{"id":10744,"date":"2026-08-29T23:43:19","date_gmt":"2026-08-29T15:43:19","guid":{"rendered":"https:\/\/q8bbzjnpm5.wpdns.site\/?p=10744"},"modified":"2026-08-29T23:43:19","modified_gmt":"2026-08-29T15:43:19","slug":"jiangsu-subian-power-equipment-co-ltd-achieves-remarkable-progress-in-the-field-of-dry-type-transformers","status":"publish","type":"post","link":"https:\/\/subian-electric.com\/ko\/news\/jiangsu-subian-power-equipment-co-ltd-achieves-remarkable-progress-in-the-field-of-dry-type-transformers\/","title":{"rendered":"\uc7a5\uc464 \uc218\ube44\uc548 \uc804\ub825 \uc7a5\ube44 \uc720\ud55c\ud68c\uc0ac, \uac74\uc2dd \ubcc0\uc555\uae30 \ubd84\uc57c\uc5d0\uc11c \ub208\uc5d0 \ub744\ub294 \ubc1c\uc804\uc744 \uc774\ub8e8\ub2e4"},"content":{"rendered":"<p>2024\ub144 \uaca8\uc6b8 \uc2dc\uc98c\uc5d0, \ub3d9\ub0a8\uc544\uc2dc\uc544\uc758 \ud55c \ubc30\uc804 \uc720\ud2f8\ub9ac\ud2f0\ub294 \uc18c\uaddc\ubaa8 \ub3c4\uc2dc \ubcc0\uc804\uc18c \ub0b4\uc5d0\uc11c \ud654\uc7ac\ub85c \uc190\uc0c1\ub41c \uc624\uc77c \uce68\uc9c0 \ubcc0\uc555\uae30\ub97c 1,000 kVA\uc758 \uac74\uc2dd \ubcc0\uc555\uae30\ub85c \uad50\uccb4\ud558\ub294 \uc791\uc5c5\uc744 \uc218\ud589\ud588\uc2b5\ub2c8\ub2e4. \uc774 \ubcc0\uc555\uae30\ub294 \uc720\ud2f8\ub9ac\ud2f0\uc5d0 \uc758\ud574 2\ub144 \ub3d9\uc548 \uc870\uc6a9\ud788 \uac80\uc99d\ub41c \uacf5\uae09\uc5c5\uccb4\uc5d0\uc11c \uc81c\uc870\ud55c \uac83\uc785\ub2c8\ub2e4. \uc8fc\ubaa9\ud560 \ub9cc\ud55c \uc810\uc740 \uc0c8\ub85c\uc6b4 \ubcc0\uc555\uae30\uc758 \uc2dc\uc6b4\uc804\uc774 \ub2e8 4\uc77c \ub9cc\uc5d0 \uc644\ub8cc\ub418\uc5c8\uc73c\uba70, 8\uc2dc\uac04\uc758 \ubd80\ud558 \uc6b4\uc804 \ub3d9\uc548 78\ub3c4 K \uc774\ud558\uc5d0\uc11c 100\ub3c4 C\uc758 \uc628\ub3c4 \uc0c1\uc2b9\uc744 \uc720\uc9c0\ud588\ub2e4\ub294 \uac83\uc785\ub2c8\ub2e4. \ubcc0\uc555\uae30\uc640 \ud568\uaed8 IEC 60076-11 \uc720\ud615 \uc2dc\ud5d8 \ubcf4\uace0\uc11c, \uc815\uae30 \uc2dc\ud5d8 \uc778\uc99d\uc11c \ubc0f \uac01 \ud0ed\uc5d0 \ub300\ud55c \uad8c\uc120 \uc800\ud56d \ub370\uc774\ud130 \ud615\ud0dc\uc758 \ud544\uc694\ud55c \ubb38\uc11c\ub3c4 \ud568\uaed8 \ubc30\uc1a1\ub418\uc5c8\uc2b5\ub2c8\ub2e4. \ubcc0\uc555\uae30\uc758 \uacf5\uae09\uc5c5\uccb4\ub294 Jiangsu Subian Power\ub85c, \uc218\ub144\uac04 \uac74\uc2dd \ubcc0\uc555\uae30 \uc2dc\uc7a5\uc5d0\uc11c \uc798 \uc54c\ub824\uc9c4 \uc774\ub984\uc785\ub2c8\ub2e4.<\/p>\n<p>\uc774 \uae30\uc0ac\ub294 Jiangsu Subian Electric Power\uac00 \uac74\uc2dd \ubcc0\uc555\uae30 \ubd84\uc57c\uc5d0\uc11c \ub2ec\uc131\ud55c \uc9c4\uc804\uc744 \ubd84\uc11d\ud558\ub294 \uac83\uc744 \ubaa9\ud45c\ub85c \ud569\ub2c8\ub2e4: \uc5d4\uc9c0\ub2c8\uc5b4\ub9c1 \uc774\uc815\ud45c, \ud604\uc7ac\uc758 \uc81c\ud488 \ub77c\uc778, \uc8fc\uc7a5 \ub4a4\uc5d0 \uc788\ub294 \uc2dc\ud5d8 \ubc0f \ud488\uc9c8 \uc778\ud504\ub77c, \uadf8\ub9ac\uace0 \ub2e8\uc21c\ud55c \uc9c0\uc5ed \ud50c\ub808\uc774\uc5b4\uc5d0\uc11c \uc9c4\uc9c0\ud55c \uc218\ucd9c \uacf5\uae09\uc790\ub85c\uc758 \ubcc0\ud654\ub97c \ub098\ud0c0\ub0b4\ub294 \uc2dc\uc7a5 \uc2e0\ud638\ub4e4\uc785\ub2c8\ub2e4. \uc911\uad6d\uc758 \uac74\uc2dd \ubcc0\uc555\uae30 \uc81c\uc870\uc5c5\uccb4\ub97c \uc120\ud0dd\ud560 \uacc4\ud68d\uc774\ub77c\uba74, \uc774 \uae30\uc0ac\ub97c \uc2dc\ud5d8 \ubcf4\uace0\uc11c, \uc0ac\uc591 \ubc0f \ubc30\uc1a1 \uc11c\ube44\uc2a4 \uce21\uba74\uc5d0\uc11c\uc758 \uc131\ub2a5\uc744 \ud3ec\ud568\ud558\uc5ec \u201c\uc8fc\ubaa9\ud560 \ub9cc\ud55c \uc9c4\uc804\u201d\uc73c\ub85c \uace0\ub824\ud574\uc57c \ud560 \uc0ac\ud56d\uc5d0 \ub300\ud55c \uc2e4\uc6a9\uc801\uc778 \uac00\uc774\ub4dc\ub85c \ud65c\uc6a9\ud560 \uc218 \uc788\uc2b5\ub2c8\ub2e4.<\/p>\n<blockquote><p>\uc694\uc57d\ud558\uc790\uba74, Jiangsu Subian Electric Power Co., Ltd.\ub294 \ubcc0\uc555\uae30 \uc81c\uc870\uc5c5\uccb4\ub85c, 30 kVA\uc5d0\uc11c 10,000 kVA\uae4c\uc9c0\uc758 \uad11\ubc94\uc704\ud55c \uac74\uc2dd \ubcc0\uc555\uae30\ub97c \uc81c\uacf5\ud558\uba70, 10 kV\u201335 kV \ub4f1\uae09\uc758 \uce90\uc2a4\ud2b8 \uc218\uc9c0 \uc808\uc5f0 \ubc0f VPI \uc808\uc5f0\uc744 F (100 K) \ubc0f H (125 K) \uc808\uc5f0 \uc720\ud615\uc5d0 \ub530\ub77c IEC 60076-11\uc5d0 \ub9de\ucdb0 \uc81c\uacf5\ud569\ub2c8\ub2e4. \uc774 \uc81c\uc870\uc5c5\uccb4\ub294 \uc544\uc2dc\uc544, \uc544\ud504\ub9ac\uce74, \uc911\ub3d9 \ubc0f \ub77c\ud2f4 \uc544\uba54\ub9ac\uce74\uc758 \uc218\ucd9c \uc2dc\uc7a5\uc5d0 \ub300\ud574 \uc720\ud615 \uc2dc\ud5d8 \ubc0f \uc815\uae30 \uc2dc\ud5d8 \ubcf4\uace0\uc11c\uc640 \uacf5\uc7a5 \uc218\uc6a9 \uce21\uc815\uce58\ub97c \ud3ec\ud568\ud55c \uc804\uccb4 \uc2dc\ud5d8 \ubb38\uc11c\ub3c4 \uc81c\uacf5\ud569\ub2c8\ub2e4.<\/p><\/blockquote>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-10745\" src=\"https:\/\/subian-electric.com\/wp-content\/uploads\/2026\/08\/Jiangsu-Subian-Power-Equipment-Co-Ltd-Achieves-Remarkable-Progress-In-The-Field-Of-Dry-Type-Transformers.webp\" alt=\"\uc7a5\uc464 \uc218\ube44\uc548 \uc804\ub825 \uc7a5\ube44 \uc720\ud55c\ud68c\uc0ac\uac00 \uac74\uc2dd \ubcc0\uc555\uae30 \ubd84\uc57c\uc5d0\uc11c \ub208\uc5d0 \ub744\ub294 \ubc1c\uc804\uc744 \uc774\ub8e8\uc5c8\uc2b5\ub2c8\ub2e4\" width=\"1448\" height=\"1086\" \/><\/p>\n<hr \/>\n<h2 id=\"background\">\ubc30\uacbd: \ubcc0\uc555\uae30 \uc81c\uc870\uc5c5\uccb4\uc758 \uacbd\ub85c<\/h2>\n<p>Jiangsu Subian Electric Power Co., Ltd.\ub294 \uc911\uad6d \uc7a5\uc464\uc131\uc5d0 \uc704\uce58\ud558\uace0 \uc788\uc73c\uba70, \uc5ed\uc0ac\uc801\uc73c\ub85c \uad6d\uac00 \ub0b4\uc5d0\uc11c \ubcc0\uc555\uae30 \uacf5\ud559\uc758 \uac00\uc7a5 \ubc00\uc9d1\ub41c \uc9c0\uc5ed \uc911 \ud558\ub098\ub85c \uac04\uc8fc\ub420 \uc218 \uc788\uc2b5\ub2c8\ub2e4. \uc774 \ud68c\uc0ac\ub294 \ubc30\uc804 \ubcc0\uc555\uae30\ub85c \ud65c\ub3d9\uc744 \uc2dc\uc791\ud588\uc73c\uba70, 10 kV\uc5d0\uc11c 110 kV\uae4c\uc9c0\uc758 \uc804\uc555 \ub4f1\uae09\uc744 \uac00\uc9c4 \uc624\uc77c \uce68\uc9c0 \uc720\ub2db\uc5d0\uc11c \uc131\uacf5\uc744 \uac70\ub450\uc5c8\uc2b5\ub2c8\ub2e4. \uac74\uc2dd \uc0dd\uc0b0\uc73c\ub85c\uc758 \uc804\ud658\uc740 \ub2e4\uc74c \ub2e8\uacc4\uac00 \ub418\uc5c8\uc73c\uba70, \ubc29\ud654 \ubcc0\uc555\uae30\uc5d0 \ub300\ud55c \uc218\uc694\ub85c \uc778\ud574 \uac74\uc2dd \uc2dc\uc7a5\uc774 \uc624\uc77c \uae30\ubc18 \uc81c\ud488\ubcf4\ub2e4 \ub354 \ube60\ub974\uac8c \uc131\uc7a5\ud558\uac8c \ub418\uc5c8\uace0 \ub450 \uc0dd\uc0b0 \ub77c\uc778\uc758 \ub9ce\uc740 \uae30\uc220\uc801 \uce21\uba74(\uc608: \ucf54\uc5b4 \ubc30\uce58, \uad8c\uc120 \uae30\uc220, \uc2dc\ud5d8 \uc7a5\ube44 \ub4f1)\uc774 \uc720\uc0ac\ud569\ub2c8\ub2e4.<\/p>\n<p>\u201c\uc624\ud504\ub77c\uc778 \uc0dd\uc0b0 \uc81c\uacf5\u201d\uc5d0\uc11c \u201c\uc9c4\uc9c0\ud55c \ub4dc\ub77c\uc774 \ud0c0\uc785 \uc0dd\uc0b0\uc790\u201d\ub85c\uc758 \ubcc0\ud654\ub97c \uc99d\uba85\ud558\ub294 \ub124 \uac00\uc9c0 \uc774\ub3d9 \ubc29\ud5a5\uc774 \uc788\uc2b5\ub2c8\ub2e4: \uc0dd\uc0b0 \ud604\uc7a5, \ud14c\uc2a4\ud2b8 \ub2a5\ub825, \uc778\uc99d \ubc0f \uc218\ucd9c \ubb38\uc11c \ud68d\ub4dd. \uc774 \uc911 \uc5b4\ub290 \uac83\ub3c4 \ube0c\ub85c\uc154\ub85c \uc704\uc870\ud560 \uc218 \uc5c6\uc73c\uba70, \uc774 \ubaa8\ub4e0 \ubd84\uc57c\ub294 \ucd5c\uadfc \uba87 \ub144 \ub3d9\uc548 \ub208\uc5d0 \ub744\uac8c \ubc1c\uc804\ud588\uc2b5\ub2c8\ub2e4.<\/p>\n<h2 id=\"milestones\">\ub4dc\ub77c\uc774 \ud0c0\uc785 \uc5ec\uc815\uc758 \uc8fc\uc694 \uc774\uc815\ud45c<\/h2>\n<table>\n<thead>\n<tr>\n<th>\uc774\uc815\ud45c<\/th>\n<th>\ubb34\uc5c7\uc774 \ubc14\ub00c\uc5c8\ub294\uac00<\/th>\n<th>\uad6c\ub9e4\uc790\uc5d0\uac8c \uc911\uc694\ud55c \uc774\uc720<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\uc815\uaca9 \ud655\uc7a5<\/td>\n<td>\ubc94\uc704\uac00 30 kVA\uc5d0\uc11c 10,000 kVA\ub85c \uc99d\uac00\ud588\uc2b5\ub2c8\ub2e4.<\/td>\n<td>\uc18c\uaddc\ubaa8 \ubc0f \ub300\uaddc\ubaa8 \ud504\ub85c\uc81d\ud2b8\ub97c \uc704\ud55c \ub2e8\uc77c \uacf5\uae09\uc5c5\uccb4<\/td>\n<\/tr>\n<tr>\n<td>\uc804\uc555 \ud074\ub798\uc2a4 \ubc94\uc704<\/td>\n<td>10 kV, 20 kV, 35 kV \ud074\ub798\uc2a4<\/td>\n<td>\ub300\ubd80\ubd84\uc758 \uae00\ub85c\ubc8c \ubc30\uc804 \ub124\ud2b8\uc6cc\ud06c\uc640 \uc77c\uce58<\/td>\n<\/tr>\n<tr>\n<td>\uc774\uc911 \uc808\uc5f0 \uae30\uc220<\/td>\n<td>\uc8fc\uc870 \uc218\uc9c0(SCB \uc2dc\ub9ac\uc988) \ubc0f VPI(SG \uc2dc\ub9ac\uc988) \ubaa8\ub450<\/td>\n<td>\ubc29\ud654 \ub4f1\uae09 \ubc0f \uc608\uc0b0 \ud504\ub85c\uc81d\ud2b8\ub97c \uc704\ud55c \uc720\uc5f0\ud55c \uc0ac\uc591<\/td>\n<\/tr>\n<tr>\n<td>IEC 60076-11 \uc900\uc218<\/td>\n<td>\ub300\ud45c \uc815\uaca9\uc5d0 \ub300\ud55c \uc720\ud615 \ud14c\uc2a4\ud2b8<\/td>\n<td>\ubb38\uc11c\ud654\ub41c, \ubc29\uc5b4 \uac00\ub2a5\ud55c \ud488\uc9c8 \uc8fc\uc7a5<\/td>\n<\/tr>\n<tr>\n<td>\uc218\ucd9c \ubb38\uc11c \uc2dc\uc2a4\ud15c<\/td>\n<td>\ud45c\uc900\ud654\ub41c \ud14c\uc2a4\ud2b8 \ubcf4\uace0\uc11c, \ub3c4\uba74 \ubc0f \uc778\uc99d\uc11c<\/td>\n<td>\ub354 \ube60\ub978 \ud504\ub85c\uc81d\ud2b8 \uc2b9\uc778 \ubc0f \ucee4\ubbf8\uc154\ub2dd<\/td>\n<\/tr>\n<tr>\n<td>\uace0\ud6a8\uc728 \ucf54\uc5b4<\/td>\n<td>\ube44\uc815\uc9c8 \ud569\uae08 \ucf54\uc5b4 \ub4dc\ub77c\uc774 \ud0c0\uc785 \ucd94\uac00<\/td>\n<td>\ub9ce\uc740 \uc2dc\uc7a5\uc5d0\uc11c \uc0c8\ub85c\uc6b4 \uc190\uc2e4 \uaddc\uc815\uc744 \ucda9\uc871<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-10746\" src=\"https:\/\/subian-electric.com\/wp-content\/uploads\/2026\/08\/Key-Milestones-in-the-Dry-Type-Journey.webp\" alt=\"\ub4dc\ub77c\uc774 \ud0c0\uc785 \uc5ec\uc815\uc758 \uc8fc\uc694 \uc774\uc815\ud45c\" width=\"1448\" height=\"1086\" \/><\/p>\n<h2 id=\"product\">\ub4dc\ub77c\uc774 \ud0c0\uc785 \uc81c\ud488 \ub77c\uc778 \ubc0f \ub2a5\ub825<\/h2>\n<table>\n<thead>\n<tr>\n<th>\uc2dc\ub9ac\uc988<\/th>\n<th>\uc808\uc5f0<\/th>\n<th>\uc815\uaca9 \ubc94\uc704<\/th>\n<th>\uc77c\ubc18\uc801\uc778 \uc751\uc6a9<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>SCB \uc2dc\ub9ac\uc988(\uc8fc\uc870 \uc218\uc9c0)<\/td>\n<td>F \ud074\ub798\uc2a4(100 K) \/ H \ud074\ub798\uc2a4(125 K)<\/td>\n<td>30\u20136,300 kVA<\/td>\n<td>\uac74\ubb3c, \ubcd1\uc6d0, \ub370\uc774\ud130 \uc13c\ud130<\/td>\n<\/tr>\n<tr>\n<td>SG \uc2dc\ub9ac\uc988(VPI)<\/td>\n<td>H \ud074\ub798\uc2a4(125 K)<\/td>\n<td>50\u201310,000 kVA<\/td>\n<td>\uc0b0\uc5c5 \ud50c\ub79c\ud2b8, \uad11\uc5c5<\/td>\n<\/tr>\n<tr>\n<td>SC(B) \ube44\uc815\uc9c8 \ucf54\uc5b4<\/td>\n<td>F \ud074\ub798\uc2a4<\/td>\n<td>100\u20132,500 kVA<\/td>\n<td>\uc800\uc190\uc2e4, \uce5c\ud658\uacbd \uc778\uc99d \ud504\ub85c\uc81d\ud2b8<\/td>\n<\/tr>\n<tr>\n<td>\uace0\uc804\uc555 \ub4dc\ub77c\uc774 \ud0c0\uc785<\/td>\n<td>F\/H \ud074\ub798\uc2a4<\/td>\n<td>\ucd5c\ub300 35 kV \ud074\ub798\uc2a4<\/td>\n<td>\uc7ac\uc0dd \uac00\ub2a5 \uc5d0\ub108\uc9c0, \ub3c4\uc2dc \ubcc0\uc804\uc18c<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\uc9c4\uc804\uc744 \uce21\uc815\ud558\ub294 \uac83\uc740 \uc815\uaca9 \uc2dc\uc2a4\ud15c\uc785\ub2c8\ub2e4. \uc18c\ud615 \uc8fc\uc870 \uc218\uc9c0 \uc720\ub2db\uc5d0\uc11c 10,000 kVA VPI \ubcc0\uc555\uae30\ub85c \uc131\uc7a5\ud558\ub294 \uacfc\uc815\uc740 \ud2b9\uc815 \ubc14\ub2e5, \ub9c8\uc2a4\ud130\ub9c8\uc778\ub4dc \ud14c\uc2a4\ud2b8 \ubca0\ub4dc \ubc0f \uc815\ubc00 \uacf5\ucc28\ub85c \uc548\uc815\uc801\uc778 \uc7a5\ub825\uc744 \uc0dd\uc0b0\ud560 \uc218 \uc788\ub294 \uad8c\uc120 \uc791\uc5c5\uc7a5\uc774 \ud544\uc694\ud55c \ud2b9\ubcc4\ud55c \uc9c4\uacf5 \uc8fc\uc870 \ubc0f \uce68\ud22c \uc7a5\ube44\ub97c \uc694\uad6c\ud569\ub2c8\ub2e4. \uc5b8\uae09\ub41c \uc131\uacf5\uc801\uc778 \uc0dd\uc0b0 \uacb0\uacfc\uc640 \uce74\ud0c8\ub85c\uadf8\uac00 \uc544\ub2cc, \uc81c\uc870\uc5c5\uccb4\uac00 \ub300\uaddc\ubaa8 \uc81c\ud488\uc744 \uc790\uc2e0 \uc788\uac8c \uc778\uc6a9\ud560 \uc218 \uc788\uac8c \ud569\ub2c8\ub2e4.<\/p>\n<h2 id=\"technology\">\uc8fc\uc870 \uc218\uc9c0 \ub300 VPI: \uc218\ube44\uc548\uc774 \uad6c\ucd95\ud558\ub294 \ub450 \uac00\uc9c0 \uae30\uc220<\/h2>\n<p>\ub450 \uac00\uc9c0 \ub4dc\ub77c\uc774 \uae30\uc220\uc744 \uc54c\uba74, \uc218\ube44\uc548\uc744 \ud3ec\ud568\ud55c \ubaa8\ub4e0 \uc81c\uc870\uc5c5\uccb4\uc758 \uc8fc\uc7a5\uc744 \ud574\uc11d\ud560 \uc218 \uc788\uc2b5\ub2c8\ub2e4.<\/p>\n<ul>\n<li>\uc8fc\uc870 \uc218\uc9c0(SCB): \uc774 \uacfc\uc815\uc5d0\uc11c HV \uad8c\uc120\uc740 \uc2e4\ub9ac\uce74 \ud544\ub7ec\uac00 \ud3ec\ud568\ub41c \uc5d0\ud3ed\uc2dc \uc218\uc9c0\ub85c \uc9c4\uacf5\uc5d0\uc11c \uc8fc\uc870\ub418\uc5b4, \ud6cc\ub96d\ud55c \uae30\uacc4\uc801 \ud2b9\uc131\uacfc \uc6b0\uc218\ud55c \ubd80\ubd84 \ubc29\uc804 \uc131\ub2a5\uc744 \uac00\uc9c4 \ub2e8\ub2e8\ud558\uace0 \ubc00\ud3d0\ub41c \ucf54\uc77c\uc744 \ud615\uc131\ud569\ub2c8\ub2e4. \uc2b5\uae30\uc640 \ud654\uc7ac \uc704\ud5d8\uc774 \uc911\uc694\ud55c \uc2e4\ub0b4 \uc751\uc6a9\uc5d0 \uac00\uc7a5 \uc801\ud569\ud569\ub2c8\ub2e4. \uc628\ub3c4\ub294 F \ud074\ub798\uc2a4\uc758 100K \uc218\uc900\uc5d0\uc11c \uc791\ub3d9\ud569\ub2c8\ub2e4.<\/li>\n<li>VPI(SG): \uc774 \uacfc\uc815\uc5d0\uc11c\ub294 \uac1c\ubc29 \uad8c\uc120 \uc640\uc774\uc5b4\uac00 \ud3f4\ub9ac\uc5d0\uc2a4\ud130 \ub610\ub294 \uc5d0\ud3ed\uc2dc \ubc14\ub2c8\uc2dc\ub85c \uc9c4\uacf5 \uc555\ub825 \ud558\uc5d0 \uce68\ud22c\ub429\ub2c8\ub2e4. \uc774 \ubc29\ubc95\uc740 \uc8fc\uc870 \uc218\uc9c0 \uae30\uc220\uc5d0 \ube44\ud574 \ube44\uc6a9\uc774 \uc800\ub834\ud558\uba70, \uacfc\ubd80\ud558 \uc6a9\ub7c9\uc774 \ub354 \uc88b\uace0 \ubb38\uc81c\uac00 \ubc1c\uc0dd\ud588\uc744 \ub54c \uc218\ub9ac\ud558\uae30\uac00 \ub354 \uc27d\uc2b5\ub2c8\ub2e4. \uc77c\ubc18\uc801\uc73c\ub85c \uc0b0\uc5c5 \ubd84\uc57c \ubc0f H \ud074\ub798\uc2a4 \uc751\uc6a9\uc5d0 \uc0ac\uc6a9\ub418\uba70, \uc791\ub3d9 \uc628\ub3c4\ub294 125K\uae4c\uc9c0 \uc0c1\uc2b9\ud569\ub2c8\ub2e4.<\/li>\n<\/ul>\n<p>\ub450 \uac00\uc9c0 \uae30\uc220\uc744 \ubaa8\ub450 \uc81c\uacf5\ud558\ub294 \uc81c\uc870\uc5c5\uccb4\uc778 \uc218\ube44\uc548\uc740 \ud504\ub85c\uc81d\ud2b8 \uc5d4\uc9c0\ub2c8\uc5b4\uac00 \ud558\ub098\uc758 \uc194\ub8e8\uc158\uc5d0 \uc5bd\ub9e4\uc774\uc9c0 \uc54a\uace0 \ud544\uc694\ud55c \uae30\uc220\uc744 \uc120\ud0dd\ud560 \uc218 \uc788\ub294 \uc720\uc5f0\uc131\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4.<\/p>\n<h2 id=\"quality\">\ud488\uc9c8 \uc778\ud504\ub77c: \ud14c\uc2a4\ud2b8 \ubc0f \uc778\uc99d<\/h2>\n<p>\uac74\uc2dd \ubcc0\uc555\uae30\ub294 \uac00\uc7a5 \uc911\uc694\ud55c \ub124 \uac00\uc9c0 \ud14c\uc2a4\ud2b8 \ud504\ub85c\uc138\uc2a4\ub97c \uac00\uc9c0\uace0 \uc788\uc73c\uba70, \ubaa8\ub4e0 \uc2e0\ub8b0\ud560 \uc218 \uc788\ub294 \uc0dd\uc0b0 \uc2dc\uc124\uc740 \uc774\ub97c \uc54c\uace0 \uc788\uc2b5\ub2c8\ub2e4:<\/p>\n<table>\n<thead>\n<tr>\n<th>\ud14c\uc2a4\ud2b8<\/th>\n<th>\ud45c\uc900<\/th>\n<th>\uc218\uc6a9 \uae30\uc900 (\uc77c\ubc18\uc801)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\ubd80\ubd84 \ubc29\uc804<\/td>\n<td>IEC 60076-11<\/td>\n<td>\uc815\uaca9 \uc804\uc555 1.1 \u00d7\uc5d0\uc11c 10 pC \uc774\ud558<\/td>\n<\/tr>\n<tr>\n<td>\ub099\ub8b0 \uc784\ud384\uc2a4<\/td>\n<td>IEC 60076-4<\/td>\n<td>\uc9c0\uc815\ub41c LI \uc218\uc900\uc5d0\uc11c \uace0\uc7a5\uc774 \ubc1c\uc0dd\ud558\uc9c0 \uc54a\uc74c<\/td>\n<\/tr>\n<tr>\n<td>\uc628\ub3c4 \uc0c1\uc2b9<\/td>\n<td>IEC 60076-11<\/td>\n<td>F\/H \ud074\ub798\uc2a4 \ud55c\uacc4 \ub0b4\uc5d0\uc11c\uc758 \uad8c\uc120 \uc0c1\uc2b9<\/td>\n<\/tr>\n<tr>\n<td>\uc815\uae30 \ud14c\uc2a4\ud2b8<\/td>\n<td>IEC 60076-11<\/td>\n<td>\ube44\uc728, \uc800\ud56d, \uc190\uc2e4\uc774 \ud5c8\uc6a9 \uc624\ucc28 \ub0b4\uc5d0 \uc788\uc74c<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\ubcc0\uc555\uae30\ub97c \uc218\ucd9c\ud558\ub294 \ud68c\uc0ac\uc5d0 \uac00\uc7a5 \uc911\uc694\ud55c \uc778\uc99d\uc11c\ub294 \uc81c\uc870 \uc911\uc778 \uc815\uaca9 \uacc4\uc5f4\uc758 \uc720\ud615 \uc2dc\ud5d8 \uacb0\uacfc\uc640 \uc774 \ud2b9\uc815 \ubcc0\uc555\uae30\uc758 \uc815\uae30 \uc2dc\ud5d8 \ubcf4\uace0\uc11c\uc785\ub2c8\ub2e4. Subian\uc740 \uac01 \uc720\ub2db\uc5d0 \ub300\ud574 \uc218\ud589\ub41c \uc2dc\ud5d8\uc758 \uc644\uc804\ud55c \uae30\ub85d\uacfc \ud568\uaed8 \uc774 \ub450 \uac00\uc9c0\ub97c \uc81c\uacf5\ud569\ub2c8\ub2e4. \uc774 \ubb38\uc11c\ub294 \uacf5\uc7a5\uc744 \ubc29\ubb38\ud558\uc9c0 \uc54a\uace0\ub3c4 \uc911\uad6d \uc0dd\uc0b0\uc790\uc758 \uc6b4\uc601\uc744 \uc2b9\uc778\ud560 \uc218 \uc788\uac8c \ud569\ub2c8\ub2e4.<\/p>\n<h2 id=\"market\">\uc2dc\uc7a5 \ubc1c\uc804: \uc9c0\uc5ed \uacf5\uae09\uc5c5\uccb4\uc5d0\uc11c \uc218\ucd9c \uacf5\uae09\uc5c5\uccb4\ub85c<\/h2>\n<p>\uc2dc\uc7a5\uc758 \uad6c\uc870\uc801 \ubcc0\ud654\ub294 \ud2b9\uc815 \uc694\uc778 \ub355\ubd84\uc5d0 Subian\uc758 \uc131\uacf5\uc744 \uac00\uc838\uc624\uace0 \uc788\uc2b5\ub2c8\ub2e4. \ubc30\uc804 \ubcc0\uc555\uae30\uc5d0 \ub300\ud55c \uae00\ub85c\ubc8c \uc218\uc694\ub294 \uadf8\ub9ac\ub4dc \uac31\uc2e0, \ub3c4\uc2dc\ud654 \ubc0f \uc7ac\uc0dd \uac00\ub2a5 \uc5d0\ub108\uc9c0 \ud1b5\ud569\uc758 \uc601\ud5a5\uc744 \ubc1b\uc2b5\ub2c8\ub2e4. \uc11c\uad6c \uc81c\uc870\uc5c5\uccb4\ub4e4\uc774 \uc218\ub144 \uac04\uc758 \ub300\uae30 \ubaa9\ub85d\uc73c\ub85c \uc5b4\ub824\uc6c0\uc744 \uacaa\uace0 \uc788\ub294 \ubc18\uba74, \uc774\uc804\uc5d0 \uc911\uad6d \uacf5\uae09\uc5c5\uccb4\uc640 \ud611\ub825\ud560 \uc0dd\uac01\uc870\ucc28 \ud558\uc9c0 \uc54a\uc558\ub358 \uad6c\ub9e4\uc790\ub4e4\uc740 \uc801\uadf9\uc801\uc73c\ub85c \uac70\ub798\ub97c \ucc3e\uace0 \uc788\uc2b5\ub2c8\ub2e4. \uc774\uc81c \uc218\uc6a9\uc758 \uae30\uc900\uc740 \uae30\uc220 \uc778\uc99d \ubc0f \uc2dc\ud5d8 \uc678\uc5d0\ub3c4 \ubc30\uc1a1\uc758 \uc2e0\ub8b0\uc131\uc744 \ud3ec\ud568\ud558\uc5ec \uc0c1\ub2f9\ud788 \ub192\uc544\uc84c\uc2b5\ub2c8\ub2e4.<\/p>\n<p>Subian\uc740 \uac00\uaca9\uc774 \uc544\ub2cc \ud2b9\uc815 \ubb38\uc11c\uc640 \uc2e0\ub8b0\uc131\uc73c\ub85c \uacbd\uc7c1\ud558\uae30\ub85c \uacb0\uc815\ud588\uc2b5\ub2c8\ub2e4. \uc774\uc81c \uc218\ucd9c \uc120\uc801\uc5d0\ub294 IEC 60076-11 \uc2dc\ud5d8 \uc778\uc99d\uc11c, \uc720\ub2db\ub2f9 \uc218\ud589\ub41c \uc2dc\ud5d8\uc5d0 \ub300\ud55c \uc815\uae30 \ubcf4\uace0\uc11c, \uc124\uce58 \ub9e4\ub274\uc5bc \ubc0f \uccad\uc0ac\uc9c4\uc774 \ud3ec\ud568\ub418\ub294 \uac83\uc774 \uc77c\ubc18\uc801\uc785\ub2c8\ub2e4. \ud45c\uc900 \uc6a9\ub7c9\uc758 \ubc30\uc1a1 \uc2dc\uac04\uc740 25-45\uc77c\ub85c, \uc77c\ubd80 \uc11c\uad6c \ube0c\ub79c\ub4dc\uc758 6-12\uac1c\uc6d4\uc5d0 \ube44\ud574 \ud6e8\uc52c \uc9e7\uc2b5\ub2c8\ub2e4.<\/p>\n<h2 id=\"pricing\">\uc774 \uc720\ub2db\uc758 \ube44\uc6a9: \uac00\uaca9 \ubc0f \uac00\uce58<\/h2>\n<p>\ub4dc\ub77c\uc774 \ud0c0\uc785 \uae30\uc220\uc758 \uac00\uaca9\uc740 \uc815\uaca9 \ud074\ub798\uc2a4, \uc804\uc555 \ud074\ub798\uc2a4, \uc808\uc5f0 \ud074\ub798\uc2a4 \ubc0f \ucf54\uc5b4 \ud074\ub798\uc2a4\uc5d0 \ub530\ub77c \ub2ec\ub77c\uc9d1\ub2c8\ub2e4. Subian SCB \uc8fc\uc870 \uc218\uc9c0 \uc720\ub2db\uc5d0 \ub300\ud55c \uc81c\uacf5\ub41c \uc9c0\ud45c FOB \uc694\uae08\uc740 \ucd5c\uc885 \uac00\uaca9\uc774 \uc0ac\uc591, \ube0c\ub79c\ub4dc \ubc0f \uc720\ub2db\uc758 \uc9c0\uc5ed\uacfc \uac19\uc740 \uc694\uc778\uc5d0 \ub530\ub77c \ub2ec\ub77c\uc9c0\uae30 \ub54c\ubb38\uc5d0 \uc88b\uc740 \uae30\uc900\uc810\uc744 \uc81c\uacf5\ud574\uc57c \ud569\ub2c8\ub2e4.<\/p>\n<table>\n<thead>\n<tr>\n<th>\ub4f1\uae09<\/th>\n<th>\uc9c0\ud45c FOB \ubc94\uc704 (10 kV \ud074\ub798\uc2a4)<\/th>\n<th>\ube44\uace0<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>100 kVA<\/td>\n<td>$3,000\u2013$6,000<\/td>\n<td>F \ud074\ub798\uc2a4, \uc8fc\uc870 \uc218\uc9c0<\/td>\n<\/tr>\n<tr>\n<td>250 kVA<\/td>\n<td>$6,500\u2013$11,000<\/td>\n<td>H \ud074\ub798\uc2a4\ub294 \uc57d 10%\ub97c \ucd94\uac00\ud569\ub2c8\ub2e4.<\/td>\n<\/tr>\n<tr>\n<td>400 kVA<\/td>\n<td>$9,000\u2013$16,000<\/td>\n<td>\uac00\uc7a5 \uc77c\ubc18\uc801\uc778 \uc0b0\uc5c5 \ud06c\uae30<\/td>\n<\/tr>\n<tr>\n<td>630 kVA<\/td>\n<td>$13,000\u2013$22,000<\/td>\n<td>35 kV \ud074\ub798\uc2a4\ub294 \uc57d ~15% \ucd94\uac00<\/td>\n<\/tr>\n<tr>\n<td>1,000 kVA<\/td>\n<td>$20,000\u2013$38,000<\/td>\n<td>\ube44\uc815\uc9c8 \ucf54\uc5b4\uac00 \uc0c1\uc704\ub85c \ubc00\uc5b4\ub0c5\ub2c8\ub2e4.<\/td>\n<\/tr>\n<tr>\n<td>2,500 kVA<\/td>\n<td>$45,000\u2013$85,000<\/td>\n<td>\ub300\ud615 \uc0b0\uc5c5 \/ \uc720\ud2f8\ub9ac\ud2f0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\uc720\uc0ac\ud55c \uc0ac\uc591\uc744 \uac00\uc9c4 \uc774 \ud56d\ubaa9\ub4e4\uc758 \uac00\uaca9\uc740 \uc77c\ubc18\uc801\uc73c\ub85c ABB, Siemens \ub610\ub294 Schneider\uc758 \uc720\uc0ac\ud55c \uc8fc\uc870 \uc218\uc9c0 \uc720\ub2db\ubcf4\ub2e4 25-40% \ub0ae\uc740 \ubc94\uc704\uc5d0 \uc788\uc2b5\ub2c8\ub2e4 \u2014 \ud504\ub9ac\ubbf8\uc5c4\uc744 \ubd80\uacfc\ud558\ub294 \uc778\uc9c0 \uac00\ub2a5\ud55c \ube0c\ub79c\ub4dc\ub4e4\uc785\ub2c8\ub2e4.<\/p>\n<h2 id=\"comparison\">Subian\uc774 \uae30\uc874 \ube0c\ub79c\ub4dc\uc640 \ube44\uad50\ub418\ub294 \ubc29\ubc95<\/h2>\n<table>\n<thead>\n<tr>\n<th>\ube0c\ub79c\ub4dc<\/th>\n<th>\uc8fc\uc870 \uc218\uc9c0 \ubc94\uc704<\/th>\n<th>\uac00\uaca9 \ud3ec\uc9c0\uc158<\/th>\n<th>\ub9ac\ub4dc \ud0c0\uc784<\/th>\n<th>\ubb38\uc11c<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>ABB<\/td>\n<td>\ucd5c\ub300 63 MVA<\/td>\n<td>\ud504\ub9ac\ubbf8\uc5c4<\/td>\n<td>6\u201318\uac1c\uc6d4<\/td>\n<td>\ud3ec\uad04\uc801<\/td>\n<\/tr>\n<tr>\n<td>\uc9c0\uba58\uc2a4 (GEAFOL)<\/td>\n<td>\ucd5c\ub300 40 MVA<\/td>\n<td>\ud504\ub9ac\ubbf8\uc5c4<\/td>\n<td>6\u201318\uac1c\uc6d4<\/td>\n<td>\ud3ec\uad04\uc801<\/td>\n<\/tr>\n<tr>\n<td>\uc288\ub098\uc774\ub354 (Trihal)<\/td>\n<td>\ucd5c\ub300 16 MVA<\/td>\n<td>\ud504\ub9ac\ubbf8\uc5c4<\/td>\n<td>4\u201312\uac1c\uc6d4<\/td>\n<td>\ud3ec\uad04\uc801<\/td>\n<\/tr>\n<tr>\n<td>\ud788\ud0c0\uce58 \uc5d0\ub108\uc9c0<\/td>\n<td>Resibloc \ube14\ub85d<\/td>\n<td>\ud504\ub9ac\ubbf8\uc5c4<\/td>\n<td>6\u201318\uac1c\uc6d4<\/td>\n<td>\ud3ec\uad04\uc801<\/td>\n<\/tr>\n<tr>\n<td>\uc7a5\uc464 \uc218\ube44\uc548<\/td>\n<td>\ucd5c\ub300 10 MVA<\/td>\n<td>\uac00\uce58 (25\u201340% \ub0ae\uc74c)<\/td>\n<td>25\u201345\uc77c<\/td>\n<td>IEC \uc720\ud615 + \ub8e8\ud2f4 \ubcf4\uace0\uc11c<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>ABB, Siemens, Schneider Electric \ubc0f Hitachi Energy\uc640 \uac19\uc740 \uae00\ub85c\ubc8c \uae30\uc5c5\ub4e4\uc740 \uc8fc\uc870 \uc218\uc9c0 \uc138\uadf8\uba3c\ud2b8\ub97c \uc120\ub3c4\ud588\uc73c\uba70, \uadf8\ub4e4\uc758 \uc720\ud615 \uc2dc\ud5d8 \ud3ec\ud2b8\ud3f4\ub9ac\uc624\uc640 \uc11c\ube44\uc2a4 \ub124\ud2b8\uc6cc\ud06c\ub294 \uc885\uc885 \ubcf5\uc81c\ud558\uae30 \ubd88\uac00\ub2a5\ud569\ub2c8\ub2e4. \uadf8\ub7ec\ub098 \uc911\uac04 \uaddc\ubaa8 \ud504\ub85c\uc81d\ud2b8\uac00 \ud544\uc694\ub85c \ud558\uc9c0 \uc54a\ub294 \uac83\uc740 \uc804\uccb4 \uc0dd\ud0dc\uacc4\uc785\ub2c8\ub2e4 \u2014 \uc624\ud788\ub824 IEC 60076-11\uc744 \uc900\uc218\ud558\uace0 \ubb38\uc11c\ud654\uac00 \ub418\uc5b4 \uc788\uc73c\uba70 \uc801\uc2dc \ubc30\uc1a1\uc744 \ubcf4\uc7a5\ud558\ub294 \uc778\uc99d\ub41c \uc720\ub2db\uc774 \ud544\uc694\ud569\ub2c8\ub2e4. \uc7a5\uc464 \uc218\ube44\uc548 \uc804\ub825\uc758 \ubc1c\uc804\uc740 \ubc14\ub85c \uadf8 \uaca9\ucc28, \uc989 IEC\uc5d0 \ub530\ub77c \ucd5c\ub300 10 MVA\uc758 \ub4dc\ub77c\uc774 \ud0c0\uc785 \ubcc0\uc555\uae30\ub97c \uc644\uc804\ud55c \ubb38\uc11c\uc640 \ud569\ub9ac\uc801\uc778 \uc870\uac74\uc73c\ub85c \uc0dd\uc0b0\ud558\ub294 \ub370 \uae30\ubc18\ud558\uace0 \uc788\uc2b5\ub2c8\ub2e4.<\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-10747\" src=\"https:\/\/subian-electric.com\/wp-content\/uploads\/2026\/08\/How-to-Verify-a-Manufacturers-Claims.webp\" alt=\"\uc81c\uc870\uc5c5\uccb4\uc758 \uc8fc\uc7a5\uc744 \uac80\uc99d\ud558\ub294 \ubc29\ubc95\" width=\"1448\" height=\"1086\" \/><\/p>\n<h2 id=\"evaluate\">\uc81c\uc870\uc5c5\uccb4\uc758 \uc8fc\uc7a5 \ud655\uc778 \ubc29\ubc95<\/h2>\n<ul>\n<li>\uc694\uad6c\ub418\ub294 \uc815\uaca9 \uacc4\uc5f4\uc5d0 \ub300\ud574 \ubc1c\uae09\ub41c \uc815\ud655\ud55c \uc720\ud615 \uc2dc\ud5d8 \uc778\uc99d\uc11c\ub97c \uc694\uad6c\ud558\ub294 \uac83\uc774 \ubc14\ub78c\uc9c1\ud569\ub2c8\ub2e4. \ub2e4\ub978 \ud06c\uae30\uc5d0 \ub300\ud55c \uc77c\ubc18 \uc778\uc99d\uc11c\ub97c \ubc1b\ub294 \uac83\ub9cc\uc73c\ub85c\ub294 \uacb0\uacfc\ub97c \uac00\uc838\uc624\uc9c0 \uc54a\uc2b5\ub2c8\ub2e4. \ub2e8\uc704\ub2f9 \uc81c\uacf5\ub41c \uc911\ub7c9 \uc22b\uc790\uac00 \uae30\uc7ac\ub41c \ud45c\uc900 \uc2dc\ud5d8 \ubcf4\uace0\uc11c \uc0d8\ud50c\uc744 \uc694\uccad\ud558\uc2ed\uc2dc\uc624.<\/li>\n<li>\uc8fc\uc5b4\uc9c4 \ud45c\uc900\uc5d0 \ub530\ub77c \uc8fc\uc785 \uc218\uc9c0\uc5d0 \ub300\ud55c \uc0b0\uc5c5\uc5d0\uc11c \uc124\uc815\ud55c \uae30\uc900\uc774 1.1 \u00d7 \uc815\uaca9 \uc804\uc555\uc5d0 \ub300\ud574 10 pC \ubbf8\ub9cc\uc784\uc744 \ud655\uc778\ud558\uc2ed\uc2dc\uc624.<\/li>\n<li>\ud655\uc778\ub41c \uc808\uc5f0 \ub4f1\uae09(F=100 k, H=125 k)\uc774 \uc801\uc6a9 \uc628\ub3c4 \ud55c\uacc4\uc5d0 \ud574\ub2f9\ud558\ub294\uc9c0 \ud655\uc778\ud558\uc2ed\uc2dc\uc624.<\/li>\n<li>\uacb0\uc81c\ud558\uae30 \uc804\uc5d0 \uc81c\uacf5\ub41c \uce58\uc218 \ubc0f \uae30\ucd08 \ub3c4\uba74\uc774 \uadc0\ud558\uc758 \uc2a4\uc704\uce58\ub8f8\uc5d0 \uc801\ud569\ud55c\uc9c0 \ud655\uc778\ud558\uc2ed\uc2dc\uc624.<\/li>\n<li>\uccab \uc8fc\ubb38\uc5d0 \ub300\ud574 \uacf5\uc7a5 \uac10\uc0ac \ub610\ub294 \uc81c3\uc790 \uac80\uc0ac\ub97c \uc694\uccad\ud558\uc2ed\uc2dc\uc624(\uc608: SGS, T\u00dcV).<\/li>\n<li>\uadc0\ud558\uc758 \uc9c0\uc5ed\uc73c\ub85c\uc758 \ucc38\uc870 \uc120\uc801 \ubc0f \uc811\uadfc \uac00\ub2a5\ud55c \uace0\uac1d \uc5f0\ub77d\ucc98\ub97c \uc694\uccad\ud558\uc2ed\uc2dc\uc624.<\/li>\n<\/ul>\n<h2 id=\"faq\">\uc790\uc8fc \ubb3b\ub294 \uc9c8\ubb38<\/h2>\n<h3>Jiangsu Subian Power\ub294 \uc5b4\ub5a4 \uac74\uc2dd \ubcc0\uc555\uae30 \uc815\uaca9\uc744 \uc81c\uacf5\ud569\ub2c8\uae4c?<\/h3>\n<p>\uc774 \ud68c\uc0ac\ub294 10kV, 20kV \ubc0f 35kV \uc804\uc555 \ud074\ub798\uc2a4\uc5d0\uc11c 30kVA\uc5d0\uc11c 10,000kVA\uae4c\uc9c0\uc758 \ubcc0\uc555\uae30\ub97c \uc0dd\uc0b0\ud558\uba70, \uc8fc\uc785 \uc218\uc9c0 \ubc0f VPI \uc808\uc5f0 \uae30\uc220\uc744 \uc0ac\uc6a9\ud558\uace0 \uc788\uc73c\uba70, IEC 60076-11 \ud45c\uc900\uc5d0 \ub530\ub77c F \ubc0f H \uc808\uc5f0 \ud074\ub798\uc2a4 \uc635\uc158\ub3c4 \uc81c\uacf5\ud569\ub2c8\ub2e4. \uc774 \ud68c\uc0ac\ub294 \ub610\ud55c 100-2,500 kVA \ubc94\uc704\uc758 \uc624\uc77c \ucf54\uc5b4 \ubcc0\uc555\uae30\ub3c4 \uc81c\uacf5\ud569\ub2c8\ub2e4.<\/p>\n<h3>Jiangsu Subian\uc758 \uac74\uc2dd \ubcc0\uc555\uae30\ub294 IEC \uc778\uc99d\uc744 \ubc1b\uc558\uc2b5\ub2c8\uae4c?<\/h3>\n<p>\uc608, \uc774 \ud68c\uc0ac\ub294 IEC 60076-11 \uaddc\uc815\uc744 \uc900\uc218\ud558\uc5ec \uac74\uc2dd \ubcc0\uc555\uae30\ub97c \uc124\uacc4\ud569\ub2c8\ub2e4. \ucd5c\uc2e0 \uc124\uacc4\ub294 \uc778\uc99d\uc744 \ubc1b\uc558\uc73c\uba70 \uc2dc\ud5d8 \uacb0\uacfc\ub294 \ud544\uc218\uc801\uc785\ub2c8\ub2e4.<\/p>\n<h3>Subian\uc758 \uac74\uc2dd \ubcc0\uc555\uae30\ub294 ABB \ub610\ub294 Siemens\uc640 \ube44\uad50\ud558\uc5ec \uc5bc\ub9c8\ub098 \ube44\uc6a9\uc774 \ub4ed\ub2c8\uae4c?<\/h3>\n<p>Subian\uc758 \uac00\uaca9\uc740 ABB, Siemens \ubc0f Schneider\uc758 \uac74\uc2dd \ubcc0\uc555\uae30\uc640 \ube44\uad50\ud558\uc5ec \ud6e8\uc52c \ub0ae\uc73c\uba70, 25%\uc5d0\uc11c 40%\uae4c\uc9c0\uc785\ub2c8\ub2e4. \uc608\ub97c \ub4e4\uc5b4, 1,000kVA \uc8fc\uc785 \uc218\uc9c0 \ubcc0\uc555\uae30\ub294 $20,000\uc5d0\uc11c $38,000 \uc0ac\uc774\uc758 \uac00\uaca9\uc73c\ub85c \uc81c\uacf5\ub418\uba70, \ud504\ub9ac\ubbf8\uc5c4 \uc11c\uc591 \uc81c\uc870\uc5c5\uccb4\uc758 \uacbd\uc6b0 $35,000\uc5d0\uc11c $60,000 \uc0ac\uc774\uc785\ub2c8\ub2e4.<\/p>\n<h3>Subian\uc758 \uac74\uc2dd \ubcc0\uc555\uae30\uc5d0 \ub300\ud55c \uc77c\ubc18\uc801\uc778 \ubc30\uc1a1 \uc2dc\uac04\uc740 \uc5bc\ub9c8\uc785\ub2c8\uae4c?<\/h3>\n<p>Jiangsu Subian\uc740 \uc8fc\ubb38 \ud655\uc778 \ud6c4 100kVA\uc5d0\uc11c 2,500kVA\uae4c\uc9c0\uc758 \ud45c\uc900 \uac74\uc2dd \ubcc0\uc555\uae30\ub97c \ubc30\uc1a1\ud558\ub294 \ub370 \uc57d 25\uc77c\uc5d0\uc11c 45\uc77c\uc774 \uac78\ub9bd\ub2c8\ub2e4. \ub300\ud615 \ubcc0\uc555\uae30\uc758 \uc81c\uc870 \uacfc\uc815\uacfc \uc720\ud615 \uc2dc\ud5d8\uc740 \ucd5c\ub300 60\uc77c\uc5d0\uc11c 90\uc77c\uc774 \uac78\ub9b4 \uc218 \uc788\uc73c\uba70, \uc774\ub294 \uc11c\uc591\uc5d0\uc11c\uc758 6\uac1c\uc6d4\uc5d0\uc11c 18\uac1c\uc6d4\uc758 \ub300\uae30 \uae30\uac04\ubcf4\ub2e4 \ud6e8\uc52c \ub098\uc740 \uac83\uc785\ub2c8\ub2e4.<\/p>\n<h3>Subian\uc740 \uc624\uc77c \uce68\uc9c0 \ubcc0\uc555\uae30\ub3c4 \uc81c\uc870\ud569\ub2c8\uae4c?<\/h3>\n<p>Jiangsu Subian\uc740 10kV\uc5d0\uc11c 110kV \ubc94\uc704\uc5d0\uc11c \uc6b4\uc601\ud558\ub294 \uace0\uac1d\uc744 \uc704\ud574 \uc624\uc77c \uce68\uc9c0 \ubc30\uc804 \ubc0f \uc804\ub825 \ubcc0\uc555\uae30\ub97c \uc81c\uc870\ud558\uc5ec, \uace0\uac1d\uc774 \ud55c \uacf5\uae09\uc5c5\uccb4\ub85c\ubd80\ud130 \uac74\uc2dd \ubc0f \uc624\uc77c \uce68\uc9c0 \ubcc0\uc555\uae30\ub97c \ubaa8\ub450 \uc870\ub2ec\ud560 \uc218 \uc788\ub3c4\ub85d \ud558\uc5ec \uc2dc\uac04\uacfc \uc6b4\uc601 \ube44\uc6a9\uc744 \uc808\uac10\ud560 \uc218 \uc788\uc2b5\ub2c8\ub2e4.<\/p>\n<h2 id=\"references\">\ucc38\uace0 \ubb38\ud5cc<\/h2>\n<ul>\n<li><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/63660\" rel=\"nofollow noopener\" target=\"_blank\">IEC 60076-11: \uac74\uc2dd \uc804\ub825 \ubcc0\uc555\uae30<\/a> \u2014 \uac74\uc2dd \ubcc0\uc555\uae30 \uc808\uc5f0 \ud074\ub798\uc2a4, \uc2dc\ud5d8 \ubc0f \uc815\uaca9\uc744 \uaddc\uc815\ud558\ub294 \uad6d\uc81c \ud45c\uc900\uc785\ub2c8\ub2e4.<\/li>\n<li><a href=\"https:\/\/www.ieee.org\/\" rel=\"nofollow noopener\" target=\"_blank\">IEEE<\/a> \u2014 \ubcc0\uc555\uae30 \uc5d4\uc9c0\ub2c8\uc5b4\ub9c1 \ubc0f \uc2dc\ud5d8\uc744 \uc704\ud574 IEC\uc640 \ud568\uaed8 \uc0ac\uc6a9\ub418\ub294 IEEE C57 \ud45c\uc900\uc758 \ubc1c\ud589\uc790\uc785\ub2c8\ub2e4.<\/li>\n<li><a href=\"https:\/\/www.nfpa.org\/codes-and-standards\/all-codes-and-standards\/list-of-codes-and-standards\/detail?code=70\" rel=\"nofollow noopener\" target=\"_blank\">NFPA 70 (\uad6d\uac00 \uc804\uae30 \ucf54\ub4dc)<\/a> \u2014 \uac74\uc2dd \ubcc0\uc555\uae30\ub97c \uae08\uace0 \uc5c6\uc774 \uc124\uce58\ud560 \uc218 \uc788\ub294 \uc704\uce58\ub97c \uc815\uc758\ud558\ub294 \ucf54\ub4dc\uc785\ub2c8\ub2e4.<\/li>\n<li><a href=\"https:\/\/www.nema.org\/\" rel=\"nofollow noopener\" target=\"_blank\">NEMA<\/a> \u2014 \ubcc0\uc555\uae30 \ud6a8\uc728\uc131\uacfc \uc778\ud074\ub85c\uc800\uc5d0 \ub300\ud55c \ubd81\ubbf8 \ud45c\uc900 \uae30\uad00\uc785\ub2c8\ub2e4.<\/li>\n<li><a href=\"https:\/\/www.energy.gov\/eere\/femp\/energy-conservation-program-standards-distribution-transformers\" rel=\"nofollow noopener\" target=\"_blank\">\ubbf8\uad6d DOE \ubc30\uae09 \ubcc0\uc555\uae30 \ud45c\uc900<\/a> \u2014 \uc804 \uc138\uacc4\uc801\uc73c\ub85c \uac74\uc2dd \ubcc0\uc555\uae30 \uc218\uc694\ub97c \ud615\uc131\ud558\ub294 \ud6a8\uc728\uc131 \uaddc\uc815\uc785\ub2c8\ub2e4.<\/li>\n<li><a href=\"https:\/\/subian-electric.com\/ko\/\">\uc7a5\uc464 \uc218\ube44\uc548 \uc804\ub825 \uc720\ud55c\ud68c\uc0ac.<\/a> \u2014 \ub4dc\ub77c\uc774 \ud0c0\uc785 \ubc0f \uc624\uc77c \uce68\uc9c0 \ubcc0\uc555\uae30 \uc81c\ud488 \uc815\ubcf4\uac00 \ud3ec\ud568\ub41c \uacf5\uc2dd \uc81c\uc870\uc5c5\uccb4 \uc0ac\uc774\ud2b8\uc785\ub2c8\ub2e4.<\/li>\n<\/ul>\n<h2 id=\"conclusion\">\uacb0\ub860<\/h2>\n<p>\ub4dc\ub77c\uc774 \ud0c0\uc785 \ubcc0\uc555\uae30\uc5d0\uc11c \uc7a5\uc464 \uc218\ube44\uc548 \uc804\ub825\uc758 \ubc1c\uc804\uc740 \uc18c\ube44\uc790\uc5d0\uac8c \uc911\uc694\ud55c \ubc29\uc2dd\uc73c\ub85c \uce21\uc815\ub420 \uc218 \uc788\uc2b5\ub2c8\ub2e4. \ud68c\uc0ac\uc758 \uc131\uacfc\ub294 \ub2e4\uc74c\uacfc \uac19\uc774 \ub098\uc5f4\ub420 \uc218 \uc788\uc2b5\ub2c8\ub2e4: \ud68c\uc0ac\ub294 \uc815\uaca9\uc744 10,000 kVA\ub85c \ud655\uc7a5\ud558\uace0, \uc774\uc911 \uc8fc\uc870 \uc218\uc9c0 \ubc0f VPI \uae30\uc220\uc744 \uc0ac\uc6a9\ud558\uba70, IEC 60076-11\uc758 \uae30\uc900\uc744 \uc900\uc218\ud558\uace0 \ub3d9\ubc18\ub418\ub294 \ub2e8\uc704 \ud14c\uc2a4\ud2b8 \ubcf4\uace0\uc11c\ub97c \uc81c\uacf5\ud558\uba70, \uc218\ucd9c \ubc30\uc1a1 \uae30\uac04\uc740 25\uc77c\uc5d0\uc11c 45\uc77c \uc0ac\uc774\uc785\ub2c8\ub2e4. \uc218\ube44\uc548\uc758 \uac00\uce58 \uc81c\uc548\uc740 \ub9e4\uc6b0 \uac04\ub2e8\ud569\ub2c8\ub2e4: \ud68c\uc0ac\ub294 \uc720\uba85\ud55c \uc11c\uc591 \ube0c\ub79c\ub4dc\uc5d0\uc11c \uc0dd\uc0b0\ub41c \uc720\uc0ac \uc81c\ud488\ubcf4\ub2e4 25-40% \uc800\ub834\ud55c \uac00\uaca9\uc5d0 \uc88b\uc740 \ud488\uc9c8\uc758 \uc778\uc99d\ub41c \uc81c\ud488\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4. \ubaa8\ub378 \uc120\ud0dd\ub3c4 \ub9cc\uc871\uc2a4\ub7fd\uc2b5\ub2c8\ub2e4. \uc218\ube44\uc548\uc740 \ud558\ub098\uc758 \ud504\ub85c\uc81d\ud2b8\uc5d0\uc11c \ub2e8\uc77c \uc8fc\ubb38\uc73c\ub85c \uace0\uac1d\uc758 \uc694\uad6c\ub97c \ucda9\uc871\ud560 \uc218 \uc788\uc2b5\ub2c8\ub2e4. \uadc0\ud558\uc758 \uc694\uad6c\ub97c \ucda9\uc871\ud560 \uacf5\uae09\uc5c5\uccb4\ub97c \ucc3e\uace0 \uc2f6\ub2e4\uba74, \uadf8\ub4e4\uc5d0\uac8c \uc720\ud615 \ud14c\uc2a4\ud2b8 \ubcf4\uace0\uc11c\ub97c \uc694\uccad\ud558\uace0, \uc774\uc0c1\uc801\uc73c\ub85c\ub294 \uba87 \uac00\uc9c0 \ub2e4\ub978 \ud14c\uc2a4\ud2b8 \ubcf4\uace0\uc11c\uc640 \uadc0\ud558\uc758 \ud504\ub85c\uc81d\ud2b8\uc5d0 \ub300\ud55c \uc0c1\uc138\ud55c \uac00\uaca9 \uc81c\uc548\uc744 \uc694\uccad\ud574\uc57c \ud569\ub2c8\ub2e4.<\/p>","protected":false},"excerpt":{"rendered":"<p>In the winter season of 2024, a distribution utility in Southeast Asia conducted replacement of a fire-damaged oil-immersed transformer inside a small urban substation by a dry-type transformer of 1,000 kVA that was manufactured by the supplier that had been vetted by the utility for a period extending two years in a silent manner. A [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":10745,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[77],"tags":[],"class_list":["post-10744","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/subian-electric.com\/ko\/wp-json\/wp\/v2\/posts\/10744","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/subian-electric.com\/ko\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/subian-electric.com\/ko\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/subian-electric.com\/ko\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/subian-electric.com\/ko\/wp-json\/wp\/v2\/comments?post=10744"}],"version-history":[{"count":2,"href":"https:\/\/subian-electric.com\/ko\/wp-json\/wp\/v2\/posts\/10744\/revisions"}],"predecessor-version":[{"id":10982,"href":"https:\/\/subian-electric.com\/ko\/wp-json\/wp\/v2\/posts\/10744\/revisions\/10982"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/subian-electric.com\/ko\/wp-json\/wp\/v2\/media\/10745"}],"wp:attachment":[{"href":"https:\/\/subian-electric.com\/ko\/wp-json\/wp\/v2\/media?parent=10744"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/subian-electric.com\/ko\/wp-json\/wp\/v2\/categories?post=10744"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/subian-electric.com\/ko\/wp-json\/wp\/v2\/tags?post=10744"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}