\u0629 \u062d\u062f\u0648\u062b\u0647\u0627. \u0648\u0628\u0627\u0644\u062a\u0627\u0644\u064a\u060c \u0641\u0625\u0646 \u0627\u0644\u0645\u0635\u0646\u0639 \u0627\u0644\u0630\u064a \u0644\u062f\u064a\u0647 \u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0646\u0647\u0627\u0626\u064a\u0629 \u0645\u0645\u062a\u0627\u0632\u0629 \u0648\u0644\u0643\u0646 \u0644\u062f\u064a\u0647 \u0645\u0631\u0627\u0642\u0628\u0629 \u0639\u0645\u0644\u064a\u0629 \u0636\u0639\u064a\u0641\u0629 \u064a\u062d\u062f\u062f \u0628\u0628\u0633\u0627\u0637\u0629 \u0627\u0644\u0645\u0634\u0643\u0644\u0627\u062a \u0641\u064a \u0646\u0647\u0627\u064a\u0629 \u0627\u0644\u0639\u0645\u0644\u064a\u0629\u060c \u0639\u0646\u062f\u0645\u0627 \u062a\u0643\u0648\u0646 \u0627\u0644\u062a\u0635\u062d\u064a\u062d\u0627\u062a \u0627\u0644\u0623\u0643\u062b\u0631 \u062a\u0643\u0644\u0641\u0629. \u064a\u0646\u062a\u062c \u0627\u0644\u0645\u0635\u0646\u0639 \u0627\u0644\u0630\u064a \u0644\u062f\u064a\u0647 \u0645\u0631\u0627\u0642\u0628\u0629 \u0639\u0645\u0644\u064a\u0629 \u0635\u0627\u0631\u0645\u0629 \u0645\u0646\u062a\u062c\u0627\u062a \u0645\u0633\u062a\u0642\u0631\u0629 \u0628\u062a\u0643\u0627\u0644\u064a\u0641 \u0647\u062f\u0631 \u0645\u0646\u062e\u0641\u0636\u0629\u060c \u0648\u0644\u0647\u0630\u0627 \u0627\u0644\u0633\u0628\u0628 \u062a\u0639\u062a\u0628\u0631 \u0623\u0641\u0636\u0644 \u0627\u0644\u0634\u0631\u0643\u0627\u062a \u0627\u0644\u0645\u0635\u0646\u0639\u0629 \u0627\u0644\u0635\u064a\u0646\u064a\u0629 \u0648\u0627\u0644\u062f\u0648\u0644\u064a\u0629 \u0645\u0631\u0627\u0642\u0628\u0629 \u0627\u0644\u062c\u0648\u062f\u0629 \u0643\u062a\u0643\u0646\u0648\u0644\u0648\u062c\u064a\u0627 \u0625\u0646\u062a\u0627\u062c \u0628\u062f\u0644\u0627\u064b \u0645\u0646 \u0642\u0633\u0645 \u0627\u0644\u0641\u062d\u0635 \u0627\u0644\u0646\u0647\u0627\u0626\u064a.<\/p>\n<p>\u0623\u0633\u0627\u0633 \u0627\u0644\u0645\u0639\u0627\u064a\u064a\u0631 \u0647\u0648 IEC 60076-1 (\u0627\u0644\u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u0639\u0627\u0645\u0629 \u0648\u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631) \u0645\u0643\u0645\u0644\u064b\u0627 \u0628\u0640 IEC 60076-3 (\u0645\u0633\u062a\u0648\u064a\u0627\u062a \u0627\u0644\u0639\u0632\u0644)\u060c IEC 60076-5 (\u062f\u0631\u062c\u0629 \u0627\u0644\u0645\u0642\u0627\u0648\u0645\u0629 \u0644\u0644\u062f\u0648\u0627\u0626\u0631 \u0627\u0644\u0642\u0635\u064a\u0631\u0629) \u0648 IEC 60076-10 (\u0645\u0633\u062a\u0648\u0649 \u0627\u0644\u0635\u0648\u062a). \u064a\u062c\u0628 \u0623\u0646 \u064a\u062a\u0645 \u0625\u0628\u0644\u0627\u063a \u0627\u0644\u0645\u0634\u062a\u0631\u064a\u0646 \u0623\u064a\u0636\u064b\u0627 \u0628\u0623\u0646 \u0627\u0644\u063a\u0627\u0644\u0628\u064a\u0629 \u0627\u0644\u0639\u0638\u0645\u0649 \u0645\u0646 \u0627\u0644\u0645\u0635\u0627\u0646\u0639 \u0627\u0644\u0645\u0648\u062b\u0648\u0642\u0629 \u062a\u0633\u062a\u062e\u062f\u0645 \u0646\u0638\u0627\u0645 \u0625\u062f\u0627\u0631\u0629 \u0627\u0644\u062c\u0648\u062f\u0629 ISO 9001 \u0628\u0627\u0644\u0625\u0636\u0627\u0641\u0629 \u0625\u0644\u0649 \u0645\u0639\u0627\u064a\u064a\u0631 \u0627\u0644\u0645\u0646\u062a\u062c.<\/p>\n<h2 id=\"process\">\u0639\u0645\u0644\u064a\u0629 \u0627\u0644\u062a\u0635\u0646\u064a\u0639: \u062d\u064a\u062b \u064a\u062a\u0645 \u0635\u0646\u0639 \u0627\u0644\u062c\u0648\u062f\u0629 \u0623\u0648 \u0641\u0642\u062f\u0627\u0646\u0647\u0627<\/h2>\n<p>\u064a\u062a\u0636\u0645\u0646 \u0627\u0644\u0645\u062d\u0648\u0644 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0627\u0644\u0645\u063a\u0645\u0648\u0631 \u0628\u0627\u0644\u0632\u064a\u062a \u0627\u0644\u0642\u064a\u0627\u0633\u064a \u062d\u0648\u0627\u0644\u064a 10 \u0645\u0631\u0627\u062d\u0644 \u0648\u0644\u0643\u0644 \u0645\u0631\u062d\u0644\u0629 \u0646\u0645\u0637 \u0641\u0634\u0644 \u062e\u0627\u0635 \u0628\u0647\u0627 \u0625\u0630\u0627 \u062d\u062f\u062b \u062e\u0637\u0623 \u0645\u0627 \u0641\u064a \u0627\u0644\u0639\u0645\u0644\u064a\u0629. \u064a\u062a\u0645 \u0642\u0637\u0639 \u0648\u062a\u0643\u062f\u064a\u0633 \u0634\u0631\u0627\u0626\u062d \u0627\u0644\u0642\u0644\u0628 \u0639\u0646\u062f \u0639\u0627\u0645\u0644 \u062a\u0643\u062f\u064a\u0633 \u0648\u0636\u063a\u0637 \u062a\u062b\u0628\u064a\u062a \u0645\u062a\u062d\u0643\u0645 \u0641\u064a\u0647\u060c \u0648\u0625\u0630\u0627 \u0643\u0627\u0646\u062a \u0645\u0634\u062f\u0648\u062f\u0629 \u0628\u0634\u0643\u0644 \u0632\u0627\u0626\u062f \u0623\u0648 \u0643\u0627\u0646\u062a \u0647\u0646\u0627\u0643 \u062a\u0622\u0643\u0644 \u0628\u064a\u0646 \u0627\u0644\u0634\u0631\u0627\u0626\u062d\u060c \u0641\u0625\u0646 \u062e\u0633\u0627\u0626\u0631 \u0627\u0644\u062d\u0645\u0644 \u0627\u0644\u062e\u0627\u0644\u064a \u062a\u0632\u062f\u0627\u062f \u0648\u062a\u0638\u0647\u0631 \u0646\u0642\u0627\u0637 \u0633\u0627\u062e\u0646\u0629 \u0639\u0644\u0649 \u0627\u0644\u0642\u0644\u0628. \u064a\u062a\u0645 \u0625\u0646\u0634\u0627\u0621 \u0627\u0644\u0644\u0641\u0627\u0626\u0641 \u0645\u0646 \u0623\u0633\u0644\u0627\u0643 \u0627\u0644\u0646\u062d\u0627\u0633 \u0623\u0648 \u0627\u0644\u0623\u0644\u0645\u0646\u064a\u0648\u0645 \u0627\u0644\u062a\u064a \u062a\u0643\u0648\u0646 \u0623\u064a\u0636\u064b\u0627 \u062a\u062d\u062a \u062a\u0648\u062a\u0631 \u0645\u062a\u062d\u0643\u0645 \u0641\u064a\u0647 \u0648\u0639\u0632\u0644 \u0637\u0628\u0642\u064a\u060c \u0648\u064a\u0645\u0643\u0646 \u0623\u0646 \u062a\u0624\u062f\u064a \u0648\u0631\u0642\u0629 \u0628\u064a\u0646\u064a\u0629 \u063a\u064a\u0631 \u0645\u062a\u0633\u0627\u0648\u064a\u0629 \u0648\u0627\u062d\u062f\u0629 \u0625\u0644\u0649 \u062a\u0641\u0631\u064a\u063a\u0627\u062a \u062c\u0632\u0626\u064a\u0629. \u064a\u062a\u0645 \u062a\u062c\u0641\u064a\u0641 \u0627\u0644\u062c\u0632\u0621 \u0627\u0644\u0646\u0634\u0637 \u0641\u064a \u063a\u0631\u0641\u0629 \u0641\u0631\u0627\u063a \u0644\u0644\u062a\u062e\u0644\u0635 \u0645\u0646 \u0627\u0644\u0631\u0637\u0648\u0628\u0629\u060c \u0648\u0647\u0648 \u0623\u0648\u0644 \u0648\u0623\u0647\u0645 \u0646\u0642\u0637\u0629 \u062a\u0641\u062a\u064a\u0634 \u062c\u0648\u062f\u0629 \u0641\u064a \u0627\u0644\u0639\u0645\u0644\u064a\u0629 \u0627\u0644\u0645\u0639\u0646\u064a\u0629. \u0628\u0639\u062f \u0630\u0644\u0643\u060c \u064a\u062a\u0645 \u0625\u0646\u0634\u0627\u0621 \u0641\u0631\u0627\u063a \u0641\u064a \u0627\u0644\u062e\u0632\u0627\u0646 \u0648\u0645\u0644\u0624\u0647 \u0628\u0632\u064a\u062a \u0645\u0646\u0632\u0648\u0639 \u0627\u0644\u063a\u0627\u0632 \u0648\u0645\u062c\u0641\u0641\u060c \u0648\u0622\u062e\u0631 \u062c\u0632\u0621 \u0645\u0646 \u0627\u0644\u0639\u0645\u0644\u064a\u0629 \u0647\u0648 \u062a\u0646\u0641\u064a\u0630 \u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0627\u0644\u0645\u0635\u0646\u0639.<\/p>\n<p>\u0627\u0644\u0646\u0642\u0644 \u0647\u0648 \u0623\u064a\u0636\u064b\u0627 \u0646\u0642\u0637\u0629 \u062a\u0641\u062a\u064a\u0634 \u062c\u0648\u062f\u0629\u060c \u062d\u064a\u062b \u064a\u0645\u0643\u0646 \u0623\u0646 \u064a\u062a\u0639\u0631\u0636 \u0627\u0644\u0645\u062d\u0648\u0644 \u0644\u0623\u0636\u0631\u0627\u0631 \u0646\u062a\u064a\u062c\u0629 \u0627\u0644\u0635\u062f\u0645\u0627\u062a \u0648\u0627\u0644\u0627\u0646\u062d\u0631\u0627\u0641. \u0627\u0644\u062d\u0644 \u0644\u0644\u0645\u0634\u0643\u0644\u0629 \u0647\u0648 IEC 60076-11 \u0627\u0644\u0630\u064a \u064a\u0642\u062a\u0631\u062d \u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0645\u0633\u062c\u0644\u0627\u062a \u0627\u0644\u0635\u062f\u0645\u0627\u062a \u0648\u0627\u0644\u0627\u0646\u062d\u0631\u0627\u0641 \u0641\u064a \u0627\u0644\u062a\u0648\u0631\u0628\u064a\u0646\u0627\u062a \u0627\u0644\u0643\u0628\u064a\u0631\u0629. \u0633\u064a\u062c\u062f \u0627\u0644\u0642\u0627\u0631\u0626 \u0623\u0641\u0636\u0644 \u0646\u0642\u0627\u0637 \u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u0627\u0644\u0641\u0642\u0631\u0627\u062a \u0627\u0644\u062a\u0627\u0644\u064a\u0629.<\/p>\n<table>\n<thead>\n<tr>\n<th>\u0645\u0631\u062d\u0644\u0629 \u0627\u0644\u0639\u0645\u0644\u064a\u0629<\/th>\n<th>\u0637\u0631\u064a\u0642\u0629 \u0645\u0631\u0627\u0642\u0628\u0629 \u0627\u0644\u062c\u0648\u062f\u0629<\/th>\n<th>\u062a\u0643\u0644\u0641\u0629 \u0627\u0644\u0641\u0634\u0644 \u0625\u0630\u0627 \u0644\u0645 \u064a\u062a\u0645 \u0641\u062d\u0635\u0647\u0627<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u0627\u0633\u062a\u0644\u0627\u0645 \u0627\u0644\u0645\u0648\u0627\u062f<\/td>\n<td>\u0634\u0647\u0627\u062f\u0627\u062a \u0627\u0644\u0645\u0648\u0631\u062f + \u0627\u062e\u062a\u0628\u0627\u0631 \u0639\u0634\u0648\u0627\u0626\u064a<\/td>\n<td>\u0645\u0646\u062e\u0641\u0636\u0629 - \u062a\u0645 \u0627\u0643\u062a\u0634\u0627\u0641\u0647\u0627 \u0645\u0628\u0643\u0631\u064b\u0627<\/td>\n<\/tr>\n<tr>\n<td>\u0642\u0637\u0639\/\u062a\u0643\u062f\u064a\u0633 \u0627\u0644\u0642\u0644\u0628<\/td>\n<td>\u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u062d\u062c\u0645 \u0627\u0644\u0627\u0642\u062a\u0631\u0627\u0636\u060c \u0641\u062d\u0635 \u0639\u0627\u0645\u0644 \u0627\u0644\u062a\u0643\u062f\u064a\u0633<\/td>\n<td>\u0645\u062a\u0648\u0633\u0637\u0629 - \u062e\u0633\u0627\u0631\u0629 \u062d\u0645\u0644 \u062e\u0627\u0644\u064a \u0623\u0639\u0644\u0649<\/td>\n<\/tr>\n<tr>\n<td>\u0628\u0646\u0627\u0621 \u0627\u0644\u0644\u0641\u0627\u0626\u0641<\/td>\n<td>\u0639\u062f\u062f \u0627\u0644\u0644\u0641\u0627\u062a\u060c \u0641\u062d\u0635 \u0627\u0644\u062a\u0648\u062a\u0631\u060c \u0641\u062d\u0635 \u0627\u0644\u0645\u0642\u0627\u0648\u0645\u0629<\/td>\n<td>\u0639\u0627\u0644\u064a\u0629 - \u0644\u0641\u0627\u062a \u0642\u0635\u064a\u0631\u0629\u060c \u0646\u0642\u0627\u0637 \u0633\u0627\u062e\u0646\u0629<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u062a\u062c\u0641\u064a\u0641 \u0628\u0627\u0644\u0641\u0631\u0627\u063a<\/td>\n<td>\u0646\u0642\u0637\u0629 \u0646\u0647\u0627\u064a\u0629 \u0627\u0644\u0631\u0637\u0648\u0628\u0629\u060c PI \u0628\u0639\u062f \u0627\u0644\u0645\u0644\u0621<\/td>\n<td>\u0639\u0627\u0644\u064a\u0629 \u062c\u062f\u064b\u0627 - \u0641\u0634\u0644 \u0645\u0628\u0643\u0631<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u062a\u062c\u0645\u064a\u0639 \u0648\u0627\u0644\u062a\u0639\u0628\u0626\u0629<\/td>\n<td>\u0633\u062c\u0644\u0627\u062a \u0627\u0644\u0639\u0632\u0645\u060c \u0641\u062d\u0635 \u0627\u0644\u0648\u0635\u0644\u0627\u062a<\/td>\n<td>\u0645\u062a\u0648\u0633\u0637\u0629 - \u062a\u0633\u0631\u064a\u0628\u0627\u062a\u060c \u0623\u062c\u0632\u0627\u0621 \u0641\u0636\u0641\u0627\u0636\u0629<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0645\u0635\u0646\u0639<\/td>\n<td>\u0628\u0637\u0627\u0631\u064a\u0629 \u0631\u0648\u062a\u064a\u0646\u064a\u0629 IEC 60076-1<\/td>\n<td>\u0639\u0627\u0644\u064a\u0629 - \u0627\u0646\u062d\u0631\u0627\u0641\u0627\u062a \u0636\u0645\u0627\u0646 \u0645\u0641\u0642\u0648\u062f\u0629<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u062a\u0639\u0628\u0626\u0629 \u0648\u0627\u0644\u0646\u0642\u0644<\/td>\n<td>\u0645\u0633\u062c\u0644\u0627\u062a \u0627\u0644\u0635\u062f\u0645\u0627\u062a\/\u0627\u0644\u0627\u0646\u062d\u0631\u0627\u0641\u060c \u062e\u0637\u0629 \u0627\u0644\u062a\u0639\u0627\u0645\u0644<\/td>\n<td>\u0639\u0627\u0644\u064a\u0629 - \u0623\u0636\u0631\u0627\u0631 \u0627\u0644\u0646\u0642\u0644<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2 id=\"incoming\">\u0646\u0642\u0637\u0629 \u0627\u0644\u062a\u062d\u0643\u0645 1: \u0641\u062d\u0635 \u0627\u0644\u0645\u0648\u0627\u062f \u0627\u0644\u0648\u0627\u0631\u062f\u0629<\/h2>\n<table>\n<thead>\n<tr>\n<th>\u0627\u0644\u0645\u0648\u0627\u062f<\/th>\n<th>\u0637\u0631\u064a\u0642\u0629 \u0627\u0644\u0641\u062d\u0635<\/th>\n<th>\u0645\u0639\u0627\u064a\u064a\u0631 \u0627\u0644\u0642\u0628\u0648\u0644 \u0627\u0644\u0646\u0645\u0648\u0630\u062c\u064a\u0629<\/th>\n<th>\u0639\u0648\u0627\u0642\u0628 \u0627\u0644\u0645\u0648\u0627\u062f \u0627\u0644\u0631\u062f\u064a\u0626\u0629<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u0641\u0648\u0644\u0627\u0630 \u0633\u064a\u0644\u064a\u0643\u0648\u0646 \u0645\u0648\u062c\u0647 \u0644\u0644\u062d\u0628\u064a\u0628\u0627\u062a<\/td>\n<td>\u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u062e\u0635\u0627\u0626\u0635 \u0627\u0644\u0645\u063a\u0646\u0627\u0637\u064a\u0633\u064a\u0629 \u0648\u0641\u0642\u064b\u0627 \u0644\u0640 ASTM A876 \/ IEC 60404<\/td>\n<td>\u062e\u0633\u0627\u0631\u0629 \u0625\u062c\u0645\u0627\u0644\u064a\u0629 \u0645\u062d\u062f\u062f\u0629 \u2264 \u062d\u062f \u0627\u0644\u0643\u062a\u0627\u0644\u0648\u062c\u061b \u0627\u0644\u0637\u0644\u0627\u0621 \u0633\u0644\u064a\u0645<\/td>\n<td>\u062e\u0633\u0627\u0631\u0629 \u062d\u0645\u0644 \u062e\u0627\u0644\u064a \u0623\u0639\u0644\u0649\u060c \u0641\u0626\u0629 \u0643\u0641\u0627\u0621\u0629 \u0623\u0642\u0644<\/td>\n<\/tr>\n<tr>\n<td>\u0645\u0648\u0635\u0644 \u0646\u062d\u0627\u0633\u064a \/ \u0623\u0644\u0645\u0646\u064a\u0648\u0645<\/td>\n<td>\u0641\u062d\u0635 \u0627\u0644\u0645\u0642\u0627\u0648\u0645\u0629 \u0648\u0627\u0644\u0623\u0628\u0639\u0627\u062f<\/td>\n<td>\u2265 99.9% \u0645\u0648\u0635\u0644\u064a\u0629 \u0627\u0644\u0646\u062d\u0627\u0633\u061b \u062a\u062d\u0645\u0644 \u0627\u0644\u0642\u0637\u0631 \u00b10.5%<\/td>\n<td>\u062e\u0633\u0627\u0631\u0629 \u062d\u0645\u0644 \u0623\u0639\u0644\u0649\u060c \u0646\u0642\u0627\u0637 \u0633\u0627\u062e\u0646\u0629<\/td>\n<\/tr>\n<tr>\n<td>\u0648\u0631\u0642 \u0639\u0627\u0632\u0644 \u0648\u0633\u0628\u0627\u0626\u0643 \u0645\u0636\u063a\u0648\u0637\u0629<\/td>\n<td>\u0627\u0644\u0643\u062b\u0627\u0641\u0629\u060c \u0642\u0648\u0629 \u0627\u0644\u0634\u062f\u060c \u0645\u062d\u062a\u0648\u0649 \u0627\u0644\u0631\u0637\u0648\u0628\u0629<\/td>\n<td>\u0643\u062b\u0627\u0641\u0629 0.9\u20131.2 \u062c\u0631\u0627\u0645\/\u0633\u0645\u00b3\u061b \u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0648\u0641\u0642\u064b\u0627 \u0644\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a<\/td>\n<td>\u062e\u0637\u0631 \u0627\u0644\u062a\u0641\u0631\u064a\u063a\u060c \u0636\u0639\u0641 \u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a<\/td>\n<\/tr>\n<tr>\n<td>\u0632\u064a\u062a \u0639\u0627\u0632\u0644<\/td>\n<td>Dielectric strength (IEC 60156), water content, DGA<\/td>\n<td>BDV \u2265 40 kV, water &lt; 20 ppm (new oil)<\/td>\n<td>Lower withstand, accelerated aging<\/td>\n<\/tr>\n<tr>\n<td>Bushings &amp; tap changers<\/td>\n<td>Visual, insulation resistance, tan delta, gas tightness<\/td>\n<td>Per supplier test certificates and spot re-test<\/td>\n<td>Bushing flashover, OLTC failure<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Serious manufacturing companies have close oversight of the materials they bring in based on supply specifications and not just on brand names. For instance, steel coils vary in composition and quality from one coil to another even when coming from the same manufacturer. This means that a company that keeps track of every reel and chooses steel based on real characteristics of the metal rather than a stamp is already achieving quality at the lowest cost.<\/p>\n<h2 id=\"core-winding\">Control Points 2\u20133: Core &amp; Winding Fabrication<\/h2>\n<table>\n<thead>\n<tr>\n<th>Stage<\/th>\n<th>Key Checks<\/th>\n<th>\u0645\u0639\u0627\u064a\u064a\u0631 \u0627\u0644\u0642\u0628\u0648\u0644 \u0627\u0644\u0646\u0645\u0648\u0630\u062c\u064a\u0629<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Core cutting &amp; stacking<\/td>\n<td>Stacking factor, burr height, clamping pressure, lamination insulation<\/td>\n<td>Stacking factor \u2265 0.95; burr &lt; 0.02 mm; no shorted laminations<\/td>\n<\/tr>\n<tr>\n<td>Core assembly &amp; banding<\/td>\n<td>Clamping torque, core ground connection, bolt insulation<\/td>\n<td>Single-point core ground; insulation resistance between laminations &gt; 100 M\u03a9<\/td>\n<\/tr>\n<tr>\n<td>Winding conductor &amp; insulation<\/td>\n<td>Conductor tension, paper wrap continuity, layer insulation placement<\/td>\n<td>No bare conductor exposure; continuous layer insulation<\/td>\n<\/tr>\n<tr>\n<td>Winding disc \/ layer build<\/td>\n<td>Turn count, transposition, cooling duct alignment<\/td>\n<td>Turn count verified against design; ducts clear and uniform<\/td>\n<\/tr>\n<tr>\n<td>Coil pressing &amp; clamping<\/td>\n<td>Axial pressure, coil height consistency<\/td>\n<td>Pressure within design window; height variation &lt; 1 mm across phases<\/td>\n<\/tr>\n<tr>\n<td>Tap changer &amp; lead connections<\/td>\n<td>Brazing\/soldering quality, insulation distance, torque<\/td>\n<td>Low-resistance joints; verified clearances per insulation level<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>There are two important aspects related to this. First and foremost, winding resistance imbalance between the phases must be maintained at the time of manufacturing to ideally less than 2%. Otherwise, an improper transposition of a parallel conductor system appears in the form of circulating currents and hot spots in the system operating under the load. Another thing is core clamping pressure which should be neither too loose nor too tight. A loose configuration results in a humming core, while a tight one causes insulation of the laminations to get crushed. The problem here can be solved through the process of measurement in the course of production.<\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-10842\" src=\"https:\/\/subian-electric.com\/wp-content\/uploads\/2026\/08\/Control-Point-1-5.webp\" alt=\"Control Point 1-5\" width=\"1448\" height=\"1086\" \/><\/p>\n<h2 id=\"drying\">Control Point 4: Vacuum Drying &amp; Oil Impregnation<\/h2>\n<p>Moisture is the main menace for a transformer, and it is either eliminated or let into the active winding in the course of the drying and oil-filling operation. Paper is dried in a vacuum oven (at temperature usually reaching a minimum of 100\u2013130 \u00b0C with distribution units and even higher temperatures for large units in deep vacuum below 50 Pa or 0.5 mb) until moisture drops to less than 0.5% (in mass fraction), having its quality verified by Karl Fischer or dew point measurement. After that, oil is filled into the tank and the impregnation process is completed without any bubbles being left inside the paper \u2014 all bubbles are dangerous sources of potential discharge.<\/p>\n<p>This process is usually rushed when the drying time is reduced. A properly dried and impregnated transformer usually takes several days to dry, e.g. a 10 MVA transformer takes at least 2\u20134 days to dry in a drying process and 1 day for vacuum filling. Factories that hurry with this process save money now but will face problems later. The correctness of the drying process can be checked using insulation resistance and polarization index measurements after the filling process is completed. A polarization index above 2.0 ensures that paper is dry, whereas a value below 1.5 means that there is humidity left.<\/p>\n<h2 id=\"testing\">Control Point 5: Factory Acceptance Testing<\/h2>\n<table>\n<thead>\n<tr>\n<th>\u0627\u062e\u062a\u0628\u0627\u0631<\/th>\n<th>\u0627\u0644\u0645\u0631\u062c\u0639 \u0627\u0644\u0642\u064a\u0627\u0633\u064a<\/th>\n<th>\u0645\u0639\u0627\u064a\u064a\u0631 \u0627\u0644\u0642\u0628\u0648\u0644 \u0627\u0644\u0646\u0645\u0648\u0630\u062c\u064a\u0629<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Turn ratio test (all taps)<\/td>\n<td>IEC 60076-1<\/td>\n<td>Within \u00b10.5% of design ratio<\/td>\n<\/tr>\n<tr>\n<td>\u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u0645\u0644\u0641\u0627\u062a<\/td>\n<td>IEC 60076-1<\/td>\n<td>Phase imbalance \u2264 2%; corrected to reference temperature<\/td>\n<\/tr>\n<tr>\n<td>Insulation resistance \/ PI<\/td>\n<td>IEEE 43 \/ IEC 60076-1<\/td>\n<td>PI \u2265 2.0 for oil-immersed units<\/td>\n<\/tr>\n<tr>\n<td>\u0641\u0642\u062f \u0627\u0644\u0637\u0627\u0642\u0629 \u0628\u062f\u0648\u0646 \u062d\u0645\u0644 \u0648\u0627\u0644\u062a\u064a\u0627\u0631<\/td>\n<td>IEC 60076-1<\/td>\n<td>Within tolerance: loss +15% (and \u221210%) on guaranteed value per IEC<\/td>\n<\/tr>\n<tr>\n<td>\u0641\u0642\u062f \u0627\u0644\u0637\u0627\u0642\u0629 \u0648\u0627\u0644\u0645\u0642\u0627\u0648\u0645\u0629<\/td>\n<td>IEC 60076-1<\/td>\n<td>Load loss within +15%; impedance within \u00b17.5%<\/td>\n<\/tr>\n<tr>\n<td>Dielectric tests (LI, AC, applied)<\/td>\n<td>IEC 60076-3<\/td>\n<td>No flashover or breakdown at specified levels<\/td>\n<\/tr>\n<tr>\n<td>\u0642\u064a\u0627\u0633 \u0627\u0644\u062a\u0641\u0631\u064a\u063a \u0627\u0644\u062c\u0632\u0626\u064a<\/td>\n<td>IEC 60270<\/td>\n<td>Typically &lt; 100 pC at 1.1\u00d7 rated voltage for HV units<\/td>\n<\/tr>\n<tr>\n<td>Temperature rise test<\/td>\n<td>IEC 60076-2<\/td>\n<td>Winding rise \u2264 65 K (class A), oil rise \u2264 60 K (typical)<\/td>\n<\/tr>\n<tr>\n<td>Sound level test<\/td>\n<td>IEC 60076-10<\/td>\n<td>Per agreed value; often 55\u201370 dB(A) for distribution units<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The factory testing procedure serves as the main evidence for the buyer that the product meets its warranty requirements. A full test on 10MVA transformer usually requires about 2-5 days and usually is already included in the cost of the device; however, requesting a witnessed test (either by the buyer himself or a third party) will involve some logistics but will provide much more peace of mind. It is important to note that IEC 60076-1 allows for some positive loss tolerance, which means that the manufacturer can provide losses that are somewhat greater than the loss guarantee level. Thus, negotiating the loss guarantees and checking the numbers tested is a good commercial tool, not just a formality.<\/p>\n<h2 id=\"optimization\">Optimization Paths: Lean, Automation &amp; Digital QC<\/h2>\n<p>The contemporary manufacturing industry seeks to maintain a high level of quality while at the same time reducing costs, utilizing various tactics. One of them is the process of lean production, which adopts methods that enable companies to diminish material transportation, create uniform work processes and implement 5S technique exclusively throughout all its stations. Moreover, this methodology enables companies to minimize the number of manual errors. For instance, production process automation of such procedures as cutting, winding process control and brazing provides factories with an opportunity to eliminate the influence that manual labor has on the final productivity. For instance, machines that perform the winding process keep tension in wires constantly within \u00b13% tolerances as opposed to doing this manually.<\/p>\n<p>The third method is the use of digital quality records. Compared to using visual tests on paper, factories prefer to keep all the necessary information in databases, which allows identifying issues beforehand. Basically, this is the area Chinese companies focused on significantly during their production process. The latest machines can track the number of turns, torque, drying process and quality and ensure a quality check for every product from the very beginning. The practical suggestion for customers would be to ask for the digital traceability summary and quality check documents as it will tell them more about the factory than any promotion materials.<\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-10843\" src=\"https:\/\/subian-electric.com\/wp-content\/uploads\/2026\/08\/How-to-Audit-a-Transformer-Factory.webp\" alt=\"How to Audit a Transformer Factory\" width=\"1448\" height=\"1086\" \/><\/p>\n<h2 id=\"supplier\">How to Audit a Transformer Factory<\/h2>\n<p>If you&#8217;re purchasing several pieces of equipment you should know that factory audits are definitely worth much more than their cost. You should have a small checklist with you and search for actions rather than for papers. First, it is necessary to inspect the materials warehouse: whether steel is kept dry and sheltered, was oil kept either under nitrogen or in a tight container. Secondly, it is time to check the drying line: require for the real records of the drying cycle of the last piece of equipment and make sure vacuum and time periods are according to the specifications. Thirdly, you should check the quality control stations: do the records account the number of rotations and resistance on the computer or paper. Fourthly, you should check the testing floor: does the factory use the full IEC 60076-1 tests and could you watch the performance of the test? Fifthly, you need to check the handling of non-conformance units: what happens with a unit that has failed tests \u2014 is it rewired accordingly or sent away unnoticed?<\/p>\n<p>Also, you should get references for running installations and export history which will allow you to check customs and inspection records. A factory able to present the running unit in your region, test reports, and successful practices is definitely a reliable partner but if it doesn&#8217;t have such documents it is a big risk. Jiangsu Subian Electric Power, as the IEC 60076 compliant manufacturer exporting all over the world is open for the inspection and the companies which are open for the inspection usually pass it successfully.<\/p>\n<table>\n<thead>\n<tr>\n<th>Common Defect<\/th>\n<th>Root Cause<\/th>\n<th>Detection Point<\/th>\n<th>Prevention<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>High no-load loss<\/td>\n<td>Poor steel, burrs, crushed lamination insulation<\/td>\n<td>Core test, no-load loss test<\/td>\n<td>Steel loss sorting, burr &lt; 0.02 mm<\/td>\n<\/tr>\n<tr>\n<td>Winding resistance imbalance<\/td>\n<td>Bad transposition, joint issues<\/td>\n<td>Winding resistance test<\/td>\n<td>Controlled tension, verified transpositions<\/td>\n<\/tr>\n<tr>\n<td>Partial discharge at test<\/td>\n<td>Moisture, bubbles, insulation damage<\/td>\n<td>PD measurement<\/td>\n<td>End-point-controlled drying, vacuum filling<\/td>\n<\/tr>\n<tr>\n<td>Leaks in service<\/td>\n<td>Weld defects, gasket issues<\/td>\n<td>Pressure test, tank inspection<\/td>\n<td>Robotic welding, vision inspection<\/td>\n<\/tr>\n<tr>\n<td>OLTC failure early life<\/td>\n<td>Assembly contamination, torque errors<\/td>\n<td>OLTC timing\/contact tests<\/td>\n<td>Clean-room assembly, guided torque tools<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2 id=\"faq\">\u0627\u0644\u0623\u0633\u0626\u0644\u0629 \u0627\u0644\u0645\u062a\u0643\u0631\u0631\u0629<\/h2>\n<h3>What is the most important quality control step in transformer manufacturing?<\/h3>\n<p>The most skilled professionals are bound to name vacuum drying and oil saturation the reason for malfunctioning as moisture is responsible for a large part of failures that occur in operation. Moisture in paper must be decreased below 0.5% and oil must be processed by being degassed and treated by vacuum to form no bubbles. An organization that tries to speed up drying process saves hours on manufacturing but dooms the equipment to premature aging and potential partial discharge. The evidence is given by the index of polarization after filling. It is normal if the index exceeds 2.0, and it shows a problem if it goes below 1.5.<\/p>\n<h3>What factory tests should I insist on before accepting a transformer?<\/h3>\n<p>I would recommend requiring the factory to perform a complete set of tests which include IEC 60076-1 regulation tests such as tests of turn ratio, winding resistance, insulation resistance as well as tests of losses and impedances which involves tests of dielectric strength. When you deal with transformers that are large or sensitive to noise, you should also conduct the tests of the rise of temperature and the level of noise that is generated by the new machine. In case the transformer will be used in application with risk of short-circuit existence, you will need to require short-circuit tests as well. Make sure that you know about the testing process before making the decision regarding your large purchase.<\/p>\n<h3>How much does a factory test report cost?<\/h3>\n<p>Routine factory tests are regularly contained in the price of a transformer and take usually 2 to 5 days for the 10MVA transformer. Special tests such as rise checking will require extra cash that will be $2000-15000 depending on the complexity of a test. However, one should fully understand that the price of eliminating the errors that are found out after the process has already cost some money.<\/p>\n<h3>What tolerance can I expect on guaranteed losses?<\/h3>\n<p>According to IEC 60076-1 regulation, the difference in the losses can be +15% to the percentage that is established in the contract for the production. Therefore, the manufacturer is allowed to underperform by maximum 15% during manufacturing stages. For the qualified factories, however, the deviation means that the values should be set rather accurately and the tolerance will have to be the lowest possible due to the importance of losses.<\/p>\n<h3>How can I tell if a transformer manufacturer is truly IEC compliant?<\/h3>\n<p>Three regulations should be followed in order to be sure that you are dealing with an efficient manufacturer: check for the current ISO certification, require a statistics report of previous operations, and check the factory testing plan of the manufacturer in question which users will have to read.<\/p>\n<h2 id=\"references\">\u0627\u0644\u0645\u0631\u0627\u062c\u0639<\/h2>\n<ul>\n<li><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/639\" rel=\"nofollow noopener\" target=\"_blank\">IEC 60076-1: Power transformers \u2013 Part 1: General<\/a> \u2014 the backbone standard for rating, loss tolerance, and factory testing.<\/li>\n<li><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/639\" rel=\"nofollow noopener\" target=\"_blank\">IEC 60076-3: Power transformers \u2013 Part 3: Insulation levels and dielectric tests<\/a> \u2014 defines insulation coordination and dielectric test requirements.<\/li>\n<li><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/639\" rel=\"nofollow noopener\" target=\"_blank\">IEC 60076-5: Power transformers \u2013 Part 5: Ability to withstand short circuit<\/a> \u2014 the standard governing short-circuit withstand qualification.<\/li>\n<li><a href=\"https:\/\/standards.ieee.org\/ieee\/43\/10742\/\" rel=\"nofollow noopener\" target=\"_blank\">IEEE 43: Insulation Resistance and Polarization Index Testing<\/a> \u2014 referenced acceptance criteria for insulation dryness.<\/li>\n<li><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/639\" rel=\"nofollow noopener\" target=\"_blank\">IEC 60270: High-voltage test techniques \u2013 Partial discharge measurements<\/a> \u2014 the measurement standard behind PD acceptance criteria.<\/li>\n<li><a href=\"https:\/\/www.iso.org\/standard\/62085.html\" rel=\"nofollow noopener\" target=\"_blank\">ISO 9001: Quality management systems<\/a> \u2014 the system framework most transformer factories use for process control.<\/li>\n<li><a href=\"https:\/\/subian-electric.com\/ar\/\" rel=\"nofollow\">\u0634\u0631\u0643\u0629 \u062c\u064a\u0627\u0646\u063a\u0633\u0648 \u0633\u0648\u0628\u064a\u0646 \u0644\u0644\u0637\u0627\u0642\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629<\/a> \u2014 IEC 60076-compliant transformer manufacturer with witnessed testing and full factory test documentation.<\/li>\n<\/ul>\n<h2 id=\"conclusion\">\u0627\u0644\u062e\u0627\u062a\u0645\u0629<\/h2>\n<p>The manufacturing quality control process of power transformers consists of various measurable steps from incoming steel to the final acceptance test in the factory. There are five key quality checks involved along the process, namely: incoming inspection, manufacturing of core and windings, vacuum drying, assembling, and factory testing. Each of these checks has very specific criteria which make it easy for the customer to decide between a trusted company and a fraud. The optimization techniques which improve both quality and costs during the manufacturing process include lean methodology, automation, and digital tracking of the final product. This is something the customer should check during the factory audit.<\/p>\n<ul>\n<li>Always conduct verification of properties at receipt; this is the cheapest way to monitor quality.<\/li>\n<li>Make sure the factory can achieve insulation in the oven equal to at least 2.0 and moisture less than 0.5%.<\/li>\n<li>Make sure the factory did all routine tests according to the IEC 60076-1 standard, especially for big orders.<\/li>\n<li>Negotiate the acceptable losses values and check the actual data against guarantee figures.<\/li>\n<li>Auditing of drying records of products and their traceability is also very important.<\/li>\n<li>Your purchase list should definitely include Jiangsu Subian Electric Power if you want to do manufacturing in accordance with IEC standards and have all the certificates of tests.<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>A transformer with winding resistance within 0.5% between the three phases, whose paper insulation has been dried in accordance with the requirements (0.5% moisture or less) and has undergone no-load loss tests that confirm the guaranteed levels within 3%, would survive and function for many years.On the contrary, a transformer that is constructed by careless [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":10841,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[77],"tags":[],"class_list":["post-10840","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/subian-electric.com\/ar\/wp-json\/wp\/v2\/posts\/10840","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/subian-electric.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/subian-electric.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/subian-electric.com\/ar\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/subian-electric.com\/ar\/wp-json\/wp\/v2\/comments?post=10840"}],"version-history":[{"count":2,"href":"https:\/\/subian-electric.com\/ar\/wp-json\/wp\/v2\/posts\/10840\/revisions"}],"predecessor-version":[{"id":11002,"href":"https:\/\/subian-electric.com\/ar\/wp-json\/wp\/v2\/posts\/10840\/revisions\/11002"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/subian-electric.com\/ar\/wp-json\/wp\/v2\/media\/10841"}],"wp:attachment":[{"href":"https:\/\/subian-electric.com\/ar\/wp-json\/wp\/v2\/media?parent=10840"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/subian-electric.com\/ar\/wp-json\/wp\/v2\/categories?post=10840"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/subian-electric.com\/ar\/wp-json\/wp\/v2\/tags?post=10840"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}