{"id":11522,"date":"2026-09-11T12:21:38","date_gmt":"2026-09-11T04:21:38","guid":{"rendered":"https:\/\/subian-electric.com\/?page_id=11522"},"modified":"2026-09-11T12:21:38","modified_gmt":"2026-09-11T04:21:38","slug":"175-kva-transformer","status":"publish","type":"page","link":"https:\/\/subian-electric.com\/fr\/175-kva-transformer\/","title":{"rendered":"Transformateur de 175 kVA"},"content":{"rendered":"\n<section class=\"web-sem-module web-sem-module-one\" style=\"min-width: 100%;\">\n<div class=\"web-sem-container\">\n<div class=\"web-sem-flex-box\">\n<div class=\"web-sem-text\"><span class=\"web-sem-tag\">COMPANY PROFILE<\/span>\n<h1>175 kVA Transformer<\/h1>\n<p>Subian Electric manufactures 175 kVA distribution transformers for 11kV, 20kV and 33kV networks stepping down to 400V. The rating sits between the standard 160 kVA and 200 kVA steps, which makes it a project and replacement size: buyers specify it where an existing unit is being matched, where a load calculation lands between the catalogue steps, or where a network operator&#8217;s standard calls for it.<br \/>Our distribution transformer series covers 30-2,500 kVA in both oil-immersed and dry-type construction, so the 175 kVA rating is built on the same platform as the standard sizes &#8211; Yyn0, Dyn11 or Yzn11 connection, 4-6% impedance, ONAN cooling and IEC 60076 \/ GB 1094 testing, with a full-load current of about 253 A on a 400V secondary.<br \/>Send your primary voltage, secondary voltage and load details, and our engineers will confirm the 175 kVA rating, losses, dimensions and a written factory quotation.<\/p>\n<div style=\"margin-top: 24px;\"><img decoding=\"async\" style=\"max-width: 100%; height: auto; border-radius: 8px; box-shadow: 0 4px 20px rgba(0,0,0,0.08);\" src=\"\/wp-content\/uploads\/2026\/08\/subian-product-certification-marks.png\" alt=\"Subian Electric ISO9001 CE and UL certification marks for distribution transformers\" \/><\/div>\n<div class=\"hy-lb-btn-wrap\" style=\"margin-top: 20px;\"><a class=\"hy-lb-btn\" href=\"\/contact-us\/\">Get a Quote<\/a><\/div>\n<\/div>\n<div class=\"web-sem-media\">\n<div class=\"web-sem-main-img web-sem-rect-75\"><img decoding=\"async\" class=\"web-sem-full\" src=\"\/wp-content\/uploads\/2026\/08\/6-10KV-Oil-Immersed-Power-Distribution-Transformer-2-1.webp\" alt=\"175 kVA oil-immersed distribution transformer for 11kV to 400V supply\" \/><\/div>\n<div class=\"web-sem-float-card\"><strong>Factory-Direct Manufacturer<\/strong><br \/>Since 2019 \u00b7 50,000m\u00b2 \u00b7 350+ Staff<\/div>\n<\/div>\n<\/div>\n<div class=\"web-sem-stats-grid\">\n<div class=\"web-sem-stat-item\"><strong>50,000m\u00b2<\/strong>Manufacturing Base<\/div>\n<div class=\"web-sem-stat-item\"><strong>Up to 110kV<\/strong>Type-Tested Capability<\/div>\n<div class=\"web-sem-stat-item\"><strong>350+<\/strong>Employees<\/div>\n<div class=\"web-sem-stat-item\"><strong>50+<\/strong>Countries Served<\/div>\n<div class=\"web-sem-stat-item\"><strong>OEM\/ODM<\/strong>Support<\/div>\n<div class=\"web-sem-stat-item\"><strong>Wholesale<\/strong>Supply<\/div>\n<\/div>\n<\/div>\n<\/section>\n\n<section class=\"singlepage-products-section\" style=\"min-width: 100%;\">\n<div class=\"singlepage-container\">\n<h2 class=\"singlepage-section-title\">Distribution Transformers We Build<\/h2>\n<p class=\"singlepage-section-desc\">Oil-immersed and dry-type distribution transformers from 30 kVA to 2,500 kVA, including 175 kVA units for 11kV, 20kV and 33kV networks.<\/p>\n<div class=\"woocommerce columns-4 \"><ul class=\"products columns-4\" data-products=\"type-3\" data-hover=\"zoom-in\">\n<li class=\"product type-product post-2007 status-publish first instock product_cat-dry-type-transformer product_cat-all-product product_cat-transformer product_tag-amorphous-alloy-transformer product_tag-dry-type-transformer product_tag-scbh-series has-post-thumbnail shipping-taxable product-type-simple\">\n\t<a href=\"https:\/\/subian-electric.com\/fr\/product\/10kv-dry-type-transformer-scbh-series\/\" class=\"woocommerce-LoopProduct-link woocommerce-loop-product__link\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/subian-electric.com\/wp-content\/uploads\/2026\/08\/f3d771df622f51ee2386b290a0e687e.png\" class=\"attachment-woocommerce_thumbnail size-woocommerce_thumbnail\" alt=\"10kV  Dry-Type Transformer-SCBH series Amorphous Alloy\" \/><h2 class=\"woocommerce-loop-product__title\">10kV  Dry-Type Transformer-SCBH series Amorphous Alloy<\/h2>\n<\/a><a href=\"https:\/\/subian-electric.com\/fr\/product\/10kv-dry-type-transformer-scbh-series\/\" aria-describedby=\"woocommerce_loop_add_to_cart_link_describedby_2007\" data-quantity=\"1\" class=\"button product_type_simple\" data-product_id=\"2007\" data-product_sku=\"\" aria-label=\"En savoir plus sur &ldquo;10kV  Dry-Type Transformer-SCBH series Amorphous Alloy&rdquo;\" rel=\"nofollow\" data-success_message=\"\">Lire la suite<\/a>\t<span id=\"woocommerce_loop_add_to_cart_link_describedby_2007\" class=\"screen-reader-text\">\n\t\t\t<\/span>\n<\/li>\n<li class=\"product type-product post-1966 status-publish instock product_cat-dry-type-transformer product_cat-all-product product_cat-transformer product_tag-20-35kv-transformer product_tag-cast-resin-transformer product_tag-dry-type-transformer has-post-thumbnail shipping-taxable product-type-simple\">\n\t<a href=\"https:\/\/subian-electric.com\/fr\/product\/20-35kv-dry-type-transformer\/\" class=\"woocommerce-LoopProduct-link woocommerce-loop-product__link\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/subian-electric.com\/wp-content\/uploads\/2026\/08\/1-1.jpg\" class=\"attachment-woocommerce_thumbnail size-woocommerce_thumbnail\" alt=\"20-35KV  Dry-Type Transformer\" \/><h2 class=\"woocommerce-loop-product__title\">20-35KV  Dry-Type Transformer<\/h2>\n<\/a><a href=\"https:\/\/subian-electric.com\/fr\/product\/20-35kv-dry-type-transformer\/\" aria-describedby=\"woocommerce_loop_add_to_cart_link_describedby_1966\" data-quantity=\"1\" class=\"button product_type_simple\" data-product_id=\"1966\" data-product_sku=\"\" aria-label=\"En savoir plus sur &ldquo;20-35KV  Dry-Type Transformer&rdquo;\" rel=\"nofollow\" data-success_message=\"\">Lire la suite<\/a>\t<span id=\"woocommerce_loop_add_to_cart_link_describedby_1966\" class=\"screen-reader-text\">\n\t\t\t<\/span>\n<\/li>\n<li class=\"product type-product post-1999 status-publish instock product_cat-dry-type-transformer product_cat-all-product product_cat-transformer product_tag-cast-resin-transformer product_tag-dry-type-transformer product_tag-scb-series has-post-thumbnail shipping-taxable product-type-simple\">\n\t<a href=\"https:\/\/subian-electric.com\/fr\/product\/20-35kv-scb-series-epoxy-resin-dry-type-transformer\/\" class=\"woocommerce-LoopProduct-link woocommerce-loop-product__link\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/subian-electric.com\/wp-content\/uploads\/2026\/08\/1-1.jpg\" class=\"attachment-woocommerce_thumbnail size-woocommerce_thumbnail\" alt=\"20-35KV SCB Series Epoxy Resin Dry-Type Transformer\" \/><h2 class=\"woocommerce-loop-product__title\">20-35KV SCB Series Epoxy Resin Dry-Type Transformer<\/h2>\n<\/a><a href=\"https:\/\/subian-electric.com\/fr\/product\/20-35kv-scb-series-epoxy-resin-dry-type-transformer\/\" aria-describedby=\"woocommerce_loop_add_to_cart_link_describedby_1999\" data-quantity=\"1\" class=\"button product_type_simple\" data-product_id=\"1999\" data-product_sku=\"\" aria-label=\"En savoir plus sur &ldquo;20-35KV SCB Series Epoxy Resin Dry-Type Transformer&rdquo;\" rel=\"nofollow\" data-success_message=\"\">Lire la suite<\/a>\t<span id=\"woocommerce_loop_add_to_cart_link_describedby_1999\" class=\"screen-reader-text\">\n\t\t\t<\/span>\n<\/li>\n<li class=\"product type-product post-2005 status-publish last instock product_cat-oil-immersed-transformer product_cat-all-product product_cat-transformer product_tag-20kv-transformer product_tag-distribution-transformer product_tag-oil-immersed-distribution-transformer has-post-thumbnail shipping-taxable product-type-simple\">\n\t<a href=\"https:\/\/subian-electric.com\/fr\/product\/20kv-oil-immersed-distribution-transformer\/\" class=\"woocommerce-LoopProduct-link woocommerce-loop-product__link\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/subian-electric.com\/wp-content\/uploads\/2026\/08\/20kv-high-voltage-oil-immersed-distribution-transformer-3.jpg\" class=\"attachment-woocommerce_thumbnail size-woocommerce_thumbnail\" alt=\"20KV Oil-immersed Distribution Transformer\" \/><h2 class=\"woocommerce-loop-product__title\">20KV Oil-immersed Distribution Transformer<\/h2>\n<\/a><a href=\"https:\/\/subian-electric.com\/fr\/product\/20kv-oil-immersed-distribution-transformer\/\" aria-describedby=\"woocommerce_loop_add_to_cart_link_describedby_2005\" data-quantity=\"1\" class=\"button product_type_simple\" data-product_id=\"2005\" data-product_sku=\"\" aria-label=\"En savoir plus sur &ldquo;20KV Oil-immersed Distribution Transformer&rdquo;\" rel=\"nofollow\" data-success_message=\"\">Lire la suite<\/a>\t<span id=\"woocommerce_loop_add_to_cart_link_describedby_2005\" class=\"screen-reader-text\">\n\t\t\t<\/span>\n<\/li>\n<li class=\"product type-product post-2001 status-publish first instock product_cat-oil-immersed-transformer product_cat-all-product product_cat-transformer product_tag-35kv-transformer product_tag-oil-immersed-power-transformer product_tag-power-transformer has-post-thumbnail shipping-taxable product-type-simple\">\n\t<a href=\"https:\/\/subian-electric.com\/fr\/product\/35kv-oil-immersed-power-transformer\/\" class=\"woocommerce-LoopProduct-link woocommerce-loop-product__link\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/subian-electric.com\/wp-content\/uploads\/2026\/08\/35kvoil-immersed-power-transformer-1.jpg\" class=\"attachment-woocommerce_thumbnail size-woocommerce_thumbnail\" alt=\"35KV Oil-immersed Power Transformer\" \/><h2 class=\"woocommerce-loop-product__title\">35KV Oil-immersed Power Transformer<\/h2>\n<\/a><a href=\"https:\/\/subian-electric.com\/fr\/product\/35kv-oil-immersed-power-transformer\/\" aria-describedby=\"woocommerce_loop_add_to_cart_link_describedby_2001\" data-quantity=\"1\" class=\"button product_type_simple\" data-product_id=\"2001\" data-product_sku=\"\" aria-label=\"En savoir plus sur &ldquo;35KV Oil-immersed Power Transformer&rdquo;\" rel=\"nofollow\" data-success_message=\"\">Lire la suite<\/a>\t<span id=\"woocommerce_loop_add_to_cart_link_describedby_2001\" class=\"screen-reader-text\">\n\t\t\t<\/span>\n<\/li>\n<li class=\"product type-product post-1998 status-publish instock product_cat-oil-immersed-transformer product_cat-all-product product_cat-transformer product_tag-6-10kv-transformer product_tag-distribution-transformer product_tag-oil-immersed-distribution-transformer has-post-thumbnail shipping-taxable product-type-simple\">\n\t<a href=\"https:\/\/subian-electric.com\/fr\/product\/6-10kv-oil-immersed-power-distribution-transformer\/\" class=\"woocommerce-LoopProduct-link woocommerce-loop-product__link\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/subian-electric.com\/wp-content\/uploads\/2026\/08\/kp0a4190.png\" class=\"attachment-woocommerce_thumbnail size-woocommerce_thumbnail\" alt=\"6-10KV Oil-Immersed Power Distribution Transformer\" \/><h2 class=\"woocommerce-loop-product__title\">6-10KV Oil-Immersed Power Distribution Transformer<\/h2>\n<\/a><a href=\"https:\/\/subian-electric.com\/fr\/product\/6-10kv-oil-immersed-power-distribution-transformer\/\" aria-describedby=\"woocommerce_loop_add_to_cart_link_describedby_1998\" data-quantity=\"1\" class=\"button product_type_simple\" data-product_id=\"1998\" data-product_sku=\"\" aria-label=\"En savoir plus sur &ldquo;6-10KV Oil-Immersed Power Distribution Transformer&rdquo;\" rel=\"nofollow\" data-success_message=\"\">Lire la suite<\/a>\t<span id=\"woocommerce_loop_add_to_cart_link_describedby_1998\" class=\"screen-reader-text\">\n\t\t\t<\/span>\n<\/li>\n<li class=\"product type-product post-1932 status-publish instock product_cat-new-energy-box-change product_cat-all-product product_tag-current-transformer product_tag-epoxy-resin-ct product_tag-indoor-current-transformer has-post-thumbnail shipping-taxable product-type-simple\">\n\t<a href=\"https:\/\/subian-electric.com\/fr\/product\/current-transformer-10kv-indoor-high-voltage\/\" class=\"woocommerce-LoopProduct-link woocommerce-loop-product__link\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/subian-electric.com\/wp-content\/uploads\/2026\/08\/h4f0a38a16f8d431cabf296113e8a958291-300x300-1.jpg\" class=\"attachment-woocommerce_thumbnail size-woocommerce_thumbnail\" alt=\"Current Transformer --10KV Indoor High Voltage\" \/><h2 class=\"woocommerce-loop-product__title\">Current Transformer &#8211;10KV Indoor High Voltage<\/h2>\n<\/a><a href=\"https:\/\/subian-electric.com\/fr\/product\/current-transformer-10kv-indoor-high-voltage\/\" aria-describedby=\"woocommerce_loop_add_to_cart_link_describedby_1932\" data-quantity=\"1\" class=\"button product_type_simple\" data-product_id=\"1932\" data-product_sku=\"\" aria-label=\"En savoir plus sur &ldquo;Current Transformer --10KV Indoor High Voltage&rdquo;\" rel=\"nofollow\" data-success_message=\"\">Lire la suite<\/a>\t<span id=\"woocommerce_loop_add_to_cart_link_describedby_1932\" class=\"screen-reader-text\">\n\t\t\t<\/span>\n<\/li>\n<li class=\"product type-product post-1926 status-publish last instock product_cat-new-energy-box-change product_cat-all-product product_tag-current-transformer product_tag-instrument-transformer product_tag-wound-current-transformer has-post-thumbnail shipping-taxable product-type-simple\">\n\t<a href=\"https:\/\/subian-electric.com\/fr\/product\/current-transformer-lmzk-wound-current-transformer300-5a\/\" class=\"woocommerce-LoopProduct-link woocommerce-loop-product__link\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/subian-electric.com\/wp-content\/uploads\/2026\/08\/h94b3287a0c02400cb3896e070dd056b3o-300x300.webp\" class=\"attachment-woocommerce_thumbnail size-woocommerce_thumbnail\" alt=\"Current Transformer--LMZK Wound Current Transformer300\/5a\" \/><h2 class=\"woocommerce-loop-product__title\">Current Transformer&#8211;LMZK Wound Current Transformer300\/5a<\/h2>\n<\/a><a href=\"https:\/\/subian-electric.com\/fr\/product\/current-transformer-lmzk-wound-current-transformer300-5a\/\" aria-describedby=\"woocommerce_loop_add_to_cart_link_describedby_1926\" data-quantity=\"1\" class=\"button product_type_simple\" data-product_id=\"1926\" data-product_sku=\"\" aria-label=\"En savoir plus sur &ldquo;Current Transformer--LMZK Wound Current Transformer300\/5a&rdquo;\" rel=\"nofollow\" data-success_message=\"\">Lire la suite<\/a>\t<span id=\"woocommerce_loop_add_to_cart_link_describedby_1926\" class=\"screen-reader-text\">\n\t\t\t<\/span>\n<\/li>\n<li class=\"product type-product post-1928 status-publish first instock product_cat-new-energy-box-change product_cat-oil-immersed-transformer product_cat-all-product product_cat-transformer product_tag-bar-type-ct product_tag-current-transformer product_tag-three-phase-current-transformer has-post-thumbnail shipping-taxable product-type-simple\">\n\t<a href=\"https:\/\/subian-electric.com\/fr\/product\/current-transformer-lsy-10-transformer-integrated-ct\/\" class=\"woocommerce-LoopProduct-link woocommerce-loop-product__link\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/subian-electric.com\/wp-content\/uploads\/2026\/08\/h2f56a44db3a6408d8a0975c84031b3bck11-300x300-1.png\" class=\"attachment-woocommerce_thumbnail size-woocommerce_thumbnail\" alt=\"Current Transformer--LSY-10 transformer Integrated CT\" \/><h2 class=\"woocommerce-loop-product__title\">Current Transformer&#8211;LSY-10 transformer Integrated CT<\/h2>\n<\/a><a href=\"https:\/\/subian-electric.com\/fr\/product\/current-transformer-lsy-10-transformer-integrated-ct\/\" aria-describedby=\"woocommerce_loop_add_to_cart_link_describedby_1928\" data-quantity=\"1\" class=\"button product_type_simple\" data-product_id=\"1928\" data-product_sku=\"\" aria-label=\"En savoir plus sur &ldquo;Current Transformer--LSY-10 transformer Integrated CT&rdquo;\" rel=\"nofollow\" data-success_message=\"\">Lire la suite<\/a>\t<span id=\"woocommerce_loop_add_to_cart_link_describedby_1928\" class=\"screen-reader-text\">\n\t\t\t<\/span>\n<\/li>\n<li class=\"product type-product post-1930 status-publish instock product_cat-new-energy-box-change product_cat-all-product product_tag-current-transformer product_tag-ground-fault-protection product_tag-zero-sequence-current-transformer has-post-thumbnail shipping-taxable product-type-simple\">\n\t<a href=\"https:\/\/subian-electric.com\/fr\/product\/current-transformer-lxk-high-voltage-zero-sequence\/\" class=\"woocommerce-LoopProduct-link woocommerce-loop-product__link\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/subian-electric.com\/wp-content\/uploads\/2026\/08\/h5dcc01e22724407bbb4d1219883fc468a1-300x300-1.png\" class=\"attachment-woocommerce_thumbnail size-woocommerce_thumbnail\" alt=\"current transformer--LXK high voltage zero sequence\" \/><h2 class=\"woocommerce-loop-product__title\">current transformer&#8211;LXK high voltage zero sequence<\/h2>\n<\/a><a href=\"https:\/\/subian-electric.com\/fr\/product\/current-transformer-lxk-high-voltage-zero-sequence\/\" aria-describedby=\"woocommerce_loop_add_to_cart_link_describedby_1930\" data-quantity=\"1\" class=\"button product_type_simple\" data-product_id=\"1930\" data-product_sku=\"\" aria-label=\"En savoir plus sur &ldquo;current transformer--LXK high voltage zero sequence&rdquo;\" rel=\"nofollow\" data-success_message=\"\">Lire la suite<\/a>\t<span id=\"woocommerce_loop_add_to_cart_link_describedby_1930\" class=\"screen-reader-text\">\n\t\t\t<\/span>\n<\/li>\n<li class=\"product type-product post-2003 status-publish instock product_cat-dry-type-transformer product_cat-all-product product_cat-transformer product_tag-cast-resin-transformer product_tag-dry-type-transformer product_tag-scb-series has-post-thumbnail shipping-taxable product-type-simple\">\n\t<a href=\"https:\/\/subian-electric.com\/fr\/product\/dry-type-distribution-transformer-6-10-kv-scb-series\/\" class=\"woocommerce-LoopProduct-link woocommerce-loop-product__link\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/subian-electric.com\/wp-content\/uploads\/2026\/08\/dry-type-distribution-transformer-6-10-KV-SCB-series-epoxy-resin-cast-1-1-2.webp\" class=\"attachment-woocommerce_thumbnail size-woocommerce_thumbnail\" alt=\"dry type distribution transformer-6-10 KV SCB series epoxy resin cast\" \/><h2 class=\"woocommerce-loop-product__title\">dry type distribution transformer-6-10 KV SCB series epoxy resin cast<\/h2>\n<\/a><a href=\"https:\/\/subian-electric.com\/fr\/product\/dry-type-distribution-transformer-6-10-kv-scb-series\/\" aria-describedby=\"woocommerce_loop_add_to_cart_link_describedby_2003\" data-quantity=\"1\" class=\"button product_type_simple\" data-product_id=\"2003\" data-product_sku=\"\" aria-label=\"En savoir plus sur &ldquo;dry type distribution transformer-6-10 KV SCB series epoxy resin cast&rdquo;\" rel=\"nofollow\" data-success_message=\"\">Lire la suite<\/a>\t<span id=\"woocommerce_loop_add_to_cart_link_describedby_2003\" class=\"screen-reader-text\">\n\t\t\t<\/span>\n<\/li>\n<li class=\"product type-product post-1934 status-publish last instock product_cat-new-energy-box-change product_cat-all-product product_tag-instrument-transformer product_tag-potential-transformer product_tag-voltage-transformer has-post-thumbnail shipping-taxable product-type-simple\">\n\t<a href=\"https:\/\/subian-electric.com\/fr\/product\/electrical-transformers-jdz-10-power-voltage\/\" class=\"woocommerce-LoopProduct-link woocommerce-loop-product__link\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/subian-electric.com\/wp-content\/uploads\/2026\/08\/h62d1d2268850460b947a0f5239537f12m.webp\" class=\"attachment-woocommerce_thumbnail size-woocommerce_thumbnail\" alt=\"Electrical Transformers--JDZ - 10  Power Voltage\" \/><h2 class=\"woocommerce-loop-product__title\">Electrical Transformers&#8211;JDZ &#8211; 10  Power Voltage<\/h2>\n<\/a><a href=\"https:\/\/subian-electric.com\/fr\/product\/electrical-transformers-jdz-10-power-voltage\/\" aria-describedby=\"woocommerce_loop_add_to_cart_link_describedby_1934\" data-quantity=\"1\" class=\"button product_type_simple\" data-product_id=\"1934\" data-product_sku=\"\" aria-label=\"En savoir plus sur &ldquo;Electrical Transformers--JDZ - 10  Power Voltage&rdquo;\" rel=\"nofollow\" data-success_message=\"\">Lire la suite<\/a>\t<span id=\"woocommerce_loop_add_to_cart_link_describedby_1934\" class=\"screen-reader-text\">\n\t\t\t<\/span>\n<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/section>\n\n<section class=\"subian-semv2-acbr\" aria-labelledby=\"subian-semv2-acbr-title\">\n<div class=\"subian-semv2-acbr-split\">\n<div class=\"subian-semv2-acbr-text\">\n<h2 id=\"subian-semv2-acbr-title\">What Is a 175 kVA Transformer?<\/h2>\n<p class=\"subian-semv2-acbr-intro\">A 175 kVA transformer is a three-phase distribution transformer rated for 175 kilovolt-amperes of apparent power. It is normally a medium-voltage to low-voltage step-down unit &#8211; most often 11kV\/0.4kV, 20kV\/0.4kV or 33kV\/0.4kV &#8211; installed on a pole, a plinth or a compact substation to supply a small industrial site, a commercial building, a water pump or a residential distribution area.<\/p>\n<p>175 kVA is not one of the preferred IEC numbers (the standard steps run 100, 125, 160, 200 and 250 kVA), so it is usually a project rating rather than a stock catalogue size. That matters when you are replacing a unit: matching the existing rating, impedance and connection group is normally simpler than forcing the installation to a standard size, and a factory that builds the full 30-2,500 kVA range can supply it on the same platform as the standard steps.<\/p>\n<\/div>\n<ul class=\"subian-semv2-acbr-points\">\n<li><strong>175 kVA \/ 140 kW<\/strong> &#8211; apparent power at 0.8 power factor, three-phase.<\/li><li><strong>11 \/ 20 \/ 33 kV primary<\/strong> &#8211; stepping down to 400V, 415V or 0.69 kV.<\/li><li><strong>253 A at 400V<\/strong> &#8211; full-load secondary current for cable selection.<\/li><li><strong>4-6% impedance<\/strong> &#8211; matched to the upstream protection scheme.<\/li><li><strong>Oil-immersed or dry-type<\/strong> &#8211; outdoor pole\/plinth or indoor installation.<\/li><li><strong>IEC 60076 \/ GB 1094<\/strong> &#8211; routine test report with every unit.<\/li>\n<\/ul>\n<\/div>\n<h3 class=\"subian-semv2-acbr-subtitle\">175 kVA Configurations<\/h3><p class=\"subian-semv2-acbr-subtitle-desc\">The installation site decides the construction and the connection:<\/p><div class=\"subian-t2-types\"><div class=\"subian-t2-type\"><h4>Oil-immersed distribution type<\/h4><p>the economical standard for pole, plinth and outdoor use.<\/p><\/div><div class=\"subian-t2-type\"><h4>Dry-type \/ cast resin<\/h4><p>for indoor rooms where oil is not permitted.<\/p><\/div><div class=\"subian-t2-type\"><h4>Isolation and autotransformer variants<\/h4><p>for galvanic separation or voltage matching duty.<\/p><\/div><\/div>\n<h3 class=\"subian-semv2-acbr-subtitle\">175 kVA Transformer Specification (Typical)<\/h3><div class=\"subian-semv2-acbr-table-wrap\"><table class=\"subian-semv2-acbr-specs\"><thead><tr><th scope=\"col\">Parameter<\/th><th scope=\"col\">Specification<\/th><\/tr><\/thead><tbody><tr><th scope=\"row\">Rated capacity<\/th><td>175 kVA, three-phase (project rating between 160 and 200 kVA)<\/td><\/tr><tr><th scope=\"row\">Primary voltage<\/th><td>11 \/ 10.5 \/ 20 \/ 33 kV (factory series 6-33 kV)<\/td><\/tr><tr><th scope=\"row\">Secondary voltage<\/th><td>0.4 \/ 0.415 \/ 0.69 kV<\/td><\/tr><tr><th scope=\"row\">Full-load current<\/th><td>approx. 253 A at 400V; approx. 9.2 A at 11 kV<\/td><\/tr><tr><th scope=\"row\">No-load loss (typical)<\/th><td>0.29-0.35 kW depending on loss level<\/td><\/tr><tr><th scope=\"row\">Load loss at 75\u00b0C (typical)<\/th><td>2.2-2.6 kW<\/td><\/tr><tr><th scope=\"row\">Short-circuit impedance<\/th><td>4% typical (4-6% by rating)<\/td><\/tr><tr><th scope=\"row\">Connection group<\/th><td>Yyn0 \/ Dyn11 \/ Yzn11<\/td><\/tr><tr><th scope=\"row\">Cooling<\/th><td>ONAN (oil-immersed) \u00b7 AN\/AF (dry-type)<\/td><\/tr><tr><th scope=\"row\">Insulation class<\/th><td>F \/ H (dry-type)<\/td><\/tr><tr><th scope=\"row\">Standard<\/th><td>IEC 60076 \/ GB 1094 (dry-type: GB 10228)<\/td><\/tr><tr><th scope=\"row\">Factory series range<\/th><td>30-2,500 kVA, oil-immersed and dry-type<\/td><\/tr><\/tbody><\/table><\/div>\n<\/section>\n\n<section class=\"subian-semv2-acbr\" aria-labelledby=\"subian-semv2-acbr-title\"><h2 id=\"subian-semv2-acbr-title\" style=\"font-size:26px;line-height:1.35;\">175 kVA Transformer Amps and Current Rating<\/h2><p>175 kVA transformer amps depend on the voltage at each winding. On a 400V secondary the full-load current is about 253 A per phase; at 415V it is about 244 A; at 480V about 211 A; and on a 240V single-phase-derived system it rises to about 421 A. On the primary side the current is much smaller: about 9.2 A at 11 kV, 5.1 A at 20 kV and 3.1 A at 33 kV.<\/p><p>The secondary current is what sizes the cables or busbar and the outgoing protection, so it is worth stating the exact secondary voltage when ordering &#8211; a 400V and a 415V winding give different current ratings for the same kVA. For planning, the shortcut is that three-phase current equals kVA \u00d7 1,000 divided by (1.732 \u00d7 voltage); for a 175 kVA unit that is about 1.44 A per kVA at 400V.<\/p><h3 class=\"subian-semv2-acbr-subtitle\">175 kVA full-load current by voltage<\/h3><div class=\"subian-semv2-acbr-table-wrap\"><table class=\"subian-semv2-acbr-specs\"><tbody><tr><th scope=\"row\">400 V secondary<\/th><td>approx. 253 A<\/td><\/tr><tr><th scope=\"row\">415 V secondary<\/th><td>approx. 244 A<\/td><\/tr><tr><th scope=\"row\">480 V secondary<\/th><td>approx. 211 A<\/td><\/tr><tr><th scope=\"row\">240 V secondary<\/th><td>approx. 421 A<\/td><\/tr><tr><th scope=\"row\">11 kV primary<\/th><td>approx. 9.2 A<\/td><\/tr><tr><th scope=\"row\">20 kV primary<\/th><td>approx. 5.1 A<\/td><\/tr><tr><th scope=\"row\">33 kV primary<\/th><td>approx. 3.1 A<\/td><\/tr><\/tbody><\/table><\/div><\/section>\n<section class=\"subian-semv2-acbr\" aria-labelledby=\"subian-semv2-acbr-title\"><h2 id=\"subian-semv2-acbr-title\" style=\"font-size:26px;line-height:1.35;\">175 kVA Transformer Size, Dimensions and Weight<\/h2><p>Searches for size 175 kVA transformer, dimensions 175 kVA transformer or 175 kVA transformer weight all come down to the same four numbers: length, width, height and weight. A 175 kVA transformer size depends on construction and voltage class, but oil-immersed units in this range are compact enough for pole or plinth mounting. The questions we are asked most about this rating are the 175 kVA transformer amps, the 175 kVA transformer weight and the 175 kVA transformer dimensions, so all three are covered here with figures you can use for planning. As a reference point from our own production, a 100 kVA oil-immersed unit measures about 1,000-1,200 mm long, 500-700 mm deep and 1,100-1,400 mm high and weighs 600-900 kg; a 175 kVA unit scales to roughly 1,300-1,600 mm long, 700-900 mm wide and 1,300-1,700 mm high, with a weight of about 1,000-1,200 kg.<\/p><p>175 kVA transformer weight is dominated by the core, windings and oil: the oil charge for this rating is typically 150-200 litres, and the transport weight includes the tank, radiators and fittings. Dry-type units are heavier in the active part but lighter overall because there is no oil or tank &#8211; and they need clearances for air circulation instead of a bunded oil containment area. Confirm the final dimensions and weight on the approval drawing before arranging lifting or pole hardware.<\/p><h3 class=\"subian-semv2-acbr-subtitle\">Indicative 175 kVA dimensions and weight (confirm on drawings)<\/h3><div class=\"subian-semv2-acbr-table-wrap\"><table class=\"subian-semv2-acbr-specs\"><tbody><tr><th scope=\"row\">Oil-immersed, dimensions<\/th><td>approx. 1,300-1,600 \u00d7 700-900 \u00d7 1,300-1,700 mm<\/td><\/tr><tr><th scope=\"row\">Oil-immersed, total weight<\/th><td>approx. 1,000-1,200 kg<\/td><\/tr><tr><th scope=\"row\">Oil quantity<\/th><td>typically 150-200 litres<\/td><\/tr><tr><th scope=\"row\">Reference: 100 kVA unit<\/th><td>1,000-1,200 \u00d7 500-700 \u00d7 1,100-1,400 mm, 600-900 kg<\/td><\/tr><tr><th scope=\"row\">Dry-type<\/th><td>no oil; larger footprint for air clearance<\/td><\/tr><\/tbody><\/table><\/div><\/section>\n<section class=\"subian-semv2-acbr\" aria-labelledby=\"subian-semv2-acbr-title\"><h2 id=\"subian-semv2-acbr-title\" style=\"font-size:26px;line-height:1.35;\">175 kVA Transformer Price, Sale and Budget Planning<\/h2><p>The 175 kVA transformer price is driven by voltage class, loss level, winding material and the accessory package rather than by the kVA figure alone. As a planning range, a standard oil-immersed 11kV\/0.4kV 175 kVA unit with copper windings and routine test documentation typically falls in the region of USD 3,000-8,000 ex-works; a dry-type or low-loss version, a 33kV primary or a unit with extra protection and metering moves toward the upper end.<\/p><p>If you are looking for a 175 kVA transformer for sale within a fixed budget, the practical news is that this rating sits well inside the common capital budget for distribution equipment &#8211; a requirement of a 175 kVA transformer under $20,000 can cover a fully specified oil-immersed unit with test reports, export packing and freight to most destinations. To buy a 175 kVA transformer with an accurate price, send the primary and secondary voltage, connection group, loss level, mounting arrangement and destination port, and we will issue a written quotation against that specification.<\/p><h3 class=\"subian-semv2-acbr-subtitle\">What moves the 175 kVA price<\/h3><div class=\"subian-semv2-acbr-table-wrap\"><table class=\"subian-semv2-acbr-specs\"><tbody><tr><th scope=\"row\">Voltage class<\/th><td>11kV vs 20kV vs 33kV primary insulation level<\/td><\/tr><tr><th scope=\"row\">Loss level<\/th><td>standard vs low-loss core and conductor design<\/td><\/tr><tr><th scope=\"row\">Winding material<\/th><td>copper vs aluminium windings<\/td><\/tr><tr><th scope=\"row\">Construction<\/th><td>oil-immersed vs dry-type cast resin<\/td><\/tr><tr><th scope=\"row\">Accessories<\/th><td>protection, metering, off-circuit tap link, cable box<\/td><\/tr><tr><th scope=\"row\">Scope<\/th><td>ex-works vs delivered with freight and documents<\/td><\/tr><\/tbody><\/table><\/div><\/section>\n<section class=\"subian-semv2-acbr\" aria-labelledby=\"subian-semv2-acbr-title\"><h2 id=\"subian-semv2-acbr-title\" style=\"font-size:26px;line-height:1.35;\">New, Used and Replacement 175 kVA Transformers<\/h2><p>Most 175 kVA enquiries fall into one of three situations: a new installation, a like-for-like replacement, or an urgent swap after a failure. Whether you searched for a &#8220;price 175 kVA transformer&#8221; quote, a &#8220;175 kVA transformer sale&#8221; listing, a &#8220;nearby 175 kVA transformer&#8221; or a &#8220;replacement 175 kVA transformer&#8221;, the data that decides the answer is the same: nameplate rating, primary and secondary voltage, connection group, impedance and tap range. For a replacement unit the fastest route is to match the existing nameplate data, because the cables, protection settings and mounting hardware are already built around those values, and a new 175 kVA transformer built to the same data drops into the installation with no re-engineering.<\/p><p>A used 175 kVA transformer is worth considering only with a documented history: oil test results (dielectric strength and moisture), winding resistance and ratio measurements, and a record of the loading it has seen. Without those, the saving is usually smaller than the risk, because a failed unit costs more in downtime than the price difference. If you need a 175 kVA transformer nearby, ask about ex-stock availability and lead time: standard ratings can often ship from stock in weeks, while a project rating such as 175 kVA is normally built to order, and we will confirm the production slot with the quotation.<\/p><h3 class=\"subian-semv2-acbr-subtitle\">Choosing between new, used and rebuilt<\/h3><div class=\"subian-semv2-acbr-table-wrap\"><table class=\"subian-semv2-acbr-specs\"><tbody><tr><th scope=\"row\">New, matched to nameplate<\/th><td>fastest drop-in for a replacement; full test report<\/td><\/tr><tr><th scope=\"row\">New, uprated<\/th><td>adds capacity margin; check protection and cable ratings<\/td><\/tr><tr><th scope=\"row\">Used with test records<\/th><td>lower cost; insist on oil and winding test data<\/td><\/tr><tr><th scope=\"row\">Used without records<\/th><td>avoid for critical supply duty<\/td><\/tr><tr><th scope=\"row\">Ex-stock vs built to order<\/th><td>confirm lead time before committing to a date<\/td><\/tr><\/tbody><\/table><\/div><\/section>\n<section class=\"subian-semv2-acbr\" aria-labelledby=\"subian-semv2-acbr-title\"><h2 id=\"subian-semv2-acbr-title\" style=\"font-size:26px;line-height:1.35;\">Distribution, Isolation and 3-Phase Duty<\/h2><p>A distribution transformer 175 kVA unit is the standard duty, stepping the network voltage down for a load area or a single customer. An isolation transformer 175 kVA serves a different purpose: a 175 kVA isolation transformer provides galvanic separation between primary and secondary for safety, noise or harmonic reasons, and it may be specified as 1:1 ratio rather than as a step-down. Isolation units are common in medical, marine, data-centre and workshop applications. In North American catalogues this equipment is classified under voltage transformers &amp; regulators, 175 kVA transformer ratings included; the underlying hardware is the same oil-immersed or dry-type construction, but the specification emphasis shifts to shielding, electrostatic screens and insulation level, so always state the application when you enquire.<\/p><p>A 175 kVA 3 phase transformer is the normal configuration for this rating, since three-phase supply is what industrial, commercial and mixed residential networks use &#8211; single-phase units are built mainly in the smaller rural sizes.<\/p><h3 class=\"subian-semv2-acbr-subtitle\">Duty types at 175 kVA<\/h3><div class=\"subian-semv2-acbr-table-wrap\"><table class=\"subian-semv2-acbr-specs\"><tbody><tr><th scope=\"row\">Distribution step-down<\/th><td>11\/0.4kV, 20\/0.4kV, 33\/0.4kV network supply<\/td><\/tr><tr><th scope=\"row\">175 kVA 3 phase transformer<\/th><td>standard configuration for this rating<\/td><\/tr><tr><th scope=\"row\">175 kVA isolation transformer<\/th><td>galvanic separation, shielding, harmonic isolation<\/td><\/tr><tr><th scope=\"row\">Autotransformer<\/th><td>voltage matching where isolation is not required<\/td><\/tr><\/tbody><\/table><\/div><\/section>\n<section class=\"subian-semv2-acbr\" aria-labelledby=\"subian-semv2-acbr-title\"><h2 id=\"subian-semv2-acbr-title\" style=\"font-size:26px;line-height:1.35;\">Colour, Finish and Enclosure Options<\/h2><p>Transformer colour is usually a specification line rather than a stock feature, and the common requests map directly to RAL numbers: a gray 175 kVA transformer is normally RAL 7035 (light grey) or RAL 7032 (pebble grey), a black 175 kVA transformer is RAL 9005, and a white 175 kVA transformer is RAL 9010. A silver 175 kVA transformer usually means a galvanised or aluminium-finish tank, while a bronze 175 kVA transformer is a bronze-toned paint or a weathered-copper aesthetic used on installations where the equipment is visible to the public.<\/p><p>Finish matters beyond appearance: the tank is shot-blasted and primed before topcoat, and for coastal or high-humidity sites a heavier paint system or hot-dip galvanised fittings extend service life. Colour and finish are agreed at order stage at no extra engineering cost on a factory-direct build, so specify the RAL reference and the environment (indoor, outdoor, coastal, industrial) rather than relying on a colour name alone.<\/p><h3 class=\"subian-semv2-acbr-subtitle\">Common colour and finish requests<\/h3><div class=\"subian-semv2-acbr-table-wrap\"><table class=\"subian-semv2-acbr-specs\"><tbody><tr><th scope=\"row\">Gray<\/th><td>RAL 7035 light grey \/ RAL 7032 pebble grey<\/td><\/tr><tr><th scope=\"row\">Black<\/th><td>RAL 9005<\/td><\/tr><tr><th scope=\"row\">White<\/th><td>RAL 9010<\/td><\/tr><tr><th scope=\"row\">Silver<\/th><td>galvanised or aluminium finish<\/td><\/tr><tr><th scope=\"row\">Bronze<\/th><td>bronze-tone paint for visible installations<\/td><\/tr><tr><th scope=\"row\">Coastal \/ industrial<\/th><td>heavier paint system or hot-dip galvanised fittings<\/td><\/tr><\/tbody><\/table><\/div><\/section>\n<section class=\"subian-semv2-acbr\" aria-labelledby=\"subian-semv2-acbr-title\"><h2 id=\"subian-semv2-acbr-title\" style=\"font-size:26px;line-height:1.35;\">How to Size a Transformer: Calculating kVA<\/h2><p>How to calculate kVA of a transformer from a known load is a two-step sum: add the connected loads in kW, divide by the power factor to convert to kVA, then add a margin for future growth. A load of 130 kW at 0.85 power factor needs about 153 kVA, so the next size up &#8211; here a 175 kVA transformer &#8211; leaves a sensible margin without paying for capacity the site will not use. For motor loads, add the starting duty and check the voltage dip during direct-on-line starts.<\/p><p>On how to size a transformer kVA for a replacement, the reverse also applies: read the nameplate kVA, then verify the actual maximum demand against it. Oversized units run at low load and lose efficiency, while undersized units overheat. As a comparison point, the standard steps around this rating are 125 kVA, 150 kVA and 200 kVA &#8211; a 150 kVA transformer dimensions are close to the 175 kVA figures above, so a size change usually fits the same plinth. For much larger projects, our range extends to 2,500 kVA and separate power transformer pages cover higher ratings and the 1750 kVA transformer price bracket.<\/p><h3 class=\"subian-semv2-acbr-subtitle\">Standard steps around 175 kVA (400V secondary current)<\/h3><div class=\"subian-semv2-acbr-table-wrap\"><table class=\"subian-semv2-acbr-specs\"><tbody><tr><th scope=\"row\">125 kVA<\/th><td>approx. 180 A<\/td><\/tr><tr><th scope=\"row\">150 kVA<\/th><td>approx. 217 A<\/td><\/tr><tr><th scope=\"row\">175 kVA (project rating)<\/th><td>approx. 253 A<\/td><\/tr><tr><th scope=\"row\">200 kVA<\/th><td>approx. 289 A<\/td><\/tr><tr><th scope=\"row\">250 kVA<\/th><td>approx. 361 A<\/td><\/tr><tr><th scope=\"row\">Larger power ratings<\/th><td>1750 kVA and above &#8211; see the power transformer range<\/td><\/tr><\/tbody><\/table><\/div><\/section>\n<section class=\"subian-semv2-acbr\" aria-labelledby=\"subian-semv2-acbr-title\"><h2 id=\"subian-semv2-acbr-title\" style=\"font-size:26px;line-height:1.35;\">175 kVA Transformers and Generator Sets<\/h2><p>A large share of 175 kVA searches come from generator applications rather than network distribution, so it is worth separating the two. When an enquiry starts as a diesel 175 kVA transformer search, it usually turns out to be a generating set requirement: a 175 kVA diesel generator is a common size (roughly 140 kW at 0.8 power factor), and a transformer is frequently bought alongside it to step the generator voltage up to a distribution level or down to a site voltage. If you are matching generators, 175 kVA transformer selection starts with the generator kVA and its voltage so the ratio, impedance and protection are coordinated.<\/p><p>Two related terms are often confused with a 175 kVA transformer. First, a portable 175 kVA transformer: a 175 kVA oil-immersed unit weighs around a tonne and is a fixed installation, so genuinely portable duty is served by a compact dry-type unit or a mobile substation rather than by a standard distribution transformer. Second, a 175 a rating kva transformer entry on a drawing: 175 A is a current, not a capacity &#8211; at 400V, 175 A corresponds to about 121 kVA, while a 175 kVA unit carries about 253 A at 400V. The same applies to a 15 a rating 175 kva transformer call-out, which is a protection or metering figure rather than a transformer size &#8211; size the unit from the kVA or kW demand, not from the current figure alone.<\/p><h3 class=\"subian-semv2-acbr-subtitle\">Don&#8217;t mix up these ratings<\/h3><div class=\"subian-semv2-acbr-table-wrap\"><table class=\"subian-semv2-acbr-specs\"><tbody><tr><th scope=\"row\">175 kVA transformer<\/th><td>approx. 253 A at 400V; approx. 140 kW at 0.8 pf<\/td><\/tr><tr><th scope=\"row\">175 kVA generator set<\/th><td>a different machine &#8211; about 140 kW electrical output<\/td><\/tr><tr><th scope=\"row\">175 A at 400V<\/th><td>only about 121 kVA &#8211; a current, not a capacity<\/td><\/tr><tr><th scope=\"row\">15 A at 400V<\/th><td>about 10 kVA; a protection or metering rating, not a transformer size<\/td><\/tr><tr><th scope=\"row\">Portable duty<\/th><td>use a compact dry-type or mobile substation, not an oil unit<\/td><\/tr><\/tbody><\/table><\/div><\/section>\n\n<section class=\"subian-semv2-factory\" aria-labelledby=\"subian-semv2-factory-title\">\n<div class=\"subian-semv2-factory-head\">\n<h2 id=\"subian-semv2-factory-title\" class=\"subian-semv2-factory-title\">Distribution Transformer Production and Testing<\/h2>\n<p class=\"subian-semv2-factory-intro\">Every 175 kVA unit runs through the same controlled line as our standard ratings &#8211; winding, vacuum drying, oil filling and routine testing.<\/p>\n<\/div>\n<div class=\"subian-semv2-factory-gallery\">\n<div class=\"subian-semv2-factory-item subian-semv2-factory-item--a\"><img decoding=\"async\" class=\"subian-semv2-bg-img\" src=\"\/wp-content\/uploads\/2026\/08\/subian-electric-transformer-winding-process.webp\" alt=\"Winding &amp; Core - 175 kVA Transformer manufacturing\" loading=\"lazy\" \/><h3 class=\"subian-semv2-factory-card-title\">Winding &amp; Core<\/h3><p class=\"subian-semv2-factory-card-text\">Coils wound and dried to the approved design for repeatable losses.<\/p><p><a class=\"subian-semv2-factory-link\" href=\"\/about-us\/\">Learn More \u2192<\/a><\/p><\/div><div class=\"subian-semv2-factory-item subian-semv2-factory-item--b\"><img decoding=\"async\" class=\"subian-semv2-bg-img\" src=\"\/wp-content\/uploads\/2026\/08\/subian-electric-transformer-drying-process.webp\" alt=\"Vacuum Drying - 175 kVA Transformer manufacturing\" loading=\"lazy\" \/><h3 class=\"subian-semv2-factory-card-title\">Vacuum Drying<\/h3><p class=\"subian-semv2-factory-card-text\">Moisture removed before oil filling to protect the insulation system.<\/p><p><a class=\"subian-semv2-factory-link\" href=\"\/about-us\/\">Learn More \u2192<\/a><\/p><\/div><div class=\"subian-semv2-factory-item subian-semv2-factory-item--c\"><img decoding=\"async\" class=\"subian-semv2-bg-img\" src=\"\/wp-content\/uploads\/2026\/08\/subian-electric-transformer-testing-process.webp\" alt=\"Routine Testing - 175 kVA Transformer manufacturing\" loading=\"lazy\" \/><h3 class=\"subian-semv2-factory-card-title\">Routine Testing<\/h3><p class=\"subian-semv2-factory-card-text\">Ratio, vector group, losses, impedance and insulation checks per unit.<\/p><p><a class=\"subian-semv2-factory-link\" href=\"\/about-us\/\">Learn More \u2192<\/a><\/p><\/div><div class=\"subian-semv2-factory-item subian-semv2-factory-item--d\"><img decoding=\"async\" class=\"subian-semv2-bg-img\" src=\"\/wp-content\/uploads\/2026\/08\/subian-electric-transformer-final-process.webp\" alt=\"Packing &amp; Delivery - 175 kVA Transformer manufacturing\" loading=\"lazy\" \/><h3 class=\"subian-semv2-factory-card-title\">Packing &amp; Delivery<\/h3><p class=\"subian-semv2-factory-card-text\">Export packing with lifting points and documents for site installation.<\/p><p><a class=\"subian-semv2-factory-link\" href=\"\/about-us\/\">Learn More \u2192<\/a><\/p><\/div>\n<\/div>\n<\/section>\n\n<section class=\"subian-semv2-cta\" aria-labelledby=\"subian-semv2-cta-title\">\n<div class=\"subian-semv2-cta-content\">\n<h2 id=\"subian-semv2-cta-title\">175 kVA Transformer Price &amp; Quotation<\/h2>\n<p>Send the primary and secondary voltage, connection group, loss level, mounting arrangement and destination port. Our engineers will confirm the 175 kVA specification with dimensions, weight and a written factory quotation.<\/p>\n<div class=\"subian-semv2-cta-actions\"><a class=\"subian-semv2-cta-btn subian-semv2-cta-btn--light\" href=\"\/oem-odm\/\">Get Started \u2192<\/a><br \/><a class=\"subian-semv2-cta-btn subian-semv2-cta-btn--red\" href=\"\/contact-us\/\">Contact Us \u2192<\/a><\/div>\n<\/div>\n<\/section>\n\n<section class=\"subian-semv2-section\" aria-labelledby=\"subian-semv2-title\">\n<div class=\"subian-semv2-head\">\n<h2 id=\"subian-semv2-title\" class=\"subian-semv2-head-title\">OEM \/ ODM &amp; Distribution Supply<\/h2>\n<p class=\"subian-semv2-head-intro\">Utilities, contractors and equipment distributors buy 175 kVA transformers as single units or as repeat project supply.<\/p>\n<\/div>\n<div class=\"subian-semv2-grid\">\n<article class=\"subian-semv2-card\"><img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/08\/subian-electric-transformer-winding-process.webp\" alt=\"OEM \/ ODM - 175 kVA Transformer\" loading=\"lazy\" \/><div class=\"subian-semv2-card-body\"><div class=\"subian-semv2-card-top\"><h3 class=\"subian-semv2-card-title\">OEM \/ ODM<\/h3><p><span class=\"subian-semv2-card-tag\">Factory-Direct<\/span><\/p><\/div><p class=\"subian-semv2-card-desc\">Nameplates, documentation and packaging to your brand.<\/p><hr class=\"subian-semv2-card-line\" \/><p class=\"subian-semv2-card-features\">Factory direct \u00b7 Test docs \u00b7 Export support<\/p><\/div><\/article><article class=\"subian-semv2-card\"><img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/08\/subian-electric-quality-center.webp\" alt=\"Project Supply - 175 kVA Transformer\" loading=\"lazy\" \/><div class=\"subian-semv2-card-body\"><div class=\"subian-semv2-card-top\"><h3 class=\"subian-semv2-card-title\">Project Supply<\/h3><p><span class=\"subian-semv2-card-tag\">Bundled Supply<\/span><\/p><\/div><p class=\"subian-semv2-card-desc\">Transformers, panels and protection coordinated from one factory.<\/p><hr class=\"subian-semv2-card-line\" \/><p class=\"subian-semv2-card-features\">Factory direct \u00b7 Test docs \u00b7 Export support<\/p><\/div><\/article><article class=\"subian-semv2-card\"><img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/08\/subian-electric-transformer-final-process.webp\" alt=\"Distributor Support - 175 kVA Transformer\" loading=\"lazy\" \/><div class=\"subian-semv2-card-body\"><div class=\"subian-semv2-card-top\"><h3 class=\"subian-semv2-card-title\">Distributor Support<\/h3><p><span class=\"subian-semv2-card-tag\">Channel Partners<\/span><\/p><\/div><p class=\"subian-semv2-card-desc\">Price lists, technical data and tender documentation.<\/p><hr class=\"subian-semv2-card-line\" \/><p class=\"subian-semv2-card-features\">Factory direct \u00b7 Test docs \u00b7 Export support<\/p><\/div><\/article>\n<\/div>\n<\/section>\n\n<section class=\"subian-semv2-compare\" aria-labelledby=\"subian-semv2-compare-title\">\n<div class=\"subian-semv2-compare-row\">\n<div class=\"subian-semv2-compare-text\">\n<h2 id=\"subian-semv2-compare-title\">175 kVA vs Standard Ratings<\/h2>\n<p>The standard steps around this rating are 125 kVA, 150 kVA, 160 kVA, 200 kVA and 250 kVA. Choosing 175 kVA normally means matching an existing installation or meeting a network specification, and the physical size and mounting hardware are close enough to the neighbouring steps that the change usually fits the same pole or plinth.<\/p>\n<p>If the load is expected to grow, moving up to 200 kVA or 250 kVA in the same frame is often cheaper than replacing the unit later &#8211; but check the upstream fuse or breaker rating, the cable size and the pole loading before deciding, because the fault level and the weight both rise with capacity.<\/p>\n<\/div>\n<div class=\"subian-semv2-compare-media\"><img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/08\/dry-type-distribution-transformer-6-10-KV-SCB-series-epoxy-resin-cast-2.webp\" alt=\"175 kVA dry-type cast resin distribution transformer option for indoor installation\" loading=\"lazy\" \/><\/div>\n<\/div>\n<\/section>\n\n<section class=\"subian-semv2-brands\" aria-labelledby=\"subian-semv2-brands-title\">\n<div class=\"subian-semv2-brands-row\">\n<div class=\"subian-semv2-brands-media\"><img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/08\/10kV-Dry-Type-Transformer-SCBH-series-Amorphous-Alloy-1.webp\" alt=\"Subian 175 kVA transformer manufacturer oil-immersed and dry-type series\" loading=\"lazy\" \/><\/div>\n<div class=\"subian-semv2-brands-text\">\n<h2 id=\"subian-semv2-brands-title\">Choosing a Supplier for This Rating<\/h2>\n<p>For a project rating such as 175 kVA, confirm that the factory actually builds the full range rather than forcing you to a catalogue step, and ask for the routine test report format, the loss guarantee and the drawing approval process before ordering.<\/p>\n<p>Subian manufactures under ISO9001, ISO14001 and ISO45001 systems with CE and UL certification, and supplies oil-immersed and dry-type distribution transformers from 30 kVA to 2,500 kVA with test documentation for each unit.<\/p>\n<p>Delivery and documentation decide the total cost as much as the unit price: confirm the export packing, the test report set and the lead time with the quotation so the site programme is not held up at the port.<\/p>\n<div class=\"hy-lb-btn-wrap\"><a class=\"hy-lb-btn\" href=\"\/contact-us\/\">Get a Quote \u2192<\/a><\/div>\n<\/div>\n<\/div>\n<\/section>\n\n<section class=\"subian-semv2-cred\" aria-labelledby=\"subian-semv2-cred-title\">\n<div class=\"subian-semv2-cred-head\">\n<h2 id=\"subian-semv2-cred-title\" class=\"subian-semv2-cred-title\">Certifications &amp; Quality Assurance<\/h2>\n<p class=\"subian-semv2-cred-intro\">Distribution transformer production runs under ISO9001, ISO14001 and ISO45001 systems with CE and UL certification and routine test documentation for every unit.<\/p>\n<\/div>\n<h3 class=\"subian-semv2-cred-subtitle\">Product Certifications<\/h3>\n<div class=\"swiper subian-ab-cert-swiper\"><div class=\"swiper-wrapper\"><div class=\"swiper-slide\" role=\"group\" aria-label=\"1 \/ 10\"><a href=\"https:\/\/subian-electric.com\/wp-content\/uploads\/2026\/08\/subian-electric-10kv-dry-type-certificate.webp\" class=\"subian-ab-cert glightbox3\" data-gallery=\"subian-about-certificates\" data-title=\"10 kV Dry-Type Transformer Certificate\"><span><img width=\"600\" height=\"848\" src=\"https:\/\/subian-electric.com\/wp-content\/uploads\/2026\/08\/subian-electric-10kv-dry-type-certificate.webp\" class=\"attachment-large size-large\" alt=\"10 kV Dry-Type Transformer Certificate\" loading=\"lazy\" decoding=\"async\"><\/span><strong class=\"f18 lh-13\">10 kV Dry-Type Transformer Certificate<\/strong><\/a><\/div><div class=\"swiper-slide\" role=\"group\" aria-label=\"2 \/ 10\"><a href=\"https:\/\/subian-electric.com\/wp-content\/uploads\/2026\/08\/subian-electric-35kv-cb-certificate.webp\" class=\"subian-ab-cert glightbox3\" data-gallery=\"subian-about-certificates\" data-title=\"35 kV Transformer CB Certificate\"><span><img width=\"600\" height=\"848\" src=\"https:\/\/subian-electric.com\/wp-content\/uploads\/2026\/08\/subian-electric-35kv-cb-certificate.webp\" class=\"attachment-large size-large\" alt=\"35 kV Transformer CB Certificate\" loading=\"lazy\" decoding=\"async\"><\/span><strong class=\"f18 lh-13\">35 kV Transformer CB Certificate<\/strong><\/a><\/div><div class=\"swiper-slide\" role=\"group\" aria-label=\"3 \/ 10\"><a href=\"https:\/\/subian-electric.com\/wp-content\/uploads\/2026\/08\/subian-electric-35kv-ce-certificate.webp\" class=\"subian-ab-cert glightbox3\" data-gallery=\"subian-about-certificates\" data-title=\"35 kV Transformer CE Verification\"><span><img width=\"600\" height=\"848\" src=\"https:\/\/subian-electric.com\/wp-content\/uploads\/2026\/08\/subian-electric-35kv-ce-certificate.webp\" class=\"attachment-large size-large\" alt=\"35 kV Transformer CE Verification\" loading=\"lazy\" decoding=\"async\"><\/span><strong class=\"f18 lh-13\">35 kV Transformer CE Verification<\/strong><\/a><\/div><div class=\"swiper-slide\" role=\"group\" aria-label=\"4 \/ 10\"><a href=\"https:\/\/subian-electric.com\/wp-content\/uploads\/2026\/08\/subian-electric-ce-certificate.webp\" class=\"subian-ab-cert glightbox3\" data-gallery=\"subian-about-certificates\" data-title=\"Transformer CE Certificate\"><span><img width=\"600\" height=\"848\" src=\"https:\/\/subian-electric.com\/wp-content\/uploads\/2026\/08\/subian-electric-ce-certificate.webp\" class=\"attachment-large size-large\" alt=\"Transformer CE Certificate\" loading=\"lazy\" decoding=\"async\"><\/span><strong class=\"f18 lh-13\">Transformer CE Certificate<\/strong><\/a><\/div><div class=\"swiper-slide\" role=\"group\" aria-label=\"5 \/ 10\"><a href=\"https:\/\/subian-electric.com\/wp-content\/uploads\/2026\/08\/subian-electric-cn26i11c-certificate.webp\" class=\"subian-ab-cert glightbox3\" data-gallery=\"subian-about-certificates\" data-title=\"Dry-Type Transformer Test Verification\"><span><img width=\"600\" height=\"848\" src=\"https:\/\/subian-electric.com\/wp-content\/uploads\/2026\/08\/subian-electric-cn26i11c-certificate.webp\" class=\"attachment-large size-large\" alt=\"Dry-Type Transformer Test Verification\" loading=\"lazy\" decoding=\"async\"><\/span><strong class=\"f18 lh-13\">Dry-Type Transformer Test Verification<\/strong><\/a><\/div><div class=\"swiper-slide\" role=\"group\" aria-label=\"6 \/ 10\"><a href=\"https:\/\/subian-electric.com\/wp-content\/uploads\/2026\/08\/subian-electric-iso-14001-certificate.webp\" class=\"subian-ab-cert glightbox3\" data-gallery=\"subian-about-certificates\" data-title=\"ISO 14001 Environmental Management\"><span><img width=\"600\" height=\"848\" src=\"https:\/\/subian-electric.com\/wp-content\/uploads\/2026\/08\/subian-electric-iso-14001-certificate.webp\" class=\"attachment-large size-large\" alt=\"ISO 14001 Environmental Management\" loading=\"lazy\" decoding=\"async\"><\/span><strong class=\"f18 lh-13\">ISO 14001 Environmental Management<\/strong><\/a><\/div><div class=\"swiper-slide\" role=\"group\" aria-label=\"7 \/ 10\"><a href=\"https:\/\/subian-electric.com\/wp-content\/uploads\/2026\/08\/subian-electric-iso-45001-certificate.webp\" class=\"subian-ab-cert glightbox3\" data-gallery=\"subian-about-certificates\" data-title=\"ISO 45001 Health &amp; Safety\"><span><img width=\"600\" height=\"848\" src=\"https:\/\/subian-electric.com\/wp-content\/uploads\/2026\/08\/subian-electric-iso-45001-certificate.webp\" class=\"attachment-large size-large\" alt=\"ISO 45001 Health &amp; Safety\" loading=\"lazy\" decoding=\"async\"><\/span><strong class=\"f18 lh-13\">ISO 45001 Health &amp; Safety<\/strong><\/a><\/div><div class=\"swiper-slide\" role=\"group\" aria-label=\"8 \/ 10\"><a href=\"https:\/\/subian-electric.com\/wp-content\/uploads\/2026\/08\/subian-electric-iso-9001-certificate.webp\" class=\"subian-ab-cert glightbox3\" data-gallery=\"subian-about-certificates\" data-title=\"ISO 9001 Quality Management\"><span><img width=\"600\" height=\"848\" src=\"https:\/\/subian-electric.com\/wp-content\/uploads\/2026\/08\/subian-electric-iso-9001-certificate.webp\" class=\"attachment-large size-large\" alt=\"ISO 9001 Quality Management\" loading=\"lazy\" decoding=\"async\"><\/span><strong class=\"f18 lh-13\">ISO 9001 Quality Management<\/strong><\/a><\/div><div class=\"swiper-slide\" role=\"group\" aria-label=\"9 \/ 10\"><a href=\"https:\/\/subian-electric.com\/wp-content\/uploads\/2026\/08\/subian-electric-ssz22-63000-110-nx1-certificate.webp\" class=\"subian-ab-cert glightbox3\" data-gallery=\"subian-about-certificates\" data-title=\"110 kV Transformer Type Test Report\"><span><img width=\"600\" height=\"848\" src=\"https:\/\/subian-electric.com\/wp-content\/uploads\/2026\/08\/subian-electric-ssz22-63000-110-nx1-certificate.webp\" class=\"attachment-large size-large\" alt=\"110 kV Transformer Type Test Report\" loading=\"lazy\" decoding=\"async\"><\/span><strong class=\"f18 lh-13\">110 kV Transformer Type Test Report<\/strong><\/a><\/div><div class=\"swiper-slide\" role=\"group\" aria-label=\"10 \/ 10\"><a href=\"https:\/\/subian-electric.com\/wp-content\/uploads\/2026\/08\/subian-electric-ul-certificate.webp\" class=\"subian-ab-cert glightbox3\" data-gallery=\"subian-about-certificates\" data-title=\"UL Certificate of Compliance\"><span><img width=\"600\" height=\"848\" src=\"https:\/\/subian-electric.com\/wp-content\/uploads\/2026\/08\/subian-electric-ul-certificate.webp\" class=\"attachment-large size-large\" alt=\"UL Certificate of Compliance\" loading=\"lazy\" decoding=\"async\"><\/span><strong class=\"f18 lh-13\">UL Certificate of Compliance<\/strong><\/a><\/div><\/div><\/div>\n<p> <\/p>\n<\/section>\n\n<section class=\"subian-related\" style=\"margin: 40px 0;\">\n<div style=\"max-width: 1200px; margin: 0 auto; padding: 0 24px;\">\n<h2 style=\"font-size: 24px; margin-bottom: 12px;\">Related Manufacturer Guides<\/h2>\n<ul style=\"columns: 2; column-gap: 48px; margin: 0; padding-left: 20px; line-height: 2;\">\n<li><a href=\"\/40-mva-transformer\/\">40 MVA Transformer<\/a><\/li><li><a href=\"\/1750-kva-transformer\/\">1750 kVA Transformer<\/a><\/li><li><a href=\"\/450-kva-transformer\/\">450 kVA Transformer<\/a><\/li><li><a href=\"\/150-kva-step-down-transformer\/\">150 kVA Step Down Transformer<\/a><\/li><li><a href=\"\/330-kva-transformer\/\">330 kVA Transformer<\/a><\/li><li><a href=\"\/33kv-voltage-transformer\/\">33kV Voltage Transformer<\/a><\/li>\n<\/ul>\n<\/div>\n<\/section>\n\n<section class=\"subian-faq-contact\">\n<div class=\"subian-faq-contact__container\">\n<div class=\"subian-faq-contact__grid\">\n<div class=\"subian-faq-contact__left\"><span class=\"subian-faq-contact__eyebrow\">FAQs<\/span>\n<h2 class=\"subian-faq-contact__title\">175 kVA Transformer FAQ<\/h2>\n<p class=\"subian-faq-contact__intro\">Common questions about the 175 kVA rating and the standard sizes around it &#8211; current, availability and how much load a unit can carry.<\/p>\n<div class=\"subian-faq\"><details class=\"subian-faq__item\"><summary class=\"subian-faq__question\">How many amps is a 150 kVA transformer good for?<\/summary><div class=\"subian-faq__answer\">A 150 kVA three-phase transformer carries about 217 A per phase on a 400V secondary, about 209 A at 415V, about 180 A at 480V and about 361 A at 240V. On the primary side the current is much lower: roughly 7.9 A at 11 kV and 4.3 A at 20 kV. The current depends on the secondary voltage, so always quote the winding voltage when specifying cables or protection.<\/div><\/details><details class=\"subian-faq__item\"><summary class=\"subian-faq__question\">Is there a 200 kVA transformer?<\/summary><div class=\"subian-faq__answer\">Yes. 200 kVA is one of the standard preferred ratings, and it is widely used for commercial and light industrial distribution. Its full-load current is about 289 A per phase at 400V. We build 200 kVA units on the same platform as the rest of the 30-2,500 kVA range, in oil-immersed or dry-type construction, so it can be supplied with the same connection groups and impedance as a 175 kVA unit when a project standardises on one design.<\/div><\/details><details class=\"subian-faq__item\"><summary class=\"subian-faq__question\">Is there a 125 kVA transformer?<\/summary><div class=\"subian-faq__answer\">Yes, 125 kVA is also a standard rating and a common step below 175 kVA. It carries about 180 A per phase at 400V and about 6.6 A at 11 kV. Where a load calculation lands between 125 kVA and 175 kVA, the choice usually comes down to the growth margin: 125 kVA suits a stable load, while 175 kVA gives headroom for future extension without changing the mounting arrangement.<\/div><\/details><details class=\"subian-faq__item\"><summary class=\"subian-faq__question\">How many houses can a 100 kVA transformer handle?<\/summary><div class=\"subian-faq__answer\">It depends on the demand per house rather than on a fixed number. A 100 kVA transformer supplies about 80 kW at 0.8 power factor. At a typical 2.5 kW diversified demand per house that is roughly 30-32 houses; at 5 kW per house it is about 16 houses; and in areas with heavy electric heating or air-conditioning (8 kW or more per house) it falls to around 10 houses. Apply the local diversity factor and the utility&#8217;s design rule &#8211; and if the development is still growing, a 175 kVA unit in the same footprint gives useful extra margin.<\/div><\/details><\/div>\n<\/div>\n<div class=\"subian-faq-contact__form\">\n<p class=\"subian-faq-contact__form-label\">Contact Subian<\/p>\n<h3 class=\"subian-faq-contact__form-title\">Need the Right Specification?<\/h3>\n<p class=\"subian-faq-contact__form-copy\">Tell us your target market, product type, quantity and technical requirements. Our team will help you identify a suitable configuration for your project.<\/p>\n<div class='fluentform ff-default fluentform_wrapper_1 ffs_default_wrap'><form data-form_id=\"1\" id=\"fluentform_1\" class=\"frm-fluent-form fluent_form_1 ff-el-form-top ff_form_instance_1_1 ff-form-loading ffs_default\" data-form_instance=\"ff_form_instance_1_1\" method=\"POST\" ><fieldset  style=\"border: none!important;margin: 0!important;padding: 0!important;background-color: transparent!important;box-shadow: none!important;outline: none!important; min-inline-size: 100%;\">\n                    <legend class=\"ff_screen_reader_title\" style=\"display: block; margin: 0!important;padding: 0!important;height: 0!important;text-indent: -999999px;width: 0!important;overflow:hidden;\">Contact Form Demo<\/legend>        <div\n                style=\"display: none!important; position: absolute!important; transform: translateX(1000%)!important;\"\n                class=\"ff-el-group ff-hpsf-container\"\n        >\n            <div class=\"ff-el-input--label asterisk-right\">\n                <label for=\"ff_1_item_sf\" aria-label=\"Newsletter\">\n                    Newsletter                <\/label>\n            <\/div>\n            <div class=\"ff-el-input--content\">\n                <input type=\"text\"\n                       name=\"item_1__fluent_sf\"\n                       class=\"ff-el-form-control\"\n                       id=\"ff_1_item_sf\"\n                \/>\n            <\/div>\n        <\/div>\n                <input type=\"hidden\" id=\"__fluent_protection_token_1\" class=\"fluent-form-token-field\" name=\"__fluent_protection_token_1\">\n        <input type='hidden' name='__fluent_form_embded_post_id' value='11522' \/><input type=\"hidden\" id=\"_fluentform_1_fluentformnonce\" name=\"_fluentform_1_fluentformnonce\" value=\"e9011d557d\" \/><input type=\"hidden\" name=\"_wp_http_referer\" value=\"\/fr\/wp-json\/wp\/v2\/pages\/11522\" \/><div data-type=\"name-element\" data-name=\"names\" class=\" ff-field_container ff-name-field-wrapper\" ><div class='ff-t-container'><div class='ff-t-cell '><div class='ff-el-group'><div class=\"ff-el-input--label asterisk-right\"><label for='ff_1_names_first_name_' id='label_ff_1_names_first_name_' >First Name<\/label><\/div><div class='ff-el-input--content'><input type=\"text\" name=\"names[first_name]\" id=\"ff_1_names_first_name_\" class=\"ff-el-form-control\" aria-invalid=\"false\" aria-required=false><\/div><\/div><\/div><div class='ff-t-cell '><div class='ff-el-group'><div class=\"ff-el-input--label asterisk-right\"><label for='ff_1_names_last_name_' id='label_ff_1_names_last_name_' >Last Name<\/label><\/div><div class='ff-el-input--content'><input type=\"text\" name=\"names[last_name]\" id=\"ff_1_names_last_name_\" class=\"ff-el-form-control\" aria-invalid=\"false\" aria-required=false><\/div><\/div><\/div><\/div><\/div><div class='ff-el-group'><div class=\"ff-el-input--label ff-el-is-required asterisk-right\"><label for='ff_1_email' id='label_ff_1_email' aria-label=\"Email Address\">Email Address<\/label><\/div><div class='ff-el-input--content'><input type=\"email\" name=\"email\" id=\"ff_1_email\" class=\"ff-el-form-control\" data-name=\"email\"  aria-invalid=\"false\" aria-required=true><\/div><\/div><div class='ff-el-group'><div class=\"ff-el-input--label asterisk-right\"><label for='ff_1_subject' id='label_ff_1_subject' aria-label=\"Subject\">Subject<\/label><\/div><div class='ff-el-input--content'><input type=\"text\" name=\"subject\" class=\"ff-el-form-control\" data-name=\"subject\" id=\"ff_1_subject\"  aria-invalid=\"false\" aria-required=false><\/div><\/div><div class='ff-el-group'><div class=\"ff-el-input--label ff-el-is-required asterisk-right\"><label for='ff_1_message' id='label_ff_1_message' aria-label=\"Tell us about your project\">Tell us about your project<\/label><\/div><div class='ff-el-input--content'><textarea aria-required=\"true\" aria-labelledby=\"label_ff_1_message\" name=\"message\" id=\"ff_1_message\" class=\"ff-el-form-control\" rows=\"4\" cols=\"2\" data-name=\"message\" ><\/textarea><\/div><\/div><div class='ff-el-group ff-text-left ff_submit_btn_wrapper'><button type=\"submit\" class=\"ff-btn ff-btn-submit ff-btn-md ff_btn_style\"  aria-label=\"Send message\">Send message<\/button><\/div><\/fieldset><\/form><div id='fluentform_1_errors' class='ff-errors-in-stack ff_form_instance_1_1 ff-form-loading_errors ff_form_instance_1_1_errors'><\/div><\/div>            <script type=\"text\/javascript\">\n                window.fluent_form_ff_form_instance_1_1 = {\"id\":\"1\",\"ajaxUrl\":\"https:\\\/\\\/subian-electric.com\\\/wp-admin\\\/admin-ajax.php\",\"settings\":{\"layout\":{\"labelPlacement\":\"top\",\"helpMessagePlacement\":\"with_label\",\"errorMessagePlacement\":\"inline\",\"cssClassName\":\"\",\"asteriskPlacement\":\"asterisk-right\"},\"restrictions\":{\"denyEmptySubmission\":{\"enabled\":false}}},\"form_instance\":\"ff_form_instance_1_1\",\"form_id_selector\":\"fluentform_1\",\"rules\":{\"names[first_name]\":{\"required\":{\"value\":false,\"message\":\"This field is required\",\"global\":false,\"global_message\":\"This field is required\"}},\"names[middle_name]\":{\"required\":{\"value\":false,\"message\":\"This field is required\",\"global\":false,\"global_message\":\"This field is required\"}},\"names[last_name]\":{\"required\":{\"value\":false,\"message\":\"This field is required\",\"global\":false,\"global_message\":\"This field is required\"}},\"email\":{\"required\":{\"value\":true,\"message\":\"This field is required\",\"global\":false,\"global_message\":\"This field is required\"},\"email\":{\"value\":true,\"message\":\"This field must contain a valid email\",\"global\":false,\"global_message\":\"This field must contain a valid email\"}},\"subject\":{\"required\":{\"value\":false,\"message\":\"This field is required\",\"global\":false,\"global_message\":\"This field is required\"}},\"message\":{\"required\":{\"value\":true,\"message\":\"This field is required\",\"global\":false,\"global_message\":\"This field is required\"}}},\"debounce_time\":300,\"file_upload_settings\":[]};\n                            <\/script>\n            \n<div class=\"subian-faq-contact__trust\">Your inquiry is sent directly to our export sales team.<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<p><script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"How many amps is a 150 kVA transformer good for?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"A 150 kVA three-phase transformer carries about 217 A per phase on a 400V secondary, about 209 A at 415V, about 180 A at 480V and about 361 A at 240V. On the primary side the current is much lower: roughly 7.9 A at 11 kV and 4.3 A at 20 kV. The current depends on the secondary voltage, so always quote the winding voltage when specifying cables or protection.\"}}, {\"@type\": \"Question\", \"name\": \"Is there a 200 kVA transformer?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. 200 kVA is one of the standard preferred ratings, and it is widely used for commercial and light industrial distribution. Its full-load current is about 289 A per phase at 400V. We build 200 kVA units on the same platform as the rest of the 30-2,500 kVA range, in oil-immersed or dry-type construction, so it can be supplied with the same connection groups and impedance as a 175 kVA unit when a project standardises on one design.\"}}, {\"@type\": \"Question\", \"name\": \"Is there a 125 kVA transformer?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes, 125 kVA is also a standard rating and a common step below 175 kVA. It carries about 180 A per phase at 400V and about 6.6 A at 11 kV. Where a load calculation lands between 125 kVA and 175 kVA, the choice usually comes down to the growth margin: 125 kVA suits a stable load, while 175 kVA gives headroom for future extension without changing the mounting arrangement.\"}}, {\"@type\": \"Question\", \"name\": \"How many houses can a 100 kVA transformer handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"It depends on the demand per house rather than on a fixed number. A 100 kVA transformer supplies about 80 kW at 0.8 power factor. At a typical 2.5 kW diversified demand per house that is roughly 30-32 houses; at 5 kW per house it is about 16 houses; and in areas with heavy electric heating or air-conditioning (8 kW or more per house) it falls to around 10 houses. Apply the local diversity factor and the utility's design rule - and if the development is still growing, a 175 kVA unit in the same footprint gives useful extra margin.\"}}]}<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>COMPANY PROFILE 175 kVA Transformer Subian Electric manufactures 175 kVA distribution transformers for 11kV, 20kV and 33kV networks stepping down to 400V. The rating sits between the standard 160 kVA and 200 kVA steps, which makes it a project and replacement size: buyers specify it where an existing unit is being matched, where a load [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"subian-seo-landing.php","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-11522","page","type-page","status-publish","hentry"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/subian-electric.com\/fr\/wp-json\/wp\/v2\/pages\/11522","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/subian-electric.com\/fr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/subian-electric.com\/fr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/subian-electric.com\/fr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/subian-electric.com\/fr\/wp-json\/wp\/v2\/comments?post=11522"}],"version-history":[{"count":1,"href":"https:\/\/subian-electric.com\/fr\/wp-json\/wp\/v2\/pages\/11522\/revisions"}],"predecessor-version":[{"id":11523,"href":"https:\/\/subian-electric.com\/fr\/wp-json\/wp\/v2\/pages\/11522\/revisions\/11523"}],"wp:attachment":[{"href":"https:\/\/subian-electric.com\/fr\/wp-json\/wp\/v2\/media?parent=11522"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}