{"id":10699,"date":"2026-08-29T23:42:53","date_gmt":"2026-08-29T15:42:53","guid":{"rendered":"https:\/\/q8bbzjnpm5.wpdns.site\/?p=10699"},"modified":"2026-08-29T23:42:53","modified_gmt":"2026-08-29T15:42:53","slug":"the-role-of-distribution-transformers-in-modern-energy-systems","status":"publish","type":"post","link":"https:\/\/subian-electric.com\/it\/news\/the-role-of-distribution-transformers-in-modern-energy-systems\/","title":{"rendered":"Il ruolo dei trasformatori di distribuzione nei moderni sistemi energetici"},"content":{"rendered":"<p>A young engineer in charge of planning in a public utility spends her time preparing for next year&#8217;s budget. This involves not merely connecting the new solar park of 40 MW capacity and getting new power connections to 3,000 households built on the perimeter of the city but also achieving the new regulatory requirement to reduce the distribution loss through the existing aging networks. The same equipment keeps appearing at every stage of her plan as something that both enables and constrains her project \u2014 the <strong>distribution transformer<\/strong>. With transformers being unreasonably few in number, feeders are overloaded, expensive old transformers lead to losses, and using the right transformers makes things easier for the entire system.<\/p>\n<p>This article discusses the role of the distribution transformer in modern energy systems, including the functions the transformer fulfills and also some new applications in solar power generation, energy storage, and smart grid technologies; as well as provides some basic information about price structures and standards necessary for potential buyers.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-10702\" src=\"https:\/\/subian-electric.com\/wp-content\/uploads\/2026\/08\/Choosing-the-Right-Distribution-Transformer.webp\" alt=\"\" width=\"1448\" height=\"1086\" \/><\/p>\n<h2 id=\"definition\">What Is a Distribution Transformer?<\/h2>\n<p>The final voltage-changing piece of equipment in the power transmission line is known as a distribution transformer. Generation and transmission happen at higher voltage levels \u2013 110 kV, 220 kV, etc. \u2013 since high voltage causes low current, which leads to reduced losses. However, customers require 400\/230 V (or 120\/240 V), so the process of making the transition from the transmission voltage to a level suitable for the usage needs to be done in several steps. The distribution transformer performs the final and the most crucial step in this transformation process.<\/p>\n<p>Unlike the power transformer used in high-voltage substations, the distribution transformer has different dimensions and different roles. Power transformers (usually over 2,500 kVA) can be found in transmission or sub-transmission substations, while distribution transformers (typically 5 to 2,500 kVA) are situated closer to the consumers (on poles, concrete slabs, or inside the small substations). A medium-size town may have a few power transformers and thousands of distribution transformers.<\/p>\n<p>From physical standpoint, the majority of distribution transformers are oil-cooled (ONAN) and used outdoors, although the dry-type (cast resin) transformers can be found indoors and in places with increased risk of fire. For instance, a three-phase oil-immersed transformer of 100 kVA capacity weighs from 700 kg to 900 kg with a dimension of 1.3 \u00d7 0.9 \u00d7 1.4 m, while 100 kVA dry-type transformer is smaller in size and weight but noisier in operation.<\/p>\n<h2 id=\"role\">The Role of the Distribution Transformer in the Grid<\/h2>\n<p>The distribution transformer performs four jobs in a modern energy system, and each is worth understanding because it changes what you buy:<\/p>\n<table>\n<thead>\n<tr>\n<th>Ruolo<\/th>\n<th>What it does<\/th>\n<th>Example in practice<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Voltage stepping<\/td>\n<td>Reduces 6.6\u201335 kV MV to 400\/230 V or 120\/240 V LV<\/td>\n<td>11\/0.4 kV unit feeding a residential street<\/td>\n<\/tr>\n<tr>\n<td>System separation and earthing<\/td>\n<td>Provides a defined neutral and earth reference for the LV network<\/td>\n<td>Dyn11 vector group creating a solidly earthed LV neutral<\/td>\n<\/tr>\n<tr>\n<td>Load concentration \/ isolation<\/td>\n<td>Enables one MV feeder to serve many small consumers while isolating faults<\/td>\n<td>One faulted street transformer does not black out the feeder<\/td>\n<\/tr>\n<tr>\n<td>Voltage regulation<\/td>\n<td>On-load tap changers maintain LV voltage as load varies<\/td>\n<td>OLTC keeps 400 V within \u00b15% across the daily load curve<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Special mention must be made of the &#8220;system separation&#8221; role. The vector group of a distribution transformer (usually Dyn11 in IEC markets) is what defines how the neutral is grounded. The grounding concept subsequently influences the protective relaying technique on the LV side and its efficiency, which is why it is often the first question a reputable manufacturer will ask you.<\/p>\n<h2 id=\"losses\">Losses and Efficiency: Why They Matter More Than You Think<\/h2>\n<p>In most current electrical distribution systems, distribution transformers represent the biggest individual source of technical losses. According to the International Energy Agency, distribution losses have been assessed at about 4\u20136% of the global output of electricity, with distribution transformers bearing a considerable part of the responsibility. Distribution transformers work the potential maximum of 8,760 hours a year, and hence even small differences in losses translate to big amounts of losses nationwide.<\/p>\n<p>There are two loss components that behave differently:<\/p>\n<p>No-load losses (also called iron loss) \u2013 is a steady and always-present loss. It is defined by the square of the applied voltage and does not change when the electrical load is applied.<br \/>\nLoad losses (also called copper loss) \u2013 are defined by the square of the current consumed by the load and therefore grow in accordance to the loading increase rate.<\/p>\n<p>Modern efficiency standards, such as the European Union Ecodesign legislation, the US Department of Energy regulations, and the GB 20052 in China, impose the reduction of no-load losses. Hence, a distribution transformer belonging to the Grade 1 category, which has an amorphous core, has a possibility of reducing the iron losses to 70\u201380% as compared to a product designed in the 1990s. Thus, for a 630 kVA transformer the aforementioned difference corresponds to the annual savings of $300\u2013600 in electricity costs. The table below demonstrates the annual figures related to energy consumed by a continuously operated 630 kVA transformer installation.<\/p>\n<table>\n<thead>\n<tr>\n<th>Design vintage<\/th>\n<th>Perdita a vuoto (630 kVA)<\/th>\n<th>Iron energy per year<\/th>\n<th>Annual cost at $0.10\/kWh<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1990s (S7-class)<\/td>\n<td>\u2248 1,800\u20132,000 W<\/td>\n<td>\u2248 15,800\u201317,500 kWh<\/td>\n<td>$1,580\u2013$1,750<\/td>\n<\/tr>\n<tr>\n<td>S11-class (Grade 3)<\/td>\n<td>\u2248 1,000\u20131,100 W<\/td>\n<td>\u2248 8,800\u20139,600 kWh<\/td>\n<td>$880\u2013$960<\/td>\n<\/tr>\n<tr>\n<td>S13-class (Grade 2)<\/td>\n<td>\u2248 750\u2013850 W<\/td>\n<td>\u2248 6,600\u20137,400 kWh<\/td>\n<td>$660\u2013$740<\/td>\n<\/tr>\n<tr>\n<td>Amorphous (Grade 1)<\/td>\n<td>\u2248 500\u2013600 W<\/td>\n<td>\u2248 4,400\u20135,300 kWh<\/td>\n<td>$440\u2013$530<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Across a fleet of a few thousand units, choosing Grade 1 amorphous cores instead of S11-class steel quietly saves six figures per year in iron losses alone \u2014 before any load-loss savings are counted.<\/p>\n<h2 id=\"types\">Types of Distribution Transformers<\/h2>\n<p>Buyers choose among several families, and the choice is driven by mounting, environment, and fire safety. The table below summarizes the main types with realistic price bands (FOB, China) for common ratings.<\/p>\n<table>\n<thead>\n<tr>\n<th>Tipo<\/th>\n<th>Ratings<\/th>\n<th>Typical use<\/th>\n<th>Price range (FOB)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Pole-mounted (oil)<\/td>\n<td>5\u2013500 kVA<\/td>\n<td>Rural and suburban overhead networks<\/td>\n<td>$350\u2013$6,500<\/td>\n<\/tr>\n<tr>\n<td>Pad-mounted (oil)<\/td>\n<td>25\u20132.500 kVA<\/td>\n<td>Urban underground networks, locked enclosure<\/td>\n<td>$900\u2013$12,000<\/td>\n<\/tr>\n<tr>\n<td>Dry-type (cast resin)<\/td>\n<td>50\u20132.500 kVA<\/td>\n<td>Buildings, tunnels, hospitals, fire-sensitive sites<\/td>\n<td>$3,500\u2013$30,000<\/td>\n<\/tr>\n<tr>\n<td>Amorphous-core (oil)<\/td>\n<td>15\u20131,000 kVA<\/td>\n<td>Efficiency-driven programs, Grade 1 targets<\/td>\n<td>$900\u2013$15,000<\/td>\n<\/tr>\n<tr>\n<td>Compact box substation transformer<\/td>\n<td>100\u20132,500 kVA<\/td>\n<td>Integrated into box-type stations<\/td>\n<td>$2,500\u2013$18,000<\/td>\n<\/tr>\n<tr>\n<td>Hermetically sealed (oil)<\/td>\n<td>50\u2013630 kVA<\/td>\n<td>Moisture-prone coastal and humid sites<\/td>\n<td>$800\u2013$8,000<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>There are two major trends transforming this catalog. The first trend is the increase of dry-type units in indoor applications due to elimination of fire risk and costs associated with oil containment. The second trend is the use of amorphous core units in efficiency rebate programs, where an additional cost of 15%\u201325% compared to traditional CRGO designs can be recouped over 3\u20136 years of savings.<\/p>\n<h2 id=\"modern\">Modern Roles: Renewables, Storage, and Smart Grid<\/h2>\n<p>The traditional depiction of a distribution transformer as a mere passive device is no longer applicable. Today\u2019s distribution transformers are quickly changing into active elements of electrical supply systems.<br \/>\nSolar and EV integration: Rooftop solar stations and electric vehicle chargers push electricity both ways in the transformer. The two-way flow of current creates new load regimes causing overheating of transformers designed for one-way currents. Some utilities are already reducing the capacity of transformers in areas with high penetration of solar stations by 15-20% or have introduced smart tap changers.<br \/>\nBattery storage integration: Community energy storage stations charge and discharge through the distribution transformer, helping to flatten the load as well as prolonging the service life of transformers.<br \/>\nSmart grid sensing: Modern transformers have internal temperature and oil level sensors and wireless communication devices to provide data on the state of transformers.<br \/>\nDemand flexibility: New smart transformers are equipped with on-load tap changers and remote monitoring systems allowing operational personnel to lower voltage during peak hours (conservation voltage reduction or CVR).<br \/>\nAll these factors change the procurement process: today\u2019s utility tenders often require using devices equipped with monitoring and communication ports compliant with IEC 61850 even for transformers with the power of 100 kVA.<\/p>\n<h2 id=\"specs\">Specifiche e standard chiave<\/h2>\n<p>Every distribution transformer you buy should be specified and tested to the IEC 60076 series (or IEEE C57.12 in the Americas). The critical specification fields for a typical 400 kVA three-phase unit:<\/p>\n<table>\n<thead>\n<tr>\n<th>Parametro<\/th>\n<th>Typical value (400 kVA)<\/th>\n<th>Standard<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Potenza nominale<\/td>\n<td>400 kVA, ONAN<\/td>\n<td>IEC 60076-1<\/td>\n<\/tr>\n<tr>\n<td>Rapporto di tensione<\/td>\n<td>11,000 \u00b1 2\u00d72.5% \/ 400\u2013433 V<\/td>\n<td>IEC 60076-1<\/td>\n<\/tr>\n<tr>\n<td>Gruppo vettoriale<\/td>\n<td>Dyn11<\/td>\n<td>IEC 60076-1<\/td>\n<\/tr>\n<tr>\n<td>Impedenza di cortocircuito<\/td>\n<td>4.5\u20135.0%<\/td>\n<td>IEC 60076-5<\/td>\n<\/tr>\n<tr>\n<td>Perdita a vuoto<\/td>\n<td>\u2264 570\u2013650 W (S11-class)<\/td>\n<td>IEC 60076-1 \/ GB 20052<\/td>\n<\/tr>\n<tr>\n<td>Perdita di carico a 75\u00b0C<\/td>\n<td>\u2264 4,000\u20134,500 W<\/td>\n<td>IEC 60076-1<\/td>\n<\/tr>\n<tr>\n<td>Impulse withstand<\/td>\n<td>75 kVp (LI)<\/td>\n<td>IEC 60076-3<\/td>\n<\/tr>\n<tr>\n<td>Winding temperature rise<\/td>\n<td>\u2264 65 K (average)<\/td>\n<td>IEC 60076-2<\/td>\n<\/tr>\n<tr>\n<td>Livello sonoro<\/td>\n<td>\u2264 52\u201355 dB(A)<\/td>\n<td>IEC 60076-10<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>For US-bound projects, use IEEE C57.12.00 for general requirements and C57.12.20 for pad-mounted units, and check whether NEMA TP-1 efficiency applies in the destination state. For all markets, demand per-unit routine test certificates and design type-test reports.<\/p>\n<h2 id=\"sizing\">Sizing and Load Management<\/h2>\n<p>Proper distribution transformer sizing necessitates a load study; not wild imagination. We can follow the method used by electric utilities worldwide:<\/p>\n<p>Determine the connected load (which is the sum of the total load downstream measured in kW).<br \/>\nAllow for diversity in the connected load (in residential areas one can expect the diversity factor would typically range between 0.4-0.6, while in a commercial area it would be 0.6-0.8).<br \/>\nDivide the sum obtained by the power factor (which is typically between 0.85-0.95 for a mixed load, thus converting kW into kVA).<br \/>\nAdd an additional margin of growth (ranging from 15-25% for future load increases occurring during the transformer life).<br \/>\nCheck the voltage drop (especially on long LV distribution reaches).<\/p>\n<p>As a rule of thumb, one can say that a 100 kVA transformer serves between 60-120 households, a 315 kVA transformer could supply power to a small commercial district or up to 200-400 households, and a 630 kVA transformer supplies power to a district business center or a small industrial zone. Oversizing the transformer means wasting money on no-load losses; undersizing it means the transformer will break sooner. Both errors are much more expensive than moderate engineer\u2019s fees which prevent them from occurring.<\/p>\n<h2 id=\"brands\">Top Brands and Price Ranges<\/h2>\n<p>The market spans premium international brands and cost-competitive Chinese and Indian manufacturers. Prices below are indicative for a 400 kVA three-phase oil-immersed unit, FOB basis.<\/p>\n<table>\n<thead>\n<tr>\n<th>Marca<\/th>\n<th>Paese<\/th>\n<th>400 kVA price range<\/th>\n<th>Note<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>ABB<\/td>\n<td>Svizzera<\/td>\n<td>$14.000\u2013$22.000<\/td>\n<td>Premium quality, global service<\/td>\n<\/tr>\n<tr>\n<td>Siemens<\/td>\n<td>Germania<\/td>\n<td>$13,500\u2013$23,000<\/td>\n<td>Strong smart-grid integration<\/td>\n<\/tr>\n<tr>\n<td>Schneider Electric<\/td>\n<td>Francia<\/td>\n<td>$13,000\u2013$21,000<\/td>\n<td>Complete LV\/MV ecosystem<\/td>\n<\/tr>\n<tr>\n<td>Hitachi Energy<\/td>\n<td>Switzerland\/Japan<\/td>\n<td>$15,000\u2013$24,000<\/td>\n<td>Utility-grade reliability heritage<\/td>\n<\/tr>\n<tr>\n<td>Eaton<\/td>\n<td>Ireland\/USA<\/td>\n<td>$12.000\u2013$20.000<\/td>\n<td>Strong in Americas pad-mounts<\/td>\n<\/tr>\n<tr>\n<td>TBEA \/ China XD<\/td>\n<td>Cina<\/td>\n<td>$5,500\u2013$9,000<\/td>\n<td>Large state-backed manufacturers<\/td>\n<\/tr>\n<tr>\n<td>Jiangsu Subian Energia Elettrica<\/td>\n<td>Cina<\/td>\n<td>$5,000\u2013$8,500<\/td>\n<td>Export-focused, IEC-tested, custom options<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Global companies such as ABB, Siemens, Schneider Electric and Hitachi Energy provide effective dependability, established R&amp;D, digital monitoring systems and service networks that allow them to charge a premium price of 2-2.5x for these warranties for utilities that prefer that.<\/p>\n<p>In applications where the efficiency threshold is just as its important as the name and where the money can really buy two units for the price of one \u2013 Jiangsu Subian Electric Power is a ready-to-use partner. The firm is producing oil-immersed distribution transformers from 5 kVA to 2,500 kVA, as well as dry-type units with a capacity of up to 2,000 kVA, manufactured according to IEC 60076 and provided with a routine test record. Subian provides devices with amorphous cores, unique vector groups and tap ranges, smart monitoring options, and ODM configuration, which can be shipped worldwide and even inspected by third-party inspection companies before the shipment if necessary.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-10701\" src=\"https:\/\/subian-electric.com\/wp-content\/uploads\/2026\/08\/4-Core-Roles-of-Distribution-Transformers.webp\" alt=\"\" width=\"1448\" height=\"1086\" \/><\/p>\n<h2 id=\"buy\">What to Specify When Buying<\/h2>\n<p>Whichever unit you choose to acquire, whether it&#8217;s one unit or more, make sure that the following information is provided in writing:<\/p>\n<p>Cool and voltage: determine kVA rating, whether ONAN is used (or ONAF, if overloaded).<br \/>\nVoltage and tapping: what is the primary voltage, maximum voltage drop in percentage (\u00b12\u00d72.5% or \u00b15%).<br \/>\nVector Group: Dyn11, Yyn0, YNd11 or other according to earthing philosophy.<br \/>\nUpper limits of losses: define, no-load loss rate and working loss; also, write a penalty clause and possible penalties in case of exceeding losses.<br \/>\nStandards and testing: refer to IEC 60076, provide routine limit certificates.<br \/>\nAccessories: if required, provide an option of bushings (porcelain or polymer), a conservator or sealed tank, drain and tap valves, insulation device etc.<br \/>\nMonitoring requirements: specify winding temperature indicator, level of oil, partial discharges, possible communication protocol (IEC61850\/Modbus).<br \/>\nLogistics: determine standard in packing materials, details of lifting and transport, and obligatory check by the relevant inspection authority.<br \/>\nBe careful with tap ratio and vector group, since these items are most common in case of additional costs related to field corrections.<\/p>\n<h2 id=\"faq\">Domande frequenti<\/h2>\n<h3>What is the difference between a distribution transformer and a power transformer?<\/h3>\n<p>The size and purpose. The distribution transformers sizes range from 5 to 2,500 kVA and work on the principles of reducing voltage from the MV range (6.6-35 kV) to the operating voltage at the point of usage. The power transformers provide the option to interconnect the transmission systems with voltages that exceed the range of either 2,500 kVA or 2,500 kVA and above (e.g. 110\/35 kV, 220\/110 kV).<\/p>\n<h3>How long does a distribution transformer last?<\/h3>\n<p>The design life of oil-immersed devices can be between 25 and 35 years assuming they have been designed, protected, and maintained properly. The insulation durability is halved for approximately each 8 K over temperature above the winding rise threshold of 65 K. Practical fleet experience indicates that if devices operate at no more than 70% average load and are subjected to oil check every 2-3 years, they will achieve design life, and overloaded units in cities may die after 10-15 years.<\/p>\n<h3>Why are distribution transformer losses so important?<\/h3>\n<p>Since they operate continuously. An S7 generator with a rating of 630 kVA has annual iron losses of approximately 2,000 to 2,500 kWh compared to an amorphous-core generator, which costs $200 to $300 a year at the rate of $0.10 per kilowatt-hour over the span of 25 years and more. For thousands of generators, the result of this discrepancy is either meeting or failing to meet the target.<\/p>\n<h3>Should I buy oil-immersed or dry-type transformers?<\/h3>\n<p>Oil-filled equipment costs around 30 to 50 percent less compared to similar dry-type equipment, produces less noise, and proves more efficient for outdoor application. Dry-type or resin-filled equipment finds application in areas where the risk of fire is a concern such as hospitals, tunnels, to comply with the regulations, or indoor placements. If the installation site has no constraints with regard to fire and is outdoors, oil-filled equipment tends to be the rational choice from the economic perspective.<\/p>\n<h3>How much does a distribution transformer cost in 2026?<\/h3>\n<p>For oil-immersed units FOB from China: single-phase pole types run <strong>$350\u2013$1,500<\/strong> (5\u2013167 kVA); three-phase pole\/pad types run <strong>$1,500\u2013$12,000<\/strong> (15\u2013500 kVA); larger pad-mounted and substation units run <strong>$8,000\u2013$25,000<\/strong> (630\u20132,500 kVA). Dry-type units cost 30\u201350% more. Add 30\u201350% for landing, installation, and commissioning.<\/p>\n<h2 id=\"references\">Riferimenti<\/h2>\n<ul>\n<li><a href=\"https:\/\/www.iec.ch\/\" rel=\"nofollow noopener\" target=\"_blank\">IEC<\/a> \u2014 Publisher of IEC 60076, the core standard for distribution transformers.<\/li>\n<li><a href=\"https:\/\/www.iea.org\/\" rel=\"nofollow noopener\" target=\"_blank\">International Energy Agency (IEA)<\/a> \u2014 Data and analysis on distribution losses and transformer efficiency.<\/li>\n<li><a href=\"https:\/\/www.ieee.org\/\" rel=\"nofollow noopener\" target=\"_blank\">IEEE<\/a> \u2014 Source of IEEE C57.12 and C57.12.20 standards for the Americas.<\/li>\n<li><a href=\"https:\/\/www.nema.org\/\" rel=\"nofollow noopener\" target=\"_blank\">NEMA<\/a> \u2014 TP-1 efficiency standard for distribution transformers in North America.<\/li>\n<li><a href=\"https:\/\/www.energy.gov\/\" rel=\"nofollow noopener\" target=\"_blank\">Dipartimento dell'Energia degli Stati Uniti<\/a> \u2014 Distribution transformer efficiency regulations and market data.<\/li>\n<li><a href=\"https:\/\/ec.europa.eu\/\" rel=\"nofollow noopener\" target=\"_blank\">European Commission<\/a> \u2014 Ecodesign regulation 548\/2014 and 2019\/1783 for transformers.<\/li>\n<li><a href=\"https:\/\/subian-electric.com\/it\/\">Jiangsu Subian Energia Elettrica<\/a> \u2014 Manufacturer of oil-immersed and dry-type distribution transformers.<\/li>\n<\/ul>\n<h2 id=\"conclusion\">Conclusione<\/h2>\n<ul>\n<li>The distribution transformers play a vital role in the electrical system&#8217;s overall functioning, and they also make final voltage changes while also doing earthing. As a result, they have become an active part of the smart electricity systems with solar energy, energy storage, and electric vehicle charging systems.\n<p>The loss rating, vector group, and the range of tap should be noted as their cost and performance depend upon them.<\/p>\n<p>The most cost-effective transformer available should be purchased since one recovered the costs of the lost power in 3-6 years after the purchase of the transformer.<\/p>\n<p>Budget $400-$25,000, depending on its type and ratings, plus the cost of installation and landing ranging from 30-50%.<\/li>\n<li>Whether you choose ABB, Siemens, Schneider, or a cost-competitive manufacturer like <strong>Jiangsu Subian Energia Elettrica<\/strong>, insist on IEC 60076 test documentation and loss guarantees in writing.<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>A young engineer in charge of planning in a public utility spends her time preparing for next year&#8217;s budget. This involves not merely connecting the new solar park of 40 MW capacity and getting new power connections to 3,000 households built on the perimeter of the city but also achieving the new regulatory requirement to [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":10700,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[77],"tags":[],"class_list":["post-10699","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/subian-electric.com\/it\/wp-json\/wp\/v2\/posts\/10699","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/subian-electric.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/subian-electric.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/subian-electric.com\/it\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/subian-electric.com\/it\/wp-json\/wp\/v2\/comments?post=10699"}],"version-history":[{"count":3,"href":"https:\/\/subian-electric.com\/it\/wp-json\/wp\/v2\/posts\/10699\/revisions"}],"predecessor-version":[{"id":11111,"href":"https:\/\/subian-electric.com\/it\/wp-json\/wp\/v2\/posts\/10699\/revisions\/11111"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/subian-electric.com\/it\/wp-json\/wp\/v2\/media\/10700"}],"wp:attachment":[{"href":"https:\/\/subian-electric.com\/it\/wp-json\/wp\/v2\/media?parent=10699"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/subian-electric.com\/it\/wp-json\/wp\/v2\/categories?post=10699"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/subian-electric.com\/it\/wp-json\/wp\/v2\/tags?post=10699"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}