{"id":363,"date":"2026-08-22T02:34:07","date_gmt":"2026-08-21T18:34:07","guid":{"rendered":"https:\/\/q8bbzjnpm5.wpdns.site\/?p=363"},"modified":"2026-08-29T23:43:42","modified_gmt":"2026-08-29T15:43:42","slug":"classification-of-power-transformers-and-their-unique-roles-in-the-power-grid","status":"publish","type":"post","link":"https:\/\/subian-electric.com\/ja\/news\/classification-of-power-transformers-and-their-unique-roles-in-the-power-grid\/","title":{"rendered":"\u96fb\u529b\u5909\u5727\u5668\u306e\u5206\u985e\u3068\u96fb\u529b\u30b0\u30ea\u30c3\u30c9\u306b\u304a\u3051\u308b\u305d\u306e\u72ec\u81ea\u306e\u5f79\u5272"},"content":{"rendered":"<p>\u30b5\u30d6\u30b9\u30c6\u30fc\u30b7\u30e7\u30f3\u30a8\u30f3\u30b8\u30cb\u30a2\u304c132 kV\u9001\u96fb\u306e\u30a2\u30c3\u30d7\u30b0\u30ec\u30fc\u30c9\u306b\u95a2\u3059\u308b\u5165\u672d\u66f8\u985e\u3092\u78ba\u8a8d\u3059\u308b\u969b\u3001\u901a\u5e38\u6700\u521d\u306b\u30ec\u30d3\u30e5\u30fc\u3055\u308c\u308b\u4ed5\u69d8\u66f8\u306e\u4e00\u3064\u306f\u3001\u96fb\u529b\u5909\u5727\u5668\u306e\u5206\u985e\u8868\u3067\u3059\u3002\u306a\u305c\u306a\u3089\u3001\u8aa4\u3063\u305f\u9078\u629e\u306f\u6570\u5341\u4e07\u306e\u30b3\u30b9\u30c8\u3092\u5f15\u304d\u8d77\u3053\u3057\u3001\u904b\u8ee2\u958b\u59cb\u30d7\u30ed\u30bb\u30b9\u306b\u6570\u30f6\u6708\u306e\u9045\u5ef6\u3092\u3082\u305f\u3089\u3059\u53ef\u80fd\u6027\u304c\u3042\u308b\u304b\u3089\u3067\u3059\u3002\u96fb\u529b\u5909\u5727\u5668\u306e\u5404\u30bf\u30a4\u30d7\u306e\u5206\u985e\u306f\u3001\u96fb\u5727\u3001\u8ca0\u8377\u3001\u4fe1\u983c\u6027\u306b\u95a2\u3059\u308b\u7279\u5b9a\u306e\u554f\u984c\u306b\u5bfe\u51e6\u3059\u308b\u305f\u3081\u306b\u4f5c\u6210\u3055\u308c\u3066\u304a\u308a\u300110 MVA\u306e\u914d\u96fb\u30e6\u30cb\u30c3\u30c8\u304c\u5de5\u5834\u306e\u30d6\u30ed\u30c3\u30af\u5185\u3067\u7a3c\u50cd\u3057\u3066\u3044\u308b\u5834\u5408\u3067\u3082\u3001400 MVA\u306e\u767a\u96fb\u6a5f\u6607\u5727\u5909\u5727\u5668\u304c\u77f3\u70ad\u706b\u529b\u767a\u96fb\u6240\u306b\u8a2d\u7f6e\u3055\u308c\u3066\u3044\u308b\u5834\u5408\u3067\u3082\u540c\u69d8\u3067\u3059\u3002.<\/p>\n<p>\u63d0\u4f9b\u3055\u308c\u305f\u8a18\u4e8b\u306f\u3001\u96fb\u529b\u5909\u5727\u5668\u3092\u5206\u985e\u3059\u308b\u305f\u3081\u306e\u3059\u3079\u3066\u306e\u53ef\u80fd\u306a\u65b9\u6cd5\u3092\u8aac\u660e\u3057\u3066\u3044\u307e\u3059\u3002\u3053\u308c\u306b\u306f\u3001\u96fb\u529b\u6a5f\u80fd\u306b\u3088\u308b\u5206\u985e\u3001\u96fb\u5727\u30ec\u30d9\u30eb\u306b\u3088\u308b\u5206\u985e\u3001\u5dfb\u7dda\u306e\u69cb\u6210\u306b\u3088\u308b\u5206\u985e\u3001\u51b7\u5374\u65b9\u5f0f\u306b\u3088\u308b\u5206\u985e\u3001\u7d76\u7e01\u6750\u6599\u306e\u7a2e\u985e\u306b\u3088\u308b\u5206\u985e\u306a\u3069\u304c\u542b\u307e\u308c\u307e\u3059\u3002.<\/p>\n<blockquote><p>\u7c21\u5358\u306b\u8a00\u3048\u3070\u3001\u96fb\u529b\u5909\u5727\u5668\u306f\u3001\u6607\u5727\u5909\u5727\u5668\u3001\u964d\u5727\u5909\u5727\u5668\u3001\u914d\u96fb\u5909\u5727\u5668\u3001\u7d76\u7e01\u5909\u5727\u5668\u3001\u81ea\u52d5\u5909\u5727\u5668\u306a\u3069\u306e\u6a5f\u80fd\u306b\u57fa\u3065\u3044\u3066\u5206\u985e\u3067\u304d\u307e\u3059\u3002\u307e\u305f\u3001\u767a\u96fb\u6a5f\u5909\u5727\u5668\u3001\u9001\u96fb\u5909\u5727\u5668\u3001\u914d\u96fb\u5909\u5727\u5668\u306a\u3069\u306e\u96fb\u5727\u30af\u30e9\u30b9\u306b\u57fa\u3065\u3044\u3066\u3001\u5358\u76f8\u5909\u5727\u5668\u3068\u4e09\u76f8\u5909\u5727\u5668\u3001\u4e8c\u5dfb\u7dda\u5909\u5727\u5668\u3068\u4e09\u5dfb\u7dda\u5909\u5727\u5668\u306a\u3069\u306e\u5dfb\u7dda\u69cb\u6210\u306b\u57fa\u3065\u3044\u3066\u3001ONAN\u5909\u5727\u5668\u3001ONAF\u5909\u5727\u5668\u3001OFAF\u5909\u5727\u5668\u3001ODAF\u5909\u5727\u5668\u306a\u3069\u306e\u51b7\u5374\u65b9\u5f0f\u306b\u57fa\u3065\u3044\u3066\u3001\u6cb9\u6d78\u5909\u5727\u5668\u3068\u4e7e\u5f0f\u5909\u5727\u5668\u306a\u3069\u306e\u7d76\u7e01\u65b9\u5f0f\u306b\u57fa\u3065\u3044\u3066\u5206\u985e\u3067\u304d\u307e\u3059\u3002.<\/p><\/blockquote>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-364\" src=\"https:\/\/subian-electric.com\/wp-content\/uploads\/2026\/08\/Classification-Of-Power-Transformers-And-Their-Unique-Roles-In-The-Power-Grid.webp\" alt=\"Classification Of Power Transformers And Their Unique Roles In The Power Grid\" width=\"1448\" height=\"1086\" \/><\/p>\n<hr \/>\n<h2 id=\"definition\">\u96fb\u529b\u5909\u5727\u5668\u3068\u306f\u4f55\u3067\u3059\u304b\uff1f\uff08\u5b9a\u7fa9\u3068\u30b3\u30a2\u6a5f\u80fd\uff09<\/h2>\n<p>\u96fb\u529b\u5909\u5727\u5668\u306f\u3001\u96fb\u78c1\u8a98\u5c0e\u306e\u30d7\u30ed\u30bb\u30b9\u3092\u901a\u3058\u3066\u30012\u3064\u4ee5\u4e0a\u306e\u56de\u8def\u3092\u4ecb\u3057\u3066\u96fb\u529b\u3092\u4f1d\u9001\u3059\u308b\u9759\u7684\u306a\u96fb\u78c1\u6a5f\u5668\u3067\u3042\u308a\u3001\u5468\u6ce2\u6570\u3068\u898b\u304b\u3051\u306e\u96fb\u529b\u3092\u4e00\u5b9a\u306b\u4fdd\u3061\u306a\u304c\u3089\u96fb\u5727\u30ec\u30d9\u30eb\u3092\u5909\u66f4\u3057\u307e\u3059\uff08\u640d\u5931\u3092\u542b\u3080\uff09\u3002\u914d\u96fb\u5909\u5727\u5668\u306f\u4e3b\u306b\u6d88\u8cbb\u306e\u305f\u3081\u306e\u6700\u7d42\u96fb\u5727\u964d\u4e0b\u3092\u884c\u3044\u307e\u3059\u304c\u3001\u96fb\u529b\u5909\u5727\u5668\u306f\u3001200 kVA\u3092\u8d85\u3048\u308b\u5b9a\u683c\u3092\u6301\u3064\u30b5\u30d6\u30b9\u30c6\u30fc\u30b7\u30e7\u30f3\u3001\u767a\u96fb\u6240\u3001\u5927\u898f\u6a21\u7523\u696d\u306b\u898b\u3089\u308c\u30013.3 kV\u304b\u30891,150 kV\u30af\u30e9\u30b9\u306e\u96fb\u5727\u3092\u51e6\u7406\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002.<\/p>\n<p>\u96fb\u529b\u5909\u5727\u5668\u306f\u3001\u5b9a\u683c\u898b\u304b\u3051\u96fb\u529b\uff08kVA\u307e\u305f\u306fMVA\uff09\u3001\u5b9a\u683c\u96fb\u5727\u6bd4\u3001\u77ed\u7d61\u6642\u306e\u30a4\u30f3\u30d4\u30fc\u30c0\u30f3\u30b9\u306e3\u3064\u306e\u5024\u3067\u7279\u5fb4\u4ed8\u3051\u3089\u308c\u307e\u3059\uff08\u3053\u308c\u306f\u56fd\u969b\u898f\u683cIEC 60076-5\u306b\u5f93\u3063\u3066\u901a\u5e385%\u304b\u308915%\u306e\u9593\u3067\u3059\uff09\u3002\u6700\u5927\u904b\u8ee2\u5bb9\u91cf\u3067\u306e\u5909\u5727\u5668\u306e\u52b9\u7387\u306f\u901a\u5e3898.%\u304b\u308999.7%\u306e\u9593\u3067\u3059\u3002\u3053\u308c\u304c\u3001\u96fb\u529b\u4f1a\u793e\u304c\u4f4e\u640d\u5931\u306e\u30a2\u30e2\u30eb\u30d5\u30a1\u30b9\u30b3\u30a2\u8a2d\u8a08\u3084\u9ad8\u54c1\u8cea\u306e\u914d\u5411\u30b7\u30ea\u30b3\u30f3\u92fc\u306b\u591a\u984d\u306e\u6295\u8cc7\u3092\u3059\u308b\u7406\u7531\u3067\u3059\u3002.<\/p>\n<h2 id=\"how-it-works\">\u96fb\u529b\u5909\u5727\u5668\u306e\u52d5\u4f5c\u539f\u7406\uff1a\u96fb\u78c1\u539f\u7406<\/h2>\n<p>\u57fa\u672c\u7684\u306a\u52d5\u4f5c\u539f\u7406\u306f\u3001\u30d5\u30a1\u30e9\u30c7\u30fc\u306e\u96fb\u78c1\u8a98\u5c0e\u306e\u6cd5\u5247\u306b\u57fa\u3065\u3044\u3066\u3044\u307e\u3059\u3002\u4e00\u6b21\u5dfb\u7dda\u306e\u4ea4\u6d41\u306f\u3001\u30b7\u30ea\u30b3\u30f3\u92fc\u30b3\u30a2\u5185\u306b\u5909\u52d5\u3059\u308b\u78c1\u675f\u3092\u751f\u6210\u3057\u3001\u4e8c\u6b21\u5dfb\u7dda\u3068\u9023\u7d50\u3057\u3001\u5dfb\u6570\u306b\u6bd4\u4f8b\u3057\u305f\u8d77\u96fb\u529b\uff08emf\uff09\u3092\u8a98\u5c0e\u3057\u307e\u3059\u3002\u3053\u308c\u306f\u6b21\u306e\u53e4\u5178\u7684\u306a\u5f0f\u3067\u8868\u3055\u308c\u307e\u3059\uff1a<\/p>\n<p>Vprimary \/ Vsecondary = Nprimary \/ Nsecondary\uff08\u3053\u308c\u3092\u5dfb\u6570\u6bd4\u3068\u547c\u3073\u307e\u3059\uff09\u3001\u3057\u305f\u304c\u3063\u3066\u4ed6\u306e\u6761\u4ef6\u304c\u7406\u60f3\u7684\u3067\u3042\u308c\u3070\u3001Iprimary \u00d7 Vprimary \u2248 Isecondary \u00d7 Vsecondary \u3068\u306a\u308a\u307e\u3059\u3002.<\/p>\n<p>\u30b9\u30c6\u30c3\u30d7\u30a2\u30c3\u30d7\u30e2\u30fc\u30c9\u3067\u52d5\u4f5c\u3059\u308b\u5909\u5727\u5668\u306f\u3001\u4e8c\u6b21\u5dfb\u7dda\u306b\u4e00\u6b21\u3088\u308a\u3082\u591a\u304f\u306e\u5dfb\u6570\u304c\u3042\u308a\u307e\u3059\u3002\u30b9\u30c6\u30c3\u30d7\u30c0\u30a6\u30f3\u30e2\u30fc\u30c9\u3067\u52d5\u4f5c\u3059\u308b\u5909\u5727\u5668\u306f\u3001\u4e00\u6b21\u30b3\u30a4\u30eb\u306b\u3088\u308a\u591a\u304f\u306e\u5dfb\u6570\u304c\u3042\u308a\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u5b9f\u969b\u306e\u96fb\u529b\u5909\u5727\u5668\u306f\u3001\u9285\u640d\u5931\uff08\u9285\u7dda\u306eI\u00b2R\u640d\u5931\uff09\u3084\u9244\u640d\u5931\uff08\u30d2\u30b9\u30c6\u30ea\u30b7\u30b9\u3084\u6e26\u96fb\u6d41\u306b\u3088\u308b\uff09\u306b\u8d77\u56e0\u3059\u308b\u7d040.3%\u304b\u30892%\u306e\u640d\u5931\u3067\u52d5\u4f5c\u3057\u307e\u3059\u3002\u3057\u305f\u304c\u3063\u3066\u3001\u4efb\u610f\u306e\u5909\u5727\u5668\u306e\u6280\u8853\u7684\u7279\u6027\u306b\u306f\u3001\u52b9\u7387\u30ec\u30d9\u30eb\u304c50%\u300175%\u3001\u307e\u305f\u306f100%\u3067\u3042\u308b\u304b\u3069\u3046\u304b\u304c\u8a18\u8f09\u3055\u308c\u3066\u3044\u307e\u3059\u3002.<\/p>\n<h2 id=\"classification-by-function\">\u6a5f\u80fd\u306b\u3088\u308b\u5206\u985e\uff1a\u30b9\u30c6\u30c3\u30d7\u30a2\u30c3\u30d7\u3001\u30b9\u30c6\u30c3\u30d7\u30c0\u30a6\u30f3\u3001\u914d\u96fb\u3001\u81ea\u52d5<\/h2>\n<p>\u6a5f\u80fd\u306f\u3001\u30a8\u30cd\u30eb\u30ae\u30fc\u8ee2\u9001\u306b\u304a\u3051\u308b\u30e6\u30cb\u30c3\u30c8\u306e\u4f4d\u7f6e\u3092\u793a\u3059\u305f\u3081\u3001\u96fb\u529b\u5909\u5727\u5668\u3092\u5206\u985e\u3059\u308b\u6700\u3082\u5b9f\u7528\u7684\u306a\u624b\u6bb5\u3067\u3059\u3002\u4ee5\u4e0b\u306e\u8868\u306f\u3001\u30a8\u30f3\u30b8\u30cb\u30a2\u304c\u30b0\u30ea\u30c3\u30c9\u3067\u4e00\u822c\u7684\u306b\u4f7f\u7528\u3059\u308b4\u3064\u306e\u7570\u306a\u308b\u6a5f\u80fd\u30d5\u30a1\u30df\u30ea\u30fc\u306e\u5909\u5727\u5668\u3092\u8981\u7d04\u3057\u3066\u3044\u307e\u3059\u3002.<\/p>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"6\">\n<caption>\u96fb\u529b\u5909\u5727\u5668\u306e\u6a5f\u80fd\u7684\u5206\u985e<\/caption>\n<tbody>\n<tr>\n<th>\u6a5f\u80fd<\/th>\n<th>\u5178\u578b\u7684\u306a\u96fb\u5727\u5909\u5316<\/th>\n<th>\u5178\u578b\u7684\u306a\u5b9a\u683c<\/th>\n<th>\u3069\u3053\u3067\u898b\u3064\u3051\u308b\u304b<\/th>\n<\/tr>\n<tr>\n<td>\u767a\u96fb\u6a5f\u30b9\u30c6\u30c3\u30d7\u30a2\u30c3\u30d7\uff08GSU\uff09<\/td>\n<td>11\u201327 kV \u2192 110\u2013765 kV<\/td>\n<td>100\u20131,200 MVA<\/td>\n<td>\u767a\u96fb\u6240\u3001\u98a8\u529b\u304a\u3088\u3073\u592a\u967d\u5149\u767a\u96fb\u6240<\/td>\n<\/tr>\n<tr>\n<td>\u9001\u96fb\u30b9\u30c6\u30c3\u30d7\u30c0\u30a6\u30f3<\/td>\n<td>220\u2013765 kV \u2192 66\u2013132 kV<\/td>\n<td>50\u2013400 MVA<\/td>\n<td>\u9ad8\u5727\u5909\u96fb\u6240<\/td>\n<\/tr>\n<tr>\n<td>\u30b5\u30d6\u9001\u96fb \/ \u914d\u96fb<\/td>\n<td>33\u2013132 kV \u2192 6.6\u201335 kV<\/td>\n<td>1\u201320 MVA<\/td>\n<td>\u4e00\u6b21\u5909\u96fb\u6240\u3001\u7523\u696d\u7528\u30d5\u30a3\u30fc\u30c0\u30fc<\/td>\n<\/tr>\n<tr>\n<td>\u81ea\u52d5\u5909\u5727\u5668<\/td>\n<td>\u4f8b\uff1a220 kV \u2192 110 kV<\/td>\n<td>100\u20131,000 MVA<\/td>\n<td>\u30b0\u30ea\u30c3\u30c9\u30ec\u30d9\u30eb\u9593\u306e\u76f8\u4e92\u63a5\u7d9a<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>GSU\uff08\u767a\u96fb\u6a5f\u30b9\u30c6\u30c3\u30d7\u30a2\u30c3\u30d7\uff09\u5909\u5727\u5668\u306f\u3001\u767a\u96fb\u6240\u306e\u30b9\u30da\u30af\u30c8\u30eb\u306e\u767a\u96fb\u6a5f\u7aef\u306b\u4f4d\u7f6e\u3057\u3001\u767a\u96fb\u6240\u5185\u3067\u6700\u3082\u4fa1\u5024\u306e\u3042\u308b\u6a5f\u5668\u3067\u3059\u3002\u5b9f\u969b\u3001600 MVA\u306eGSU\u5909\u5727\u5668\u306f\u3001\u706b\u529b\u767a\u96fb\u6240\u3067$800,000\u304b\u3089$2.5\u767e\u4e07\u306e\u9593\u3067\u4fa1\u683c\u304c\u8a2d\u5b9a\u3055\u308c\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u81ea\u52d5\u5909\u5727\u5668\u306f\u3001\u5f93\u6765\u306e\u4e8c\u6b21\u5dfb\u7dda\u5909\u5727\u5668\u3088\u308a\u3082\u5c0f\u578b\u3067\u5b89\u4fa1\u3067\u3042\u308b\u50be\u5411\u304c\u3042\u308a\u307e\u3059\u304c\u3001\u4e00\u90e8\u306e\u5dfb\u7dda\u304c\u5171\u6709\u3055\u308c\u3066\u3044\u308b\u305f\u3081\u53ef\u80fd\u3067\u3059\u3002\u3057\u305f\u304c\u3063\u3066\u3001\u76f8\u4e92\u63a5\u7d9a\u306e\u30e6\u30fc\u30c6\u30a3\u30ea\u30c6\u30a3\u4f1a\u793e\u306f\u3001\u7279\u306b220\/110 kV\u3084400\/220 kV\u306e\u3088\u3046\u306a\u4f4e\u6bd4\u7387\u96fb\u5727\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306b\u81ea\u52d5\u5909\u5727\u5668\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3092\u9078\u629e\u3057\u307e\u3059\u3002.<\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-365\" src=\"https:\/\/subian-electric.com\/wp-content\/uploads\/2026\/08\/Classification-by-Function-Step-Up-Step-Down-Distribution-Auto.webp\" alt=\"Classification by Function Step-Up, Step-Down, Distribution, Auto\" width=\"1448\" height=\"1086\" \/><\/p>\n<h2 id=\"classification-by-voltage\">\u30b0\u30ea\u30c3\u30c9\u306b\u304a\u3051\u308b\u96fb\u5727\u30ec\u30d9\u30eb\u306b\u3088\u308b\u5206\u985e<\/h2>\n<p>\u96fb\u5727\u30af\u30e9\u30b9\u306f\u3001\u7d76\u7e01\u8a2d\u8a08\u3084\u30a8\u30cd\u30eb\u30ae\u30fc\u6a5f\u5668\u306e\u8a2d\u8a08\u306b\u5f71\u97ff\u3092\u4e0e\u3048\u3001\u7d76\u7e01\u6280\u8853\u3092\u542b\u307f\u307e\u3059\u3002\u30a8\u30cd\u30eb\u30ae\u30fc\u6a5f\u5668\u306e\u4fa1\u683c\u306f\u3001\u96fb\u5727\u30af\u30e9\u30b9\u306b\u3088\u3063\u3066\u5f71\u97ff\u3092\u53d7\u3051\u307e\u3059\u3002IEC 60076-1\u304a\u3088\u3073IEEE C57.12.00\u306e\u4e21\u65b9\u306e\u898f\u683c\u304c\u7d76\u7e01\u6280\u8853\u3092\u6c7a\u5b9a\u3057\u307e\u3059\u3002.<\/p>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"6\">\n<caption>\u96fb\u529b\u5909\u5727\u5668\u306e\u96fb\u5727\u30af\u30e9\u30b9<\/caption>\n<tbody>\n<tr>\n<th>\u30b0\u30ea\u30c3\u30c9\u30ec\u30d9\u30eb<\/th>\n<th>\u5b9a\u683c\u96fb\u5727<\/th>\n<th>BIL\uff08\u96f7\u30a4\u30f3\u30d1\u30eb\u30b9\u8010\u5727\uff09<\/th>\n<th>\u5178\u578b\u7684\u306a\u5f79\u5272<\/th>\n<\/tr>\n<tr>\n<td>\u767a\u96fb\u6a5f\u96fb\u5727<\/td>\n<td>3\u201333 kV<\/td>\n<td>40\u2013200 kV<\/td>\n<td>GSU\u5165\u529b\u5074\u3001\u88dc\u52a9\u4f9b\u7d66<\/td>\n<\/tr>\n<tr>\n<td>\u4e2d\u5727\uff08MV\uff09<\/td>\n<td>6\u201335 kV<\/td>\n<td>75\u2013250 kV<\/td>\n<td>\u914d\u96fb\u5909\u96fb\u6240\u3001\u7523\u696d\u7528<\/td>\n<\/tr>\n<tr>\n<td>\u9ad8\u5727\uff08HV\uff09<\/td>\n<td>66\u2013220 kV<\/td>\n<td>325\u2013950 kV<\/td>\n<td>\u5730\u57df\u9001\u96fb<\/td>\n<\/tr>\n<tr>\n<td>\u8d85\u9ad8\u5727 (EHV)<\/td>\n<td>330\u2013765 kV<\/td>\n<td>1,175\u20131,950 kV<\/td>\n<td>\u56fd\u5bb6\u9001\u96fb\u30d0\u30c3\u30af\u30dc\u30fc\u30f3<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u4e16\u754c\u4e2d\u306b\u8a2d\u7f6e\u3055\u308c\u3066\u3044\u308b\u3059\u3079\u3066\u306e\u5909\u5727\u5668\u306e\u7d0470%\u306f\u914d\u96fb\u6bb5\u968e\u306b\u3042\u308a\u307e\u3059\u304c\u3001\u30b3\u30b9\u30c8\u306e\u7d0430%\u3057\u304b\u5360\u3081\u3066\u3044\u307e\u305b\u3093\u3002500 kV\u306e\u96fb\u6c17\u30b7\u30b9\u30c6\u30e0\u30681,550\u306eBIL\u5024\u3092\u6301\u3064\u9ad8\u96fb\u5727\u30e6\u30cb\u30c3\u30c8\u306f\u3001\u539a\u3044\u7d76\u7e01\u3001\u5e83\u3044\u4e2d\u6027\u30be\u30fc\u30f3\u3001\u304a\u3088\u3073\u7279\u5225\u306a\u8a66\u9a13\u624b\u9806\uff08IEC 60076-3\u306b\u5f93\u3063\u305f\u90e8\u5206\u653e\u96fb\u8a66\u9a13\u304a\u3088\u3073\u30a4\u30f3\u30d1\u30eb\u30b9\u30c6\u30b9\u30c8\uff09\u306e\u8981\u4ef6\u3092\u6e80\u305f\u3057\u3066\u3044\u308b\u305f\u3081\u3001\u5f37\u529b\u306a\u5909\u5727\u5668\u306e\u8a2d\u7f6e\u306b\u306f$1.5\u2013$3\u767e\u4e07\u306e\u652f\u51fa\u304c\u5fc5\u8981\u306b\u306a\u308b\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002.<\/p>\n<h2 id=\"classification-by-phase-winding\">\u76f8\u3068\u5dfb\u7dda\u69cb\u6210\u306b\u3088\u308b\u5206\u985e<\/h2>\n<p>\u96fb\u529b\u5909\u5727\u5668\u306f\u3001\u305d\u306e\u69cb\u9020\u306b\u57fa\u3065\u3044\u3066\u5358\u76f8\u307e\u305f\u306f\u4e09\u76f8\u5909\u5727\u5668\u306b\u5206\u985e\u3067\u304d\u307e\u3059\u3002\u3053\u308c\u306f\u3001\u30bf\u30a4\u30d7\u3060\u3051\u3067\u306a\u304f\u3001\u5dfb\u7dda\u306e\u6570\u3001\u3059\u306a\u308f\u3061\u4e8c\u5dfb\u7dda\u5909\u5727\u5668\u3001\u4e09\u5dfb\u7dda\u5909\u5727\u5668\u3001\u307e\u305f\u306f\u81ea\u52d5\u69cb\u6210\u5909\u5727\u5668\u3068\u3057\u3066\u3082\u5206\u985e\u3055\u308c\u307e\u3059\u3002\u5358\u76f8\u5909\u5727\u5668\u306f\u3001\u30b3\u30b9\u30c8\u304c\u5b89\u304f\u8f38\u9001\u304c\u5bb9\u6613\u3067\u3042\u308b\u305f\u3081\u5e83\u304f\u53d7\u3051\u5165\u308c\u3089\u308c\u3066\u304a\u308a\u3001\u7279\u306b\u6700\u9ad8\u306eEHV\u5b9a\u683c\uff08\u4f8b\uff1a500 kV\u3067\u52d5\u4f5c\u3059\u308b\u4e09\u3064\u306e\u5358\u76f8\u5909\u5727\u5668\u304b\u3089\u306a\u308b3\u00d7333 MVA\u30d0\u30f3\u30af\u306e\u5f62\u6210\uff09\u306b\u95a2\u3057\u3066\u306f\u7279\u306b\u6709\u7528\u3067\u3059\u3002\u4e00\u65b9\u3001300 MVA\u4ee5\u4e0b\u306e\u5909\u52d5\u306b\u5bfe\u3057\u3066\u306f\u3001\u640d\u5931\u3001\u30b3\u30b9\u30c8\u52b9\u7387\u306e\u826f\u3044\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u3001\u304a\u3088\u3073\u52b9\u7387\u306e\u9762\u3067\u5358\u76f8\u30d0\u30ea\u30a2\u30f3\u30c8\u3088\u308a\u3082\u512a\u4f4d\u6027\u304c\u3042\u308b\u305f\u3081\u3001\u4e09\u76f8\u5909\u5727\u5668\u304c\u3088\u308a\u9069\u3057\u3066\u3044\u307e\u3059\u3002.<\/p>\n<p>\u4e09\u5dfb\u7dda\u5909\u5727\u5668\u306f\u4e09\u6b21\u5dfb\u7dda\u3092\u5099\u3048\u3066\u304a\u308a\u3001\u6a19\u6e96\u7684\u306a\u96fb\u6c17\u8ca0\u8377\u3060\u3051\u3067\u306a\u304f\u3001\u30cf\u30fc\u30e2\u30cb\u30c3\u30af\u30d5\u30a3\u30eb\u30bf\u30fc\u3084\u7b2c\u4e09\u306e\u96fb\u5727\uff08\u4f8b\uff1a220\/110\/35 kV\uff09\u3092\u5c0e\u51fa\u3059\u308b\u305f\u3081\u306b\u3082\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u30d9\u30af\u30c8\u30eb\u30b0\u30eb\u30fc\u30d7\u306f\u3001Dyn11\u3001YNyn0\u3001YNd11\u306a\u3069\u306e\u7279\u5225\u306a\u6307\u5b9a\u3092\u7528\u3044\u3066\u5b9a\u7fa9\u3067\u304d\u3001\u5909\u5727\u5668\u306e\u69cb\u6210\u3068\u96fb\u5727\u306e\u30dd\u30a4\u30f3\u30c8\u3092\u793a\u3057\u307e\u3059\u3002.<\/p>\n<h2 id=\"classification-by-cooling\">\u51b7\u5374\u65b9\u5f0f\u306b\u3088\u308b\u5206\u985e (IEC 60076-2)<\/h2>\n<p>\u51b7\u5374\u30b7\u30b9\u30c6\u30e0\u306f\u3001\u5909\u5727\u5668\u304c\u5b89\u5168\u306b\u51e6\u7406\u3067\u304d\u308b\u6700\u5927\u96fb\u529b\u91cf\u3092\u6c7a\u5b9a\u3057\u307e\u3059\u3002IEC 60076-2\u306b\u5f93\u3063\u3066\u4f7f\u7528\u3055\u308c\u308b\u7565\u8a9e\u306f\u3001\u51b7\u5374\u5a92\u4f53\u306e\u7a2e\u985e\u3068\u305d\u306e\u5faa\u74b0\u65b9\u6cd5\u3092\u6307\u3057\u307e\u3059\u3002.<\/p>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"6\">\n<caption>\u51b7\u5374\u65b9\u5f0f\u306e\u5206\u985e (IEC 60076-2)<\/caption>\n<tbody>\n<tr>\n<th>\u51b7\u5374\u30b3\u30fc\u30c9<\/th>\n<th>\u610f\u5473<\/th>\n<th>\u5178\u578b\u7684\u306a\u5b9a\u683c<\/th>\n<th>\u8ca0\u8377\u80fd\u529b vs. ONAN<\/th>\n<\/tr>\n<tr>\n<td>ONAN<\/td>\n<td>\u81ea\u7136\u6cb9\u3001\u81ea\u7136\u7a7a\u6c17<\/td>\n<td>50 kVA\u201360 MVA<\/td>\n<td>\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3 (100%)<\/td>\n<\/tr>\n<tr>\n<td>ONAF<\/td>\n<td>\u81ea\u7136\u6cb9\u3001\u5f37\u5236\u7a7a\u6c17\uff08\u30d5\u30a1\u30f3\uff09<\/td>\n<td>1\u2013150 MVA<\/td>\n<td>\u2248120\u2013135%<\/td>\n<\/tr>\n<tr>\n<td>OFAF<\/td>\n<td>\u5f37\u5236\u6cb9\u3001\u5f37\u5236\u7a7a\u6c17<\/td>\n<td>10\u2013300 MVA<\/td>\n<td>\u2248140\u2013160%<\/td>\n<\/tr>\n<tr>\n<td>ODAF<\/td>\n<td>\u6307\u5411\u6cb9\u3001\u5f37\u5236\u7a7a\u6c17<\/td>\n<td>100\u20131,200 MVA<\/td>\n<td>\u2248150\u2013170%<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>ONAN\u304a\u3088\u3073ONAF\u306e\u4e8c\u3064\u306e\u51b7\u5374\u30e2\u30fc\u30c9\u3067\u52d5\u4f5c\u3059\u308b\u3088\u3046\u306b\u8a2d\u8a08\u3055\u308c\u305f\u5909\u5727\u5668\u306f\u3001\u96fb\u529b\u4f1a\u793e\u304c\u901a\u5e38\u306e\u72b6\u6cc1\u4e0b\u3067\u81ea\u7136\u51b7\u5374\u30e2\u30fc\u30c9\u3067\u904b\u8ee2\u3057\u3001\u7a81\u7136\u306e\u904e\u8ca0\u8377\u6642\u306b\u30d5\u30a1\u30f3\u3092\u4f7f\u7528\u3067\u304d\u308b\u3053\u3068\u3092\u610f\u5473\u3057\u307e\u3059\u300240 MVA\u306e\u5bb9\u91cf\u3092\u6301\u3061\u3001\u300c40\/56 MVA ONAN\/ONAF\u300d\u3068\u3057\u3066\u305d\u306e\u6bd4\u7387\u3092\u793a\u3059\u5909\u5727\u5668\u304c\u5b9f\u7528\u7684\u306a\u4f8b\u3067\u3059\u3002\u30d5\u30a1\u30f3\u3084\u6cb9\u30dd\u30f3\u30d7\u306a\u3069\u306e\u5fc5\u8981\u306a\u88c5\u7f6e\u30b3\u30f3\u30dd\u30fc\u30cd\u30f3\u30c8\u306f\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u304c\u7c21\u5358\u3067\u306f\u306a\u3044\u305f\u3081\u3001\u5c0f\u898f\u6a21\u306a\u5909\u96fb\u6240\u306fONAN\u8a2d\u8a08\u306e\u307f\u3092\u597d\u307f\u307e\u3059\u3002.<\/p>\n<h2 id=\"classification-by-insulation\">\u6cb9\u6d78\u578b vs. \u4e7e\u5f0f\u96fb\u529b\u5909\u5727\u5668<\/h2>\n<p>\u7d76\u7e01\u5a92\u4f53\u306f\u3001\u5e02\u5834\u3092\u4fa1\u683c\u3001\u5b89\u5168\u6027\u3001\u4f7f\u7528\u306e\u9055\u3044\u306b\u57fa\u3065\u3044\u3066\u4e8c\u3064\u306e\u7570\u306a\u308b\u30ab\u30c6\u30b4\u30ea\u306b\u5206\u3051\u307e\u3059\u3002.<\/p>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"6\">\n<caption>\u6cb9\u6d78\u578b vs. \u4e7e\u5f0f\u5909\u5727\u5668<\/caption>\n<tbody>\n<tr>\n<th>\u30d1\u30e9\u30e1\u30fc\u30bf<\/th>\n<th>\u6cb9\u6d78\u578b<\/th>\n<th>\u4e7e\u5f0f\u578b\uff08\u30ad\u30e3\u30b9\u30c8\u30ec\u30b8\u30f3 \/ VPI\uff09<\/th>\n<\/tr>\n<tr>\n<td>\u7d76\u7e01\u5a92\u4f53<\/td>\n<td>\u30df\u30cd\u30e9\u30eb\u30aa\u30a4\u30eb\u307e\u305f\u306f\u30a8\u30b9\u30c6\u30eb<\/td>\n<td>\u30a8\u30dd\u30ad\u30b7\u6a39\u8102 \/ \u7a7a\u6c17<\/td>\n<\/tr>\n<tr>\n<td>\u4e00\u822c\u7684\u306a\u5b9a\u683c<\/td>\n<td>50 kVA\u20131,200 MVA<\/td>\n<td>100 VA\u201340 MVA<\/td>\n<\/tr>\n<tr>\n<td>\u4fa1\u683c (1 MVA \u30af\u30e9\u30b9)<\/td>\n<td>$18,000\u2013$45,000<\/td>\n<td>$28,000\u2013$70,000<\/td>\n<\/tr>\n<tr>\n<td>\u706b\u707d \/ \u74b0\u5883\u30ea\u30b9\u30af<\/td>\n<td>\u9ad8\u3044 (\u6cb9\u306e containment \u304c\u5fc5\u8981)<\/td>\n<td>\u4f4e\u3044\u3001\u96e3\u71c3\u6027<\/td>\n<\/tr>\n<tr>\n<td>\u6700\u9069\u306a\u5834\u6240<\/td>\n<td>\u5c4b\u5916\u5909\u96fb\u6240<\/td>\n<td>\u5c4b\u5185\u3001\u9ad8\u5c64\u3001\u30aa\u30d5\u30b7\u30e7\u30a2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u6cb9\u306e\u52b9\u7387\u7684\u306a\u8a98\u96fb\u7279\u6027\u306b\u3088\u308a\u3001\u30bc\u30ed\u304b\u30892 MVA\u306e\u7bc4\u56f2\u3067\u306f\u6cb9\u6d78\u5f0f\u5909\u5727\u5668\u304c\u512a\u4f4d\u3067\u3059\u3002\u4e7e\u5f0f\u5909\u5727\u5668\u306f\u3001\u30aa\u30d5\u30a3\u30b9\u30d3\u30eb\u3001\u75c5\u9662\u3001\u30aa\u30d5\u30b7\u30e7\u30a2\u306e\u77f3\u6cb9\u6398\u524a\u88c5\u7f6e\u3084\u30d7\u30e9\u30c3\u30c8\u30d5\u30a9\u30fc\u30e0\u306a\u3069\u3001\u706b\u707d\u306e\u5371\u967a\u6027\u304b\u3089\u6cb9\u6d78\u5f0f\u5909\u5727\u5668\u306e\u4f7f\u7528\u3092\u7981\u6b62\u3059\u308b\u6cd5\u5f8b\uff08NFPA 70\u306a\u3069\uff09\u304c\u3042\u308b\u5834\u6240\u3067\u3088\u308a\u826f\u3044\u6027\u80fd\u3092\u767a\u63ee\u3057\u307e\u3059\u3002\u30ad\u30e3\u30b9\u30c8\u6a39\u8102\u5909\u5727\u5668\u306f\u3001\u6bd4\u8f03\u53ef\u80fd\u306a\u6cb9\u30e2\u30c7\u30eb\u3088\u308a\u3082\u901a\u5e3840%-60%\u9ad8\u4fa1\u3067\u3059\u304c\u3001\u6cb9\u8caf\u7559\u30d4\u30c3\u30c8\u3084\u6d88\u706b\u30b7\u30b9\u30c6\u30e0\u3092\u5fc5\u8981\u3068\u3057\u307e\u305b\u3093\u3002.<\/p>\n<h2 id=\"specifications\">\u4e00\u822c\u7684\u306a\u5909\u5727\u5668\u30af\u30e9\u30b9\u306e\u4e3b\u8981\u4ed5\u69d8\u8868<\/h2>\n<p>\u5909\u5727\u5668\u30e2\u30c7\u30eb\u9593\u3067\u516c\u5e73\u306a\u6bd4\u8f03\u3092\u884c\u3046\u305f\u3081\u306b\u3001\u30a8\u30f3\u30b8\u30cb\u30a2\u306f\u5404\u30aa\u30d7\u30b7\u30e7\u30f3\u306b\u5fc5\u8981\u306a\u57fa\u672c\u30d1\u30e9\u30e1\u30fc\u30bf\u3092\u9078\u629e\u3057\u307e\u3059\u3002\u4ee5\u4e0b\u306e\u30c1\u30e3\u30fc\u30c8\u306e1\u3064\u306f\u30013\u3064\u306e\u5178\u578b\u7684\u306a\u30e6\u30cb\u30c3\u30c8\u306e\u9298\u677f\u30c7\u30fc\u30bf\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002.<\/p>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"6\">\n<caption>\u4e00\u822c\u7684\u306a\u96fb\u529b\u5909\u5727\u5668\u30af\u30e9\u30b9\u306e\u30b5\u30f3\u30d7\u30eb\u4ed5\u69d8<\/caption>\n<tbody>\n<tr>\n<th>\u30d1\u30e9\u30e1\u30fc\u30bf<\/th>\n<th>Distribution Unit<\/th>\n<th>Substation Power Unit<\/th>\n<th>GSU Unit<\/th>\n<\/tr>\n<tr>\n<td>\u5b9a\u683c\u96fb\u529b<\/td>\n<td>1,000 kVA<\/td>\n<td>20 MVA<\/td>\n<td>250 MVA<\/td>\n<\/tr>\n<tr>\n<td>Voltage ratio<\/td>\n<td>11\/0.4 kV<\/td>\n<td>110\/20 kV<\/td>\n<td>18\/400 kV<\/td>\n<\/tr>\n<tr>\n<td>\u30d9\u30af\u30c8\u30eb\u30b0\u30eb\u30fc\u30d7<\/td>\n<td>Dyn11<\/td>\n<td>YNd11<\/td>\n<td>YNd11<\/td>\n<\/tr>\n<tr>\n<td>\u30a4\u30f3\u30d4\u30fc\u30c0\u30f3\u30b9\u96fb\u5727<\/td>\n<td>6%<\/td>\n<td>10%<\/td>\n<td>14%<\/td>\n<\/tr>\n<tr>\n<td>\u7121\u8ca0\u8377\u640d\u5931<\/td>\n<td>\u22481,150 W<\/td>\n<td>\u224814 kW<\/td>\n<td>\u224890 kW<\/td>\n<\/tr>\n<tr>\n<td>\u8ca0\u8377\u640d\u5931<\/td>\n<td>\u224810,500 W<\/td>\n<td>\u224898 kW<\/td>\n<td>\u2248620 kW<\/td>\n<\/tr>\n<tr>\n<td>\u51b7\u5374<\/td>\n<td>ONAN<\/td>\n<td>ONAN\/ONAF<\/td>\n<td>ONAF\/ODAF<\/td>\n<\/tr>\n<tr>\n<td>Reference standard<\/td>\n<td>IEC 60076-1<\/td>\n<td>IEC 60076-1<\/td>\n<td>IEC 60076-1<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Loss assurance is important for people dealing with business: the loss value can improve or hinder the price of a transformer and can represent a 5%\u201310% difference as to the price of a transformer because a 1 kW difference in no-load losses over thirty years may cause the loss of tens of thousands of dollars.<\/p>\n<h2 id=\"roles\">The Unique Role of Each Transformer Class in the Power Grid<\/h2>\n<p>Each class is placed in its position in the energy chain, and none can be replaced with another one:<\/p>\n<ul>\n<li>GSU transformers \u2014 change the voltage produced by generators to the voltage for transmission at the generating plants and alternative sources site.<\/li>\n<li>Transmission step-down transformers function to interconnect high voltage and low voltage levels at major substations where they also regulate the voltage using on-load tap changers.<\/li>\n<li>Distribution transformers \u2014 are the last transformer which sets the voltage for consumption to 400\/230 V and therefore constitutes the largest number of transformers in the world.<\/li>\n<li>Auto-transformer \u2014 interconnects neighboring voltage levels like 220 kV and 110 kV but should be installed only when the grounding is available due to its design.<\/li>\n<li>Phase-shifting transformer \u2014 an important tool in dealing with the issue of power flow in a parallel corridors and used more and more in mesh high voltage networks.<\/li>\n<\/ul>\n<p>Distribution network designers say that up to 90 percent of losses in energy due to transformers happen in the distribution networks, which causes many countries (e.g. China and EU by virtue of GB 20052) to promote the use of amorphous core transformers with lower energy losses among the distribution transformers.<\/p>\n<h2 id=\"brands-prices\">Top Brands &amp; Realistic Price Ranges<\/h2>\n<p>Choosing a brand of power transformer comes down to balancing the initial purchase price, efficiency, lead time, and after-sales services that manufacturers provide. Well-known brands in the industry define the standard, whereas the oldest Chinese players provide approximately the same products that are compliant to IEC 60076 standards, but at 30%\u201350% lower prices.<\/p>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"6\">\n<caption>Power Transformer Brands &amp; Indicative Prices<\/caption>\n<tbody>\n<tr>\n<th>\u30d6\u30e9\u30f3\u30c9<\/th>\n<th>Headquarters<\/th>\n<th>Strength<\/th>\n<th>Indicative Price (20 MVA, 110 kV)<\/th>\n<\/tr>\n<tr>\n<td>ABB \/ Hitachi Energy<\/td>\n<td>Switzerland \/ Japan<\/td>\n<td>HVDC, EHV expertise<\/td>\n<td>$450,000\u2013$700,000<\/td>\n<\/tr>\n<tr>\n<td>\u30b7\u30fc\u30e1\u30f3\u30b9\u30a8\u30ca\u30b8\u30fc<\/td>\n<td>\u30c9\u30a4\u30c4<\/td>\n<td>EHV and digital substations<\/td>\n<td>$430,000\u2013$680,000<\/td>\n<\/tr>\n<tr>\n<td>\u30b7\u30e5\u30ca\u30a4\u30c0\u30fc\u30a8\u30ec\u30af\u30c8\u30ea\u30c3\u30af<\/td>\n<td>\u30d5\u30e9\u30f3\u30b9<\/td>\n<td>Distribution, EcoStruxure<\/td>\n<td>$280,000\u2013$450,000<\/td>\n<\/tr>\n<tr>\n<td>GE Vernova \/ Prolec GE<\/td>\n<td>USA \/ Mexico<\/td>\n<td>Utility-scale GSU<\/td>\n<td>$420,000\u2013$650,000<\/td>\n<\/tr>\n<tr>\n<td>TBEA<\/td>\n<td>\u4e2d\u56fd<\/td>\n<td>Large MVA, global EPC projects<\/td>\n<td>$180,000\u2013$320,000<\/td>\n<\/tr>\n<tr>\n<td>\u6c5f\u8607\u7701\u8607\u8fba\u96fb\u529b<\/td>\n<td>\u4e2d\u56fd<\/td>\n<td>Custom 50 kVA\u2013220 kV class, OEM\/ODM<\/td>\n<td>$160,000\u2013$300,000<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The pricing is not exact; it&#8217;s going to be variable depending on specification, loss levels and location. Thus, all these values given below should be understood as guides rather than fixed prices. Jiangsu Subian Electric Power offers transformers ranging from 50 kVA to 220 kV class with multiple options including dry-type and oil-filled transformers. The company provides a lot of additional advantages; first, they offer prices that are 30-50% lower compared to Europe; secondly, their distributors keep deadlines and deliver to over 60 countries of the world.<\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-366\" src=\"https:\/\/subian-electric.com\/wp-content\/uploads\/2026\/08\/How-to-Choose-the-Right-Transformer-Class-for-Your-Project.webp\" alt=\"How to Choose the Right Transformer Class for Your Project\" width=\"1448\" height=\"1086\" \/><\/p>\n<h2 id=\"how-to-choose\">How to Choose the Right Transformer Class for Your Project<\/h2>\n<ul>\n<li>Define the duty \u2014 a GSU, transmission, or distribution role resolves the entire design envelope.<\/li>\n<li>Check the voltage levels and tap range \u2014 establish the nominal ratio, \u00b110% to \u00b116% on-load tap range, and vector group with respect to your network.<\/li>\n<li>Calculate the load profile \u2014 determine the kVA\/MVA size so that peak load lies between 60%\u201380% of the rating for the highest efficiency and margin.<\/li>\n<li>Establish loss budgets \u2014 ask for the no-load and load loss guarantees and carry out capitalized-loss comparison for a span of 20\u201330 years.<\/li>\n<li>Select cooling and insulation \u2014 ONAN for regular outdoor duty; ONAN\/ONAF for overload flexibility; dry-type within the building.<\/li>\n<li>Check standards \u2014 obtain IEC 60076 series type tests (dielectric, temperature rise, short-circuit) and factory test papers.<\/li>\n<li>Consider access and transport \u2014 a 40 MVA unit has a weight of 40\u201360 tons and may need special transportations and labor study.<\/li>\n<\/ul>\n<h2 id=\"faq\">\u3088\u304f\u3042\u308b\u8cea\u554f<\/h2>\n<h3>What is the difference between a power transformer and a distribution transformer?<\/h3>\n<p>Power transformers manage high capacities (generally over 200 kVA) at the transmission or sub-transmission level and are built for full-load operation with voltage regulation; a distribution transformer is the last step-down transformer (normally 5 kVA\u20132,500 kVA) that reaches end users and operates mostly at partial load. Distribution transformers greatly outnumber power transformers; there are millions of them in the world while power transformers make the most valuable part of the substation.<\/p>\n<h3>What does the turns ratio of a transformer mean in classification?<\/h3>\n<p>The turns ratio N1\/N2 is equal to the primary-to-secondary voltage ratio at no-load conditions which provides a true indication as to whether the transformer is a step-up transformer (i.e. N2 &gt; N1), a step-down transformer (i.e. N1 &gt; N2) or if it is an isolation transformer operating at 1:1 ratio. For example, the transformer having 110 kV\/20 kV rating will have a ratio of 5.5:1 whereas GSU transformer stepping voltage down from 18 kV to 400 kV will have a ratio of around 22:1.<\/p>\n<h3>Which cooling class is best for a 20 MVA substation transformer?<\/h3>\n<p>The majority of electricity providers opt for ONAN\/ONAF models, as its normal load is supported by natural cooling and forced air cooling (usually in the range of 120%-135% of the ONAN rating) accommodates peak loads and temporary overloads. Complete OFAF\/ODAF designs include a pump and the oil&#8217;s movement direction, increasing both the efficiency as well as its maintenance costs.<\/p>\n<h3>How much does a power transformer cost in 2025?<\/h3>\n<p>The majority of electricity providers opt for ONAN\/ONAF models, as its normal load is supported by natural cooling and forced air cooling (usually in the range of 120%-135% of the ONAN rating) accommodates peak loads and temporary overloads. Complete OFAF\/ODAF designs include a pump and the oil&#8217;s movement direction, increasing both the efficiency as well as its maintenance costs.<\/p>\n<h3>Do I need an oil-immersed or a dry-type transformer?<\/h3>\n<p>When it comes to outdoor substations with capacities greater than 2 MVA, the most cost-effective option is oil-immersed type. However, within the indoor or high-rise applications such as fire-sensitive locations and offshore buildings, dry-type varieties should be used since oil containment and fire suppression are thus difficult to achieve. So, while a 1 MVA cast resin unit may cost $28,000\u2013$70,000, oil-immersed units are generally sold in the range of $ 18,000 to $45,000.<\/p>\n<h2 id=\"references\">\u53c2\u8003\u6587\u732e<\/h2>\n<ul>\n<li><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/639\" rel=\"nofollow noopener\" target=\"_blank\">IEC 60076-1: Power transformers \u2014 General<\/a> \u2014 The international standard defining ratings, tolerances, and test procedures for power transformers.<\/li>\n<li><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/642\" rel=\"nofollow noopener\" target=\"_blank\">IEC 60076-2: Temperature rise<\/a> \u2014 Specifies temperature-rise limits and cooling classes used in transformer classification.<\/li>\n<li><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/644\" rel=\"nofollow noopener\" target=\"_blank\">IEC 60076-3: Insulation levels and dielectric tests<\/a> \u2014 Defines BIL and dielectric test requirements per voltage class.<\/li>\n<li><a href=\"https:\/\/ieeexplore.ieee.org\/document\/5307241\" rel=\"nofollow noopener\" target=\"_blank\">IEEE C57.12.00: General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers<\/a> \u2014 The North American companion standard to IEC 60076.<\/li>\n<li><a href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\" rel=\"nofollow noopener\" target=\"_blank\">NFPA 70: National Electrical Code<\/a> \u2014 Governs transformer installation, clearances, and protection in the United States.<\/li>\n<li><a href=\"https:\/\/www.hitachienergy.com\/products-and-solutions\/transformers\" rel=\"nofollow noopener\" target=\"_blank\">Hitachi Energy Transformer Portfolio<\/a> \u2014 Reference for modern EHV, HVDC, and generator transformer technology.<\/li>\n<\/ul>\n<h2 id=\"conclusion\">\u7d50\u8ad6<\/h2>\n<p>It is crucial to understand the importance of power transformer classification. This is the biggest factor that will determine whether one will buy correct equipment. The function of transformer, voltage class, winding configuration, cooling method, and insulation type will indicate the presence of the transformer in the grid, amount of load, and its price \u2014 starting from $1,500 for distribution transformers and ending with $2.5 million for EHV transformers.<\/p>\n<ul>\n<li>First of all, it is important to categorize equipment according to its function (GSU, transmission transformer, distribution transformer, and auto transformer), then according to its voltage, cooling method, and insulation type.<\/li>\n<li>Cooling class should be aligned to load profile of the transformer. Best flexibility-cost ratio for the transformer of up to 150 MVA is ONAN\/ONAF.<\/li>\n<li>It is required to follow IEC 60076 in the contract for loss reserves, dielectric tests, and short circuit testing.<\/li>\n<li>There should be at least three suppliers compared according to the price for the MVA, capital loss estimation, and delivery period.<\/li>\n<\/ul>\n<p>If your project needs distribution or power transformers from 50 kVA to 220 kV class with custom ratios and IEC type-test documentation, contact <a href=\"https:\/\/subian-electric.com\/ja\/\">\u6c5f\u8607\u7701\u8607\u8fba\u96fb\u529b<\/a> for a direct factory quotation and engineering consultation.<\/p>","protected":false},"excerpt":{"rendered":"<p>When the substation engineer looks at the document for a tender concerning the 132 kV transmission upgrade, one of the first specification sheets being reviewed is normally the power transformer classification table since a wrong choice can cost up to hundreds of thousands as well as cause months of delay in the commissioning process. Each of the types of power transformer classification is created to address a particular problem in terms of voltage, load, and reliability no matter whether it is a 10 MVA distribution unit operating in a block of factory factories or a 400 MVA generator step-up transformer installed at a coal power plant. The provided article describes [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":364,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[77],"tags":[],"class_list":["post-363","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/subian-electric.com\/ja\/wp-json\/wp\/v2\/posts\/363","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/subian-electric.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/subian-electric.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/subian-electric.com\/ja\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/subian-electric.com\/ja\/wp-json\/wp\/v2\/comments?post=363"}],"version-history":[{"count":2,"href":"https:\/\/subian-electric.com\/ja\/wp-json\/wp\/v2\/posts\/363\/revisions"}],"predecessor-version":[{"id":11038,"href":"https:\/\/subian-electric.com\/ja\/wp-json\/wp\/v2\/posts\/363\/revisions\/11038"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/subian-electric.com\/ja\/wp-json\/wp\/v2\/media\/364"}],"wp:attachment":[{"href":"https:\/\/subian-electric.com\/ja\/wp-json\/wp\/v2\/media?parent=363"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/subian-electric.com\/ja\/wp-json\/wp\/v2\/categories?post=363"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/subian-electric.com\/ja\/wp-json\/wp\/v2\/tags?post=363"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}