{"id":11178,"date":"2026-08-30T17:43:17","date_gmt":"2026-08-30T09:43:17","guid":{"rendered":"https:\/\/q8bbzjnpm5.wpdns.site\/?p=11178"},"modified":"2026-08-30T17:47:35","modified_gmt":"2026-08-30T09:47:35","slug":"500-kva-transformer-weight","status":"publish","type":"post","link":"https:\/\/subian-electric.com\/ko\/blog\/500-kva-transformer-weight\/","title":{"rendered":"500 kVA \ubcc0\uc555\uae30 \uc911\ub7c9"},"content":{"rendered":"<p>500 kVA\ub85c \ud3c9\uac00\ub41c \ubcc0\uc555\uae30\uc758 \uc778\uc218\ub97c \uace0\ub824\ud560 \ub54c, \uace0\ub824\ud574\uc57c \ud560 \ud544\uc218 \uc694\uc18c \uc911 \ud558\ub098\ub294 \ubcc0\uc555\uae30\uc758 \ubb34\uac8c\uc785\ub2c8\ub2e4. \ubcc0\uc555\uae30\uc758 \ubb34\uac8c\ub294 \ud544\uc694\ud55c \uc6b4\uc1a1 \ucc28\ub7c9\uc758 \uc885\ub958, \ud06c\ub808\uc778 \uc0ac\uc591, \uae30\ucd08, \uc801\uc7ac \ubc0f \uacf5\uae30 \uac04\uaca9, \uadf8\ub9ac\uace0 \uc791\uc5c5\uc7a5 \uc811\uadfc\uc131\uc5d0 \uc601\ud5a5\uc744 \ubbf8\uce69\ub2c8\ub2e4. \uadf8\ub7ec\ub098 \ub450 \uacf5\uae09\uc5c5\uccb4\ub85c\ubd80\ud130 500 kVA \ubcc0\uc555\uae30\uc758 \ubb34\uac8c\ub97c \uc694\uccad\ud560 \ub54c, \uac01\uac01 1200 kg\uacfc 2500 kg\uc758 \ub450 \uac00\uc9c0 \ub2e4\ub978 \ubb34\uac8c\ub97c \ubc1b\uc744 \uc218 \uc788\uc2b5\ub2c8\ub2e4. \ub450 \ubb34\uac8c \ubaa8\ub450 \uc815\ud655\ud55c\uac00\uc694? \ub124, \ub450 \ubb34\uac8c \ubaa8\ub450 \uc815\ud655\ud569\ub2c8\ub2e4. \ubcc0\uc555\uae30\uc758 \ubb34\uac8c\ub294 \uc0ac\uc6a9\ub41c \uc81c\uc791 \uc720\ud615(\uc720\uc785\ud615 \ubc0f \uac74\uc2dd\ud615), \uad8c\uc120 \uc720\ud615(\uad6c\ub9ac \ub610\ub294 \uc54c\ub8e8\ubbf8\ub284), \ud6a8\uc728 \ub4f1\uae09, \uc804\uc555 \ubc0f \uc81c\uc870\uc5c5\uccb4\uc5d0 \ub530\ub77c \ub2ec\ub77c\uc9c8 \uc218 \uc788\uc2b5\ub2c8\ub2e4. \ubb34\uac8c \ucc28\uc774\ub294 \uc815\ud655\ud558\uba70 \ub530\ub77c\uc11c \uc798\ubabb\ub41c \uc778\uc6a9\uc774 \uc544\ub2d9\ub2c8\ub2e4.<\/p>\n<p>\uc774 \uae30\uc0ac\ub294 \ubcc0\uc555\uae30\uc5d0 \ub300\ud55c \uc774\uc0c1\uc801\uc778 \ubb34\uac8c\uc640 \uc790\uc8fc \uc81c\uae30\ub418\ub294 \uc9c8\ubb38\uc5d0 \ub300\ud55c \ub2f5\ubcc0\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4.<\/p>\n<blockquote><p>\uac04\ub2e8\ud55c \ub2f5\ubcc0: 500 kVA \ubcc0\uc555\uae30\ub294 \uac74\uc870\ud560 \ub54c 1.2-1.8 \ubbf8\ud130 \ud1a4, \uae30\ub984\uc774 \ucc44\uc6cc\uc9c8 \ub54c 1.8-2.5 \ubbf8\ud130 \ud1a4\uc758 \ubb34\uac8c\uac00 \ub098\uac11\ub2c8\ub2e4. 10 kV\/0.4 kV \ubcc0\uc555\uae30\uc758 \uce74\ud0c8\ub85c\uadf8 \uac12\uc740 \uc720\uc785\ud615 \ubcc0\uc555\uae30\uc758 \uacbd\uc6b0 \uc57d 1.8-2.0 \ud1a4(\uadf8 \uc911 \uc57d 0.30-0.50 \ud1a4\uc740 \uae30\ub984\uc73c\ub85c \uad6c\uc131\ub428)\uacfc \uac74\uc2dd \ubcc0\uc555\uae30\uc758 \uacbd\uc6b0 1.2-1.8 \ud1a4\uc785\ub2c8\ub2e4. \ubcc0\uc555\uae30\uc758 \uc2e4\uc81c \ubb34\uac8c\ub294 \uc11c\ub85c \ub2e4\ub97c \uc218 \uc788\uc2b5\ub2c8\ub2e4. \ubcc0\uc555\uae30\uc758 \uc815\ud655\ud55c \ubb34\uac8c\ub294 \uc81c\uc870\uc5c5\uccb4\uc758 \uc0ac\uc591\uc744 \ud655\uc778\ud558\uc2ed\uc2dc\uc624. \ub610\ud55c, 500 kVA \ubcc0\uc555\uae30\ub97c \uc774\ub3d9\ud558\uae30 \uc704\ud574\uc11c\ub294 \uc911\ub7c9\ubb3c \ub9ac\ud504\ud305 \uc7a5\ube44\uac00 \ud544\uc694\ud558\ub2e4\ub294 \uc810\uc744 \uc720\uc758\ud558\uc2ed\uc2dc\uc624. \ubcc0\uc555\uae30\uc758 \uae30\ucd08\ub97c \uad6c\ucd95\ud560 \ub54c, \ubcc0\uc555\uae30\uc758 \ubb34\uac8c\uc5d0 \ub300\ud574 \ub9ac\ud504\ud305 \uc7a5\ube44\uc758 \ubb34\uac8c\ub97c 1.5\ubc30\ub85c \uacc4\ud68d\ud558\uc2ed\uc2dc\uc624.<\/p><\/blockquote>\n<h2>\ud604\uc2e4\uc801\uc778 \ubb34\uac8c \ubc94\uc704<\/h2>\n<p>\uc911\uad6d\uc5d0\uc11c \uc0ac\uc6a9\ub418\ub294 \uae30\uc900 \ud45c\uc900(GB\/T \ud45c)\uacfc \uc81c\uc870\uc5c5\uccb4 \uce74\ud0c8\ub85c\uadf8 \ubc0f \uc678\uad6d \uacf5\uae09\uc5c5\uccb4\ub97c \uae30\ubc18\uc73c\ub85c, 500 kVA \ubcc0\uc555\uae30\ub294 \ub2e4\uc74c\uacfc \uac19\uc740 \uc0ac\uc591\uc744 \uac00\uc9c8 \uac83\uc73c\ub85c \uc608\uc0c1\ub429\ub2c8\ub2e4:<\/p>\n<table>\n<thead>\n<tr>\n<th>\uc720\ud615<\/th>\n<th>\uc77c\ubc18 \ucd1d \ubb34\uac8c<\/th>\n<th>\uae30\ub984 \ud3ec\ud568 (\uc720\uc785\ud615\uc77c \uacbd\uc6b0)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\uac74\uc2dd\ud615, \uc0bc\uc0c1 (\uc218\uc9c0 \uc8fc\uc785\ud615 \/ \ud1b5\ud48d\ud615)<\/td>\n<td>2-1.8 t (2,600-4,000 lbs)<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>\uc720\uc785\ud615, 10 kV\/0.4 kV \ud074\ub798\uc2a4 (\uc911\uad6d \ud45c\uc900)<\/td>\n<td>8-2.5 t (4,000-5,500 lbs)<\/td>\n<td>3-0.5 t \uae30\ub984<\/td>\n<\/tr>\n<tr>\n<td>\uc720\uc785\ud615, \uace0\uc804\uc555 \ud074\ub798\uc2a4 (\uc608: 35 kV 1\ucc28)<\/td>\n<td>2-3.0 t<\/td>\n<td>4-0.6 t \uae30\ub984<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\uad6c\uccb4\uc801\uc778 \uc608\ub294 \ub2e4\uc74c\uacfc \uac19\uc2b5\ub2c8\ub2e4. S11\/S13 \uc885\ub958\uc758 500 kVA \uc720\uc785\ud615 \ubcc0\uc555\uae30\ub294 \ucd1d \uc57d 1.8-2.0 \ud1a4\uc73c\ub85c \ucd94\uc815\ub418\uba70, \ucf54\uc5b4\uc640 \ucf54\uc77c\uc758 \uc791\ub3d9 \ubb34\uac8c\ub294 \uc57d 1.0-1.2 \ud1a4, \uae30\ub984\uc740 0.3-0.5 \ud1a4\uc785\ub2c8\ub2e4. 500 kVA \uac74\uc2dd \ubcc0\uc555\uae30 SCB\ub294 \uc911\uad6d\uc5d0\uc11c \uc5ec\ub7ec \uce74\ud0c8\ub85c\uadf8\ub97c \uc0ac\uc6a9\ud558\uc5ec \uc57d 1.7-2.0 \ud1a4\uc73c\ub85c \ubcf4\uace0\ub418\uba70, \uad6d\uc81c \uc2dc\uc7a5\uc5d0\uc11c\ub294 \uac74\uc2dd \ubcc0\uc555\uae30\uac00 1.2-1.4 \ud1a4\uc73c\ub85c \ubcf4\uace0\ub429\ub2c8\ub2e4.<\/p>\n<h2>\ubb34\uac8c \ucc28\uc774\ub97c \uc720\ubc1c\ud558\ub294 \uc694\uc778<\/h2>\n<p>500 kVA\ub85c \ud3c9\uac00\ub41c \ub450 \ubcc0\uc555\uae30 \uac04\uc758 \ubb34\uac8c \ucc28\uc774\ub294 \ub2e4\uc74c\uc758 \uc77c\uacf1 \uac00\uc9c0 \uc694\uc778\uc73c\ub85c \uc124\uba85\ub420 \uc218 \uc788\uc2b5\ub2c8\ub2e4:<\/p>\n<ul>\n<li>\ubcc0\uc555\uae30 \uc720\ud615: \uc624\uc77c \uae30\ubc18 \ubcc0\uc555\uae30\ub294 kVA \ub4f1\uae09\uc5d0 \ub530\ub77c \uac74\uc2dd \ubcc0\uc555\uae30\ubcf4\ub2e4 30-50% \ub354 \ubb34\uac81\uc2b5\ub2c8\ub2e4. \uc774 \ubb34\uac8c \ucc28\uc774\ub294 \ud0f1\ud06c, \uc624\uc77c(500 kVA \ubcc0\uc555\uae30\uc758 \uacbd\uc6b0 0.3-0.5 t) \ubc0f \ubc29\uc5f4\ud310\uc758 \ucd94\uac00 \uc9c8\ub7c9\uc5d0 \uae30\uc778\ud560 \uc218 \uc788\uc2b5\ub2c8\ub2e4.<\/li>\n<li>\uad8c\uc120 \uc720\ud615: \ub3d9\uc77c\ud55c kVA \ub4f1\uae09\uc5d0\uc11c \uad6c\ub9ac \uad8c\uc120\uc740 \uc54c\ub8e8\ubbf8\ub284 \uad8c\uc120\ubcf4\ub2e4 10-20% \ub354 \ubb34\uac81\uc2b5\ub2c8\ub2e4. \uc774\ub294 \uad6c\ub9ac \uad8c\uc120\uc774 \ub354 \ub098\uc740 \uc804\ub3c4\uc131\uc73c\ub85c \uc778\ud574 \uacf5\uac04\uc744 \ub35c \ucc28\uc9c0\ud558\ub354\ub77c\ub3c4 \ubc00\ub3c4\uac00 \ub354 \ub192\uae30 \ub54c\ubb38\uc785\ub2c8\ub2e4.<\/li>\n<li>\ubcc0\uc555\uae30\uc758 \ud6a8\uc728 \ub4f1\uae09: \uc5d0\ub108\uc9c0 \ud6a8\uc728\uc131\uc744 \uc704\ud574 \uc124\uacc4\ub41c \ubcc0\uc555\uae30(S13\/S20, DOE)\ub294 \ubb34\ubd80\ud558 \uc190\uc2e4\uc744 \uc904\uc774\uae30 \uc704\ud574 \ub354 \ub9ce\uc740 \ucf54\uc5b4 \uac15\ucca0\uc774 \ud544\uc694\ud558\uba70, \uc774\ub294 \ud45c\uc900 \ubcc0\uc555\uae30\uc640 \ube44\uad50\ud560 \ub54c 5-15%\uc758 \ubb34\uac8c \ubcc0\ud654\ub97c \ucd08\ub798\ud569\ub2c8\ub2e4.<\/li>\n<li>\uc804\uc555 \ub4f1\uae09 \ubc0f BIL: \uace0\uc804\uc555 \ud30c\uc190\uc744 \ubc29\uc9c0\ud558\uae30 \uc704\ud574, \ubd80\uc2f1, \uc808\uc5f0\uccb4 \uc124\uacc4 \ubc0f \uc778\ud074\ub85c\uc800\ub294 \uc0c1\ub2f9\ud55c \uce58\uc218\uc640 \uac15\ud55c \ubb34\uac8c\ub97c \uac00\uc838\uc57c \ud569\ub2c8\ub2e4.<\/li>\n<li>\uad6c\uc870 \uc720\ud615: \ud328\ub4dc \uc7a5\ucc29 \ubcc0\uc555\uae30\uc640 \ub2ec\ub9ac, \uac15\ucca0 \ub610\ub294 \uc2a4\ud14c\uc778\ub9ac\uc2a4 \uc2a4\ud2f8 \uc778\ud074\ub85c\uc800\uac00 \ud544\uc694\ud558\uba70(NEMA 3R\uc740 \ucd5c\ub300 10-15%\uc758 \ucd94\uac00 \ubb34\uac8c\ub97c \uc758\ubbf8\ud569\ub2c8\ub2e4).<\/li>\n<li>\ub0c9\uac01 \ubc29\ubc95: \ubc29\uc5f4\ud310 \ub610\ub294 \uac04\ub2e8\ud55c \ud0f1\ud06c \uc720\ud615\uc758 \ucc28\uc774, \uac15\uc81c \uacf5\uae30 \ub0c9\uac01 \uc2dc\uc2a4\ud15c \uc720\ubb34\uc5d0 \ub530\ub77c \ud0f1\ud06c\uc640 \ub0c9\uac01 \uc2dc\uc2a4\ud15c\uc758 \uc9c8\ub7c9\uc774 \ubcc0\uacbd\ub420 \uc218 \uc788\uc2b5\ub2c8\ub2e4.<\/li>\n<li>\uc81c\uc870\uc5c5\uccb4 \ubc0f \ud45c\uc900: \ub3d9\uc77c\ud55c \ub4f1\uae09\uc758 \uacbd\uc6b0 \ud68c\uc0ac\uc758 \ucca0\ud559\uacfc \ud45c\uc900\uc774 \ubcc0\uc555\uae30\uc758 \ubb34\uac8c\ub97c \uc218\ubc31 \ud0ac\ub85c\uadf8\ub7a8 \ubcc0\uacbd\ud560 \uc218 \uc788\uc2b5\ub2c8\ub2e4.<\/li>\n<\/ul>\n<h2>\ube60\ub978 \ucd94\uc815 \uacf5\uc2dd<\/h2>\n<p>\ub370\uc774\ud130 \uc2dc\ud2b8\uac00 \uc81c\uacf5\ub418\uae30 \uc804\uc5d0 \uae30\ucc28 \ubc88\ud638\uac00 \ud544\uc694\ud560 \uacbd\uc6b0, \uc77c\ubc18\uc801\uc778 \uc0bc\uc0c1 \uc7a5\uce58\uc5d0 \ub300\ud574 10-15%\uc758 \uc815\ud655\ub3c4\ub85c \uc81c\uc870 \uad00\ud589\uc5d0\uc11c \ub450 \uac00\uc9c0 \uacf5\uc2dd\uc744 \uc0ac\uc6a9\ud560 \uc218 \uc788\uc2b5\ub2c8\ub2e4. \ub2e4\uc74c \uacf5\uc2dd\uc740 \uac74\uc2dd \uc0bc\uc0c1 \uc7a5\uce58\uc758 \ub300\ub7b5\uc801\uc778 \ubb34\uac8c\ub97c \uc5bb\ub294 \ub370 \uc0ac\uc6a9\ud560 \uc218 \uc788\uc2b5\ub2c8\ub2e4:<\/p>\n<ul>\n<li>\uac74\uc2dd\ud615(\uc0bc\uc0c1): \ubb34\uac8c\ub294 \uc57d 42\uc5d0 kVA \uc804\ub825 \ucd9c\ub825\uc744 0.56\uc758 \uac70\ub4ed\uc81c\uacf1\uc73c\ub85c \uacf1\ud55c \uac12\uacfc \uac19\uc73c\uba70, \ub530\ub77c\uc11c 500 kVA \uc7a5\uce58\uc758 \uacbd\uc6b0 \uc57d 1,230 \ud30c\uc6b4\ub4dc(\ub610\ub294 0.56 \ud1a4)\uc785\ub2c8\ub2e4.<\/li>\n<li>\uc624\uc77c \uce68\uc9c0\ud615(\uc0bc\uc0c1): \uc7a5\uce58\uc758 \ubb34\uac8c\ub294 \uc57d 31.5\uc5d0 kVA \uc804\ub825 \ucd9c\ub825\uc744 0.71\uc758 \uac70\ub4ed\uc81c\uacf1\uc73c\ub85c \uacf1\ud55c \uac12\uacfc \uac19\uc73c\uba70, \ub530\ub77c\uc11c \uc624\uc77c \uce68\uc9c0\ud615\uc758 \uacbd\uc6b0 \uc57d 2,230 \ud30c\uc6b4\ub4dc\ub85c \uac00\uc815\ud560 \uc218 \uc788\uc73c\uba70 \uc774\ub294 1\ud1a4\uc73c\ub85c \ubcc0\ud658\ub420 \uc218 \uc788\uc2b5\ub2c8\ub2e4.<\/li>\n<\/ul>\n<p>\ub530\ub77c\uc11c \uc704\uc758 \uacf5\uc2dd\uc774 \uad6d\uc81c \uc218\uc900\uc5d0\uc11c \ub354 \uac00\ubcbc\uc6b4 \uc124\uacc4\ub97c \ubc18\uc601\ud558\ub294 \uac83\uc744 \uad00\ucc30\ud560 \uc218 \uc788\uc2b5\ub2c8\ub2e4. \uadf8\ub7ec\ub098 \uc911\uad6d \ud45c\uc900 10 kV \uc624\uc77c \uce68\uc9c0\ud615 \uc7a5\uce58\ub294 \ud0f1\ud06c \uc124\uacc4 \ubc0f \ub0c9\uac01 \uc2dc\uc2a4\ud15c\uc73c\ub85c \uc778\ud574 \ub354 \ubb34\uac81\uc2b5\ub2c8\ub2e4(500 kVA\uc758 \uacbd\uc6b0 \uc57d 1.8\ud1a4\uc5d0\uc11c 2\ud1a4). \ub530\ub77c\uc11c \uc704\uc758 \uacf5\uc2dd\uc740 \uacc4\ud68d \ubc0f \uc608\uc0b0 \uc218\ub9bd\uc5d0 \ud65c\uc6a9\ub420 \uc218 \uc788\uc73c\uba70, \uc801\uc808\ud55c \ub370\uc774\ud130 \uc2dc\ud2b8\ub97c \ucc38\uc870\ud574\uc57c \ud569\ub2c8\ub2e4. <a href=\"\/ko\/blog\/transformer-specifications-explained\/\">\ubcc0\uc555\uae30 \uc0ac\uc591 \uac00\uc774\ub4dc<\/a> \ub370\uc774\ud130 \uc2dc\ud2b8\ub97c \uc77d\ub294 \ubc29\ubc95\uc744 \uc124\uba85\ud558\ubbc0\ub85c \ubb34\uac8c \uc218\uce58\ub294 \uc2e4\uc81c\ub85c \uc2e0\ub8b0\ud560 \uc218 \uc788\ub294 \uc218\uce58\uc785\ub2c8\ub2e4.<\/p>\n<h2>500 kVA \ub300 \uae30\ud0c0 \ub4f1\uae09: \ubb34\uac8c \ud45c<\/h2>\n<p>\ubb34\uac8c\ub294 \ub4f1\uae09\uc5d0 \ub530\ub77c \uae09\uaca9\ud788 \uc99d\uac00\ud558\uba70, \uc774 \ud328\ud134\uc740 \uc778\uc6a9\ub41c \uc22b\uc790\ub97c \uac80\uc99d\ud558\ub294 \ub370 \ub3c4\uc6c0\uc774 \ub429\ub2c8\ub2e4:<\/p>\n<table>\n<thead>\n<tr>\n<th>\ub4f1\uae09<\/th>\n<th>\uc624\uc77c \uce68\uc9c0\ud615(\uc804\ud615\uc801)<\/th>\n<th>\uac74\uc2dd\ud615(\uc804\ud615\uc801)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>100 kVA<\/td>\n<td>7-1.0 t (1,500-2,200 lbs)<\/td>\n<td>3-0.6 t (650-1,300 lbs)<\/td>\n<\/tr>\n<tr>\n<td>315 kVA<\/td>\n<td>3-1.7 t<\/td>\n<td>9-1.3 t<\/td>\n<\/tr>\n<tr>\n<td>500 kVA<\/td>\n<td>8-2.5 t (4,000-5,500 lbs)<\/td>\n<td>2-1.8 t (2,600-4,000 lbs)<\/td>\n<\/tr>\n<tr>\n<td>800 kVA<\/td>\n<td>5-3.2 t<\/td>\n<td>6-2.2 t<\/td>\n<\/tr>\n<tr>\n<td>1,000 kVA<\/td>\n<td>1-4.5 t (6,800-9,900 lbs)<\/td>\n<td>5-3.5 t<\/td>\n<\/tr>\n<tr>\n<td>2,000 kVA<\/td>\n<td>2-6.0 t<\/td>\n<td>0-5.5 t<\/td>\n<\/tr>\n<tr>\n<td>4,000 kVA<\/td>\n<td>~8.7 t<\/td>\n<td>~6.5-8 t<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\ub450 \uac00\uc9c0 \ud328\ud134\uc774 \ub450\ub4dc\ub7ec\uc9d1\ub2c8\ub2e4: \uc624\uc77c \uce68\uc9c0 \uc720\ub2db\uc740 \uc804\ubc18\uc801\uc73c\ub85c \ub4dc\ub77c\uc774 \ud0c0\uc785\ubcf4\ub2e4 30-50% \ub354 \ubb34\uac81\uc2b5\ub2c8\ub2e4 \u2014 \ucc28\uc774\ub294 \ud0f1\ud06c\uc640 \uc624\uc77c\uc5d0 \uc788\uc73c\uba70, \uc774\ub294 \uc6b0\ub9ac\uc758 <a href=\"\/ko\/product\/oil-immersed-transformer\/\">\uc624\uc77c \uce68\uc9c0 \ubcc0\uc555\uae30<\/a> \ud398\uc774\uc9c0\uc5d0 \uc790\uc138\ud788 \uc124\uba85\ub418\uc5b4 \uc788\uc73c\uba70, \ub4dc\ub77c\uc774 \ud0c0\uc785 \uc720\ub2db\uc758 \uc138\ubd80 \uc0ac\ud56d\uc740 \ub3d9\ubc18 \ub4dc\ub77c\uc774 \ud0c0\uc785 \ud398\uc774\uc9c0\uc5d0 \uc788\uc2b5\ub2c8\ub2e4 \u2014 \uadf8\ub9ac\uace0 500\uc5d0\uc11c 1,000 kVA\ub85c\uc758 \uc810\ud504\ub294 \uac70\uc758 \ubb34\uac8c\ub97c \ub450 \ubc30\ub85c \ub298\ub9ac\ubbc0\ub85c, \uc774 \ub450 \ub4f1\uae09 \uac04\uc758 \ud06c\ub808\uc778 \ubc0f \uae30\ucd08 \uacc4\ud68d\uc774 \ubcc0\uacbd\ub429\ub2c8\ub2e4.<\/p>\n<h2>\ubcc0\uc555\uae30\uc758 \uc815\ud655\ud55c \ubb34\uac8c\ub97c \ucc3e\ub294 \ubc29\ubc95<\/h2>\n<p>\uc774\ub984\ud310\uc5d0\uc11c \ucd1d \ubb34\uac8c\ub97c \ubc1b\uc9c0 \ubabb\ud558\ub294 \uc774\uc720\ub294 \uc804\uae30 \uc0ac\uc591\ub9cc \uc81c\uacf5\ub418\uae30 \ub54c\ubb38\uc785\ub2c8\ub2e4. \ub2e4\uc74c\uc740 \uc774\ub97c \uc5bb\ub294 \uc2e0\ub8b0\ud560 \uc218 \uc788\ub294 \ubc29\ubc95\uc785\ub2c8\ub2e4:<\/p>\n<ul>\n<li>\uc81c\uc870\uc5c5\uccb4\uc758 \ub370\uc774\ud130 \uc2dc\ud2b8 \/ \uae30\uc220 \uc0ac\uc591 \u2013 \uc694\uccad\ub41c \uc815\ubcf4\ub97c \ucc3e\uae30 \uc704\ud55c \ucd5c\uace0\uc758 \ucd9c\ucc98\uc785\ub2c8\ub2e4. \uc8fc\ubb38\ud558\uae30 \uc804\uc5d0 \uc694\uccad\ud558\uc138\uc694.<\/li>\n<li>\ud3ec\uc7a5 \ubaa9\ub85d \ubc0f \uc6b4\uc1a1\uc7a5 \u2013 \ubcc0\uc555\uae30\uac00 \uc774\ubbf8 \uadc0\ud558\uc758 \uc704\uce58\ub85c \ubc1c\uc1a1\ub41c \uacbd\uc6b0, \uc704\uc758 \ubb38\uc11c\uc5d0\uc11c \uc6b4\uc1a1 \ubb34\uac8c\ub97c \uc81c\uacf5\ud569\ub2c8\ub2e4.<\/li>\n<li>\ub9ac\ud504\ud305 \ub77c\ubca8 \ubc0f \ub9ac\uae45 \ub3c4\uba74 \u2013 \uc0c1\uc790\ub294 \ub9ac\ud504\ud305 \ubb34\uac8c\uc640 \ub9ac\uae45 \ud3ec\uc778\ud2b8\ub97c \ubaa8\ub450 \uac00\uc9c0\uace0 \uc788\uc73c\uba70, \uc7a5\uce58\ub294 \ubb34\uac8c\uc5d0 \ub530\ub77c \ud3c9\uac00\ub41c \uc790\uccb4 \ub9ac\ud504\ud305 \ub8e8\uadf8\ub97c \uac00\uc9c0\uace0 \uc788\uc2b5\ub2c8\ub2e4.<\/li>\n<li>\uce74\ud0c8\ub85c\uadf8\/\ucc38\uc870 \ud45c \u2013 \uc704\uc5d0\uc11c \uc5b8\uae09\ud55c \ud5c8\uc6a9 \uc624\ucc28 \ub0b4\uc5d0\uc11c \uacc4\ud68d\ud558\ub294 \ub370 \uc720\uc6a9\ud569\ub2c8\ub2e4.<\/li>\n<\/ul>\n<p>\uc720\ud1b5\uc5c5\uccb4\ub97c \ud1b5\ud574 \uad6c\ub9e4\ud558\uae30\ub85c \uacb0\uc815\ud558\uc2e0 \uacbd\uc6b0, \ub370\uc774\ud130 \uc2dc\ud2b8 \uc694\uccad\uc758 \uc911\uc694\uc131\uc744 \uc78a\uc9c0 \ub9c8\uc138\uc694(\ubb34\uac8c\ub294 \uc6b4\uc1a1 \uacac\uc801, \uae30\ucd08 \uc124\uacc4 \ub4f1\uc5d0 \uc911\uc694\ud569\ub2c8\ub2e4), \uadf8\ub807\uc9c0 \uc54a\uc73c\uba74 \uc815\ubcf4\ub97c \uc81c\uacf5\ud560 \uc218 \uc5c6\ub294 \ub51c\ub7ec\ub294 \uc758\uc2ec\uc2a4\ub7ec\uc6b4 \uac83\uc73c\ub85c \uac04\uc8fc\ud574\uc57c \ud569\ub2c8\ub2e4. \uc6b0\ub9ac\uc758 <a href=\"\/ko\/product\/distribution-transformer\/\">\ubc30\uc804 \ubcc0\uc555\uae30 \uc81c\ud488 \ud398\uc774\uc9c0<\/a> \uacf5\uae09\ud558\ub294 \uc7a5\uce58\uc758 \uc0ac\uc591 \uc2dc\ud2b8\ub97c \uac8c\uc2dc\ud569\ub2c8\ub2e4; \ud2b9\uc815 500 kVA \uc7a5\uce58\uc758 \ubb34\uac8c \ud655\uc778\uc744 \uc704\ud574 \uc81c\uc870\uc5c5\uccb4\uc758 \ub370\uc774\ud130 \uc2dc\ud2b8\uac00 \uad8c\uc704 \uc788\ub294 \ucd9c\ucc98\uc785\ub2c8\ub2e4.<\/p>\n<h2>\uc2e4\uc81c \ubb34\uac8c: \uc6b4\uc1a1 \ubc0f \uc124\uce58<\/h2>\n<p>\uc9c0\uae08 \ud655\uc778\ud55c \uc9c8\ub7c9\uc740 \uc138 \uac00\uc9c0 \ud6a8\uc728\uc801\uc778 \uc120\ud0dd\uc73c\ub85c \uc774\uc5b4\uc9d1\ub2c8\ub2e4:<\/p>\n<ul>\n<li>\uc6b4\uc1a1: 2\ud1a4 \ud56d\ubaa9\uc740 \ud3c9\uba74 \uce68\ub300\ub098 \ucee8\ud14c\uc774\ub108\uc5d0\uc11c \uc0c1\uc790\ub85c \uc6b4\uc1a1\ud574\uc57c \ud569\ub2c8\ub2e4; \ub3c4\uc911\uc5d0 \ub192\uc774 \ubc0f \ubb34\uac8c \uc81c\ud55c\uacfc \ub450 \ud130\ubbf8\ub110\uc5d0\uc11c\uc758 \ud06c\ub808\uc778 \uc811\uadfc \uac00\ub2a5\uc131\uc744 \ud655\uc778\ud558\uc138\uc694. \uc6b4\uc1a1 \ubb34\uac8c\ub294 \ubcc0\uc555\uae30 \ubb34\uac8c\uc758 \uc57d 1.1\ubc30\uc785\ub2c8\ub2e4.<\/li>\n<li>\ub9ac\ud504\ud305: \uc81c\uc870\uc5c5\uccb4\uc5d0 \ub530\ub77c \ub9ac\ud504\ud305 \ud3ec\uc778\ud2b8\ub97c \uc0ac\uc6a9\ud558\ub294 \uac83\uc774 \uc911\uc694\ud569\ub2c8\ub2e4 \u2014 \ub9ac\ud504\ud305 \ub8e8\uadf8\ub9cc \uc0ac\uc6a9\ud574\uc57c \ud558\uba70, \ubd80\uc2f1, \ud0f1\ud06c \ub9bd \ub610\ub294 \ub77c\ub514\uc5d0\uc774\ud130\ub294 \ud3ec\ud568\ub418\uc9c0 \uc54a\uc544\uc57c \ud569\ub2c8\ub2e4. 2,000-5,000 lb\uc758 \uc7a5\uce58 \ubb34\uac8c\ub294 10\ud1a4 \ud06c\ub808\uc778\uc744 \uc0ac\uc6a9\ud574\uc57c \ud558\uba70, \ub354 \ubb34\uac70\uc6b4 \uad6c\uc870\ubb3c\uc740 25\ud1a4 \ud06c\ub808\uc778\uc744 \uc6b4\uc601\ud558\uae30 \uc704\ud574 \ub354 \ud070 \uc778\ub825\uc774 \ud544\uc694\ud569\ub2c8\ub2e4. \uc6b0\ub9ac\uc758 <a href=\"\/ko\/blog\/transformer-transportation-and-rigging\/\">\ubcc0\uc555\uae30 \uc6b4\uc1a1 \ubc0f \ub9ac\uae45 \uac00\uc774\ub4dc<\/a> \ubb34\uac8c \ud074\ub798\uc2a4\ubcc4 \uc7a5\ube44 \ubc0f \uc548\uc804 \uaddc\uce59\uc744 \ub2e4\ub8f9\ub2c8\ub2e4.<\/li>\n<li>\uae30\ucd08 \ubc0f \ubc14\ub2e5 \ud558\uc911: \ubcc0\uc555\uae30\uc758 \ubb34\uac8c\ub97c \uacac\ub51c \uc218 \uc788\ub3c4\ub85d \ud328\ub4dc \ub610\ub294 \ubc14\ub2e5\uc744 \uc900\ube44\ud558\uc138\uc694. \ucd94\uac00\uc801\uc73c\ub85c \ucf00\uc774\uc2a4\uc758 \ubb34\uac8c\ub3c4 \uace0\ub824\ud574\uc57c \ud569\ub2c8\ub2e4. \uc624\uc77c\uc774 \ucc44\uc6cc\uc9c4 \uad6c\uc870\ubb3c\uc740 \uc624\uc77c\ub85c \ucc44\uc6cc\uc9c4 \ubcc0\uc555\uae30\uc758 \ucd1d \ubb34\uac8c\ub97c \uacac\ub51c \uc218 \uc788\ub294 \uae30\ucd08\uac00 \ud544\uc694\ud558\uba70, \uc774\ub294 \ube44\uc5b4 \uc788\ub294 \ubb34\uac8c\uc5d0 \ube44\ud574 \ud07d\ub2c8\ub2e4. \uc6b0\ub9ac\uc758 <a href=\"\/ko\/blog\/transformer-foundation-and-floor-loading\/\">\uae30\ucd08 \ubc0f \ubc14\ub2e5 \ud558\uc911 \uac00\uc774\ub4dc<\/a> \uc911\ud615 \uc7a5\uce58\uc5d0 \ub300\ud55c \ucf58\ud06c\ub9ac\ud2b8 \uc124\uacc4 \uae30\ubcf8 \uc0ac\ud56d\uc744 \ub2e4\ub8f9\ub2c8\ub2e4.<\/li>\n<\/ul>\n<p>\uc608\uc0b0 \ucc45\uc815 \uaddc\uce59: 500 kVA\uc758 \ubcc0\uc555\uae30 \uc124\uce58 \ube44\uc6a9 \ubc0f \uc6b4\uc1a1\ube44\ub294 \uc7a5\ube44 \uac00\uaca9\uc758 15-30%\ub97c \ucc28\uc9c0\ud569\ub2c8\ub2e4; \uad6c\uc870\ubb3c\uc758 \uc9c8\ub7c9\uc774 \uc774\ub7ec\ud55c \ube44\uc6a9\uc758 \uc8fc\uc694 \uc6d0\uc778\uc785\ub2c8\ub2e4.<\/p>\n<h2>\uc790\uc8fc \ubb3b\ub294 \uc9c8\ubb38<\/h2>\n<h3>1000 kVA \ubcc0\uc555\uae30\uc758 \ubb34\uac8c\ub294 \uc5bc\ub9c8\uc778\uac00\uc694?<\/h3>\n<p>1,000 kVA \ubcc0\uc555\uae30\uc758 \ud3c9\uade0 \uc911\ub7c9\uc740 \uc624\uc77c \ucda9\uc804 \ubaa8\ub378\uc758 \uacbd\uc6b0 \uc57d 3.1-4.5\ud1a4(\ub610\ub294 6,800-9,900 lb)\uc774\uba70, \uac74\uc2dd \uc7a5\ube44 \ubaa8\ub378\uc758 \uacbd\uc6b0 \uc57d 2.5-3.5\ud1a4\uc785\ub2c8\ub2e4. \ucd1d \uc911\ub7c9\uc740 \uc804\uc555 \ub4f1\uae09 \ubc0f \uc81c\uc870\uc5c5\uccb4\uc640 \uac19\uc740 \ub9e4\uac1c\ubcc0\uc218\uc5d0 \ub530\ub77c \ub2ec\ub77c\uc9d1\ub2c8\ub2e4. \uc77c\ubc18\uc801\uc73c\ub85c 10 kV \uc624\uc77c \ucda9\uc804 \uc911\uad6d \ubcc0\uc555\uae30\ub294 \uc57d 3.1\uc5d0\uc11c 3.6\ud1a4\uc73c\ub85c \ucd94\uc815\ub429\ub2c8\ub2e4. \ubcc0\uc555\uae30\uac00 \ub354 \ud6a8\uc728\uc801\uc774\uace0 \ubb34\uac70\uc6b8\uc218\ub85d \uc804\uc555 \ub4f1\uae09\uc774 \ub192\uc544\uc9d1\ub2c8\ub2e4.<\/p>\n<h3>500 kVA \ubc1c\uc804\uae30\uc758 \uc911\ub7c9\uc740 \uc5bc\ub9c8\uc785\ub2c8\uae4c?<\/h3>\n<p>500 kVA(\ub300\ub7b5 400-450 kW)\ub85c \ud3c9\uac00\ub41c \ub514\uc824 \ubc1c\uc804\uae30\uc758 \ud3c9\uade0 \uc911\ub7c9\uc740 \uae30\ucd08, \ubc29\uc5f4\uae30 \ubc0f \uc5f0\ub8cc \ud0f1\ud06c \uc911\ub7c9\uc744 \uace0\ub824\ud560 \ub54c 4,000\uc5d0\uc11c 8,000 kg(4\uc5d0\uc11c 8\ud1a4) \ubc94\uc704\uc5d0\uc11c \ub2ec\ub77c\uc9d1\ub2c8\ub2e4. \ub514\uc824 \ubc1c\uc804\uae30 \ubaa8\ub378\uc740 \uc77c\ubc18\uc801\uc73c\ub85c 500 kVA \ubcc0\uc555\uae30\ubcf4\ub2e4 \ubb34\uac81\uc2b5\ub2c8\ub2e4. \uc774\ub294 \uc5d4\uc9c4\uc774\ub098 \ubc1c\uc804\uae30\uc640 \uac19\uc740 \uc911\uc7a5\ube44\ub85c \uad6c\uc131\ub418\uc5b4 \uc788\uae30 \ub54c\ubb38\uc785\ub2c8\ub2e4. \uae30\uacc4\uc758 \uc911\ub7c9\uc740 \uc81c\uc870\uc5c5\uccb4 \ubc0f \uc778\ud074\ub85c\uc800\uc5d0 \ub530\ub77c \ub2ec\ub77c\uc9d1\ub2c8\ub2e4.<\/p>\n<h3>500 kVA \ubcc0\uc555\uae30\uc758 \uc0ac\uc591\uc740 \ubb34\uc5c7\uc785\ub2c8\uae4c?<\/h3>\n<p>\uc77c\ubc18\uc801\uc73c\ub85c \ud45c\uc900 \ub9e4\uac1c\ubcc0\uc218\ub97c \uac00\uc9c4 500-kVA \ubcc0\uc555\uae30\ub294 \ub2e4\uc74c\uacfc \uac19\uc740 \uc0ac\uc591\uc744 \uac00\uc9c8 \uc218 \uc788\uc2b5\ub2c8\ub2e4: 10 kV \/ 0.4 kV \ub610\ub294 11 kV\/0.433 kV, \uc0bc\uc0c1, 50\/60 Hz, Dyn11 \ubca1\ud130 \uadf8\ub8f9, \ubb34\ubd80\ud558 \uc190\uc2e4 \uc57d 0.68-0.98 kW, \ubd80\ud558 \uc190\uc2e4 \uc57d 5.7-6.2 kW, \ubb34\ubd80\ud558 \uc804\ub958 \uc57d 1%, \uc784\ud53c\ub358\uc2a4\ub294 4%\uc5d0\uc11c 6%\uae4c\uc9c0 \ub2e4\uc591\ud558\uba70, \uc7a5\ube44\uc758 \ucd1d \uc911\ub7c9\uc740 \uc57d 1.8\ud1a4, \uc624\uc77c \uc911\ub7c9\uc740 0.3-0.5\ud1a4\uc785\ub2c8\ub2e4. SCB \ud0c0\uc785\uc758 \uac74\uc2dd \ub300\uc548\uc740 F\uae09 \uc808\uc5f0\uc744 \uac00\uc9c0\uba70, \uc911\ub7c9\uc740 \uc57d 1.2 -1.8\ud1a4\uc774\uba70 \uc2e4\ub0b4\uc5d0 \uc124\uce58\ud560 \uc218 \uc788\uc2b5\ub2c8\ub2e4.<\/p>\n<h3>\uc804\ub825 \ubcc0\uc555\uae30\uc758 \uc911\ub7c9\uc740 \uc5bc\ub9c8\uc785\ub2c8\uae4c?<\/h3>\n<p>\uc804\ub825 \ubcc0\uc555\uae30\ub294 \ubc30\uc804 \ubcc0\uc555\uae30\ubcf4\ub2e4 \ubb34\uac81\uc2b5\ub2c8\ub2e4. \uc608\ub97c \ub4e4\uc5b4, 10 MVA\ub85c \ud3c9\uac00\ub41c \ubcc0\uc555\uae30\uc758 \uc911\ub7c9\uc740 \uc57d 15-25\ud1a4\uc774\uba70, 50 MVA \ubcc0\uc555\uae30\ub294 40\uc5d0\uc11c 65\ud1a4 \uc0ac\uc774\uc785\ub2c8\ub2e4. 220 kV \ubc94\uc704\uc758 \ubcc0\uc555\uae30\ub294 \uc57d 80-150\ud1a4\uc758 \uc911\ub7c9\uc744 \uac00\uc9d1\ub2c8\ub2e4. \ubc30\uc804 \ubcc0\uc555\uae30\ub294 \uac00\uc7a5 \uac00\ubcbc\uc6b4 \ubcc0\uc555\uae30\uc774\ubbc0\ub85c, \uc911\ub7c9\uc740 \ubcc0\uc555\uae30\uc758 \uc815\uaca9 \ubc0f \uc804\uc555 \ub4f1\uae09\uc5d0 \ub530\ub77c \ub2ec\ub77c\uc9d1\ub2c8\ub2e4.<\/p>\n<h2>\ucc38\uace0 \ubb38\ud5cc<\/h2>\n<ul>\n<li><a href=\"https:\/\/transformer4u.com\/transformer-weight-chart-by-kva-complete-reference-table-2026\/\" rel=\"nofollow noopener\" target=\"_blank\">Transformer4U \u2014 kVA\uc5d0 \ub530\ub978 \ubcc0\uc555\uae30 \uc911\ub7c9 \ucc28\ud2b8 \ubc0f \ucd94\uc815 \uacf5\uc2dd<\/a><\/li>\n<li><a href=\"https:\/\/b2bwiki.baidu.com\/article\/d0r2pq9ftjsv1cjniqgg\" rel=\"nofollow noopener\" target=\"_blank\">Baidu B2B Wiki \u2014 \uc6a9\ub7c9\uc5d0 \ub530\ub978 \ubcc0\uc555\uae30 \uc911\ub7c9 (GB\/T \ucc38\uc870 \ub370\uc774\ud130)<\/a><\/li>\n<li><a href=\"https:\/\/wcheng.nmbcp.com\/news\/15534.html\" rel=\"nofollow noopener\" target=\"_blank\">Runsen Transformer \u2014 kVA\uc5d0 \ub530\ub978 S11 \uc2dc\ub9ac\uc988 \uc911\ub7c9 \ucc38\uc870<\/a><\/li>\n<li><a href=\"https:\/\/es.made-in-china.com\/co_2d2c2d439714f097\/product_500kVA-Oil-Immersed-Industrial-Transformer-10kv-0-4kv-50Hz-Class-H-Insulation_yyggsgrhhg.html\" rel=\"nofollow noopener\" target=\"_blank\">Tianhong Power \u2014 500 kVA \uc624\uc77c \uce68\uc9c0 \ubcc0\uc555\uae30 \uae30\uc220 \ub370\uc774\ud130 (\uc911\ub7c9, \uc190\uc2e4)<\/a><\/li>\n<li><a href=\"https:\/\/www.energy.gov\/\" rel=\"nofollow noopener\" target=\"_blank\">US DOE \u2014 \ubc30\uc804 \ubcc0\uc555\uae30 \ud6a8\uc728 \ubc0f \uc124\uacc4 \uae30\uc900<\/a><\/li>\n<\/ul>\n<h2>\uacb0\ub860<\/h2>\n<p>500 kVA\ub85c \ud3c9\uac00\ub41c \ubcc0\uc555\uae30\uc758 \uc911\ub7c9\uc740 \ucd94\uc815\ub429\ub2c8\ub2e4. \uac01 \uac74\uc2dd \ubcc0\uc555\uae30\ub294 1.2\ud1a4\uc5d0\uc11c 1.8\ud1a4 \uc0ac\uc774\uc758 \uc911\ub7c9\uc744 \uac00\uc9c0\uba70, \uac01 \uc624\uc77c \uce68\uc9c0 \ubcc0\uc555\uae30\uc758 \uc774\ub860\uc801 \uc911\ub7c9 \uacc4\uc0b0\uc740 \ub354 \ub9ce\uc2b5\ub2c8\ub2e4. \ud6c4\uc790\ub294 \uc0ac\uc6a9\ub41c \uad8c\uc120 \uc7ac\ub8cc, \ud6a8\uc728 \ub4f1\uae09 \ubc0f \ubcc0\uc555\uae30 \uc81c\uc870\uc5c5\uccb4\uc640 \uac19\uc740 \uc5ec\ub7ec \uc694\uc778\uc5d0 \ub530\ub77c \uc57d 1.8\ud1a4\uc5d0\uc11c 2.5\ud1a4\uae4c\uc9c0 \ubb34\uac8c\uac00 \ub098\uac11\ub2c8\ub2e4. \uc774 \ubb38\uc11c\uc5d0 \uc81c\uc2dc\ub41c \ubc29\uc815\uc2dd\uc744 \uc0ac\uc6a9\ud558\uba74 \ud2b8\ub7ed, \ud06c\ub808\uc778 \ub610\ub294 \uae30\ucd08 \uacc4\ud68d\uc744 \uc138\uc6b0\uae30 \uc804\uc5d0 \uc911\ub7c9\uc744 \ucd94\uc815\ud560 \uc218 \uc788\uc2b5\ub2c8\ub2e4.<\/p>","protected":false},"excerpt":{"rendered":"<p>Weighing up the acquisition of a transformer rated at 500 kVA, one of the essential factors to take into account is the weight of the transformer. The weight of the transformer would dictate the kind of transport vehicle that will be required, crane specifications, foundation, loading and air clearance as well as access to your [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":11179,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-11178","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/subian-electric.com\/ko\/wp-json\/wp\/v2\/posts\/11178","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/subian-electric.com\/ko\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/subian-electric.com\/ko\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/subian-electric.com\/ko\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/subian-electric.com\/ko\/wp-json\/wp\/v2\/comments?post=11178"}],"version-history":[{"count":4,"href":"https:\/\/subian-electric.com\/ko\/wp-json\/wp\/v2\/posts\/11178\/revisions"}],"predecessor-version":[{"id":11189,"href":"https:\/\/subian-electric.com\/ko\/wp-json\/wp\/v2\/posts\/11178\/revisions\/11189"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/subian-electric.com\/ko\/wp-json\/wp\/v2\/media\/11179"}],"wp:attachment":[{"href":"https:\/\/subian-electric.com\/ko\/wp-json\/wp\/v2\/media?parent=11178"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/subian-electric.com\/ko\/wp-json\/wp\/v2\/categories?post=11178"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/subian-electric.com\/ko\/wp-json\/wp\/v2\/tags?post=11178"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}