Demander un devis
COMPANY PROFILE

Single Phase To 3 Phase Transformer Manufacturers – Phase Conversion Experts

Subian Electric manufactures phase conversion transformers that allow three-phase equipment – motors, compressors and machinery – to run from a single-phase supply. Our 50,000-square-metre factory in Xuzhou, Jiangsu, China, has supplied power equipment to 50+ countries since 2019.
As a factory-direct manufacturer and supplier, we build single-phase input, three-phase output units from 5 kVA to 500 kVA, engineered to your motor starting method and duty cycle, with complete test documentation.
Tell us your single-phase supply, motor rating and starting method. Our export team will confirm the design, price and lead time.

Subian Electric ISO9001 CE and UL product certification marks
Single phase to three phase transformer vacuum drying at Subian
Factory-Direct Manufacturer
Since 2019 · 50,000m² · 350+ Staff
50,000m²Base de fabrication
1→3Phase Conversion
350+Employés
50+Countries Served
OEM/ODMSupport
WholesaleSupply

Single-Phase Input Transformers We Manufacture

Custom 1-to-3 phase conversion transformers on oil-immersed and dry-type platforms, sized for motor starting and continuous three-phase loads in agriculture, workshops and small industry.

What Is a Single Phase To 3 Phase Transformer? Types & Buyer Guide

A single phase to three phase transformer – also called a phase conversion transformer – derives a three-phase output from a single-phase supply using passive windings and phase-shifting capacitors or inductors. It lets standard three-phase motors and equipment run where only single-phase power is available.

The most common use is driving three-phase irrigation pumps, workshop machinery and air compressors from a single-phase rural or commercial supply. A properly designed unit starts the motor reliably and balances the phases under load.

  • Motor-start capable – designs sized for locked-rotor current and starting method.
  • 5 kVA – 500 kVA – custom capacity range for agriculture and light industry.
  • Passive and robust – no power electronics – reliable in remote locations.
  • 50,000m² factory – winding, drying, assembly and testing under one roof.
  • 350+ employees – engineering support for motor and load matching.
  • OEM / ODM & wholesale – private labelling, packaging and volume pricing.

Main Types of Single Phase To Three Phase Transformers

Three build options cover most single-phase input projects:

Capacitor-assisted static type

Phase-shifting capacitors create the missing phases – simple and economical for fixed motor loads.

Winding-connected type

Dedicated conversion winding with balanced three-phase output for continuous and mixed loads.

Dry-type indoor unit

Fire-safe, low-maintenance build for workshops, pump rooms and commercial facilities.

Single Phase To Three Phase Transformer Specifications

Paramètre Specification
Input Single-phase 0.22 kV – 0.4 kV
Output Three-phase 0.4 kV / 0.48 kV
Capacité nominale 5 kVA – 500 kVA
Fréquence 50/60 Hz
Motor starting Direct-on-line / star-delta compatible
Norme IEC 60076 / GB 1094

Phase Conversion Manufacturing at Our 50,000 m² Factory

Each unit passes controlled material preparation, winding, vacuum drying, assembly, inspection and packing at our Xuzhou facility, with the conversion performance verified in the factory test room.

Single Phase To 3 Phase Transformer Factory Price – Request a Quote

Send your specification, voltage level, capacity and quantity. Our export team will respond with factory pricing, lead time and drawings for approval.

OEM/ODM & Wholesale Single Phase To Three Phase Transformer Supply

Rebrand or resell phase conversion transformers with full factory backing – custom nameplates, packaging and documentation included.

OEM ODM manufacturing service

OEM / ODM

Factory-Direct

Custom branding, packaging and product variants built on our standard platforms – from a nameplate to full product design.


Custom nameplate · Custom packaging · Full test docs

Wholesale supply with factory pricing

Wholesale Supply

Volume Pricing

Factory pricing with flexible container quantities, mixed models per container and reliable global shipping for volume buyers and importers.


Container MOQ · Mixed models · Global shipping

Distributor support with account management

Distributor Support

Channel Partners

Dedicated account management, technical documentation and priority production for distributors and project clients.


Account manager · Sales material · Priority lead times

Transformer-Based Phase Conversion vs Rotary and Static Converters

Rotary converters use a motor-generator set that is noisy, heavy and power-hungry. Static electronic converters are cheap but harmonic-rich and weak at motor starting. A transformer-based phase converter balances the two – robust, clean output and strong starting torque.

For irrigation and workshop duty where the motor must start every day and run unattended, the transformer-based solution delivers the best balance of reliability, maintenance and total cost.

Comparison and selection guide
Manufacturers and suppliers in China

Choosing a Single Phase To 3 Phase Transformer Manufacturer

The critical question is whether the manufacturer can size the unit for your motor’s starting current – most catalogue units cannot start a three-phase motor reliably. Look for engineering support and test evidence, not just a price list.

Subian Electric brings a 50,000m² factory, 350+ employees, ISO9001, CE and UL certification and export to 50+ countries, with in-house winding design for phase conversion projects.

Send your motor rating, starting method and duty cycle – our engineers will confirm the unit design and price before production.

Certifications & Quality Assurance

Our phase conversion transformers are produced under ISO9001, ISO14001 and ISO45001 management systems, with CE and UL certification and factory testing on every unit.

Product Certifications

FAQs

Single Phase To 3 Phase Transformer FAQ: Motor & Sourcing Questions

Answers to the questions buyers ask most when running three-phase equipment from a single-phase supply.

Un approvisionnement monophasé peut-il faire fonctionner un moteur triphasé ?
Yes – with a phase conversion transformer that derives the missing phases. The unit must be sized for the motor’s starting current, which is why we ask for the motor rating and starting method.
How do I size the transformer for my motor?
The unit must handle the locked-rotor current of the largest motor plus the running load of everything connected. Provide motor kW, voltage and starting method, and we will confirm the kVA.
What is the difference between a static converter and this type of transformer?
Static converters synthesise phases electronically and can struggle with heavy starting loads. A phase conversion transformer uses windings and capacitors for robust, clean three-phase output.
Can the unit run more than one motor?
Yes – multiple motors can be connected if the total starting demand is accounted for. We design for the worst-case starting scenario of the largest motor.
Do you support OEM branding?
Yes – OEM and ODM supply includes custom nameplates, packaging and documentation for distributors and brands.
What is the lead time?
Confirmed with your order and project schedule, aligned with your site readiness and equipment mix.

Contact Subian

Need the Right Specification?

Tell us your target market, product type, quantity and technical requirements. Our team will help you identify a suitable configuration for your project.

Contact Form Demo
Your inquiry is sent directly to our export sales team.