{"id":11424,"date":"2026-09-03T00:56:14","date_gmt":"2026-09-02T16:56:14","guid":{"rendered":"https:\/\/subian-electric.com\/?p=11424"},"modified":"2026-09-03T00:58:11","modified_gmt":"2026-09-02T16:58:11","slug":"what-is-the-basic-insulation-level-bil","status":"publish","type":"post","link":"https:\/\/subian-electric.com\/ko\/blog\/what-is-the-basic-insulation-level-bil\/","title":{"rendered":"\uae30\ubcf8 \uc808\uc5f0 \uc218\uc900(BIL)\uc774\ub780 \ubb34\uc5c7\uc785\ub2c8\uae4c?"},"content":{"rendered":"<p>\ubcc0\uc555\uae30 \uc0ac\uc591 \uc2dc\ud2b8\ub97c \ub4e4\uace0 \uc0b4\ud3b4\ubcf4\uba74, \uae30\ubcf8 \uc808\uc5f0 \uc218\uc900(Basic Insulation Level) \ub610\ub294 \uc904\uc5ec\uc11c BIL\uc774\ub77c\uace0 \ud558\ub294 \uac83\uc5d0 \ub300\ud55c \uc815\ubcf4\ub97c \ucc3e\uac8c \ub420 \uac83\uc785\ub2c8\ub2e4 \u2014 \uc608: \u201cBIL: 95 kV\u201d \ub610\ub294 \u201cBIL: 150 kV.\u201d \uc774\ub7ec\ud55c \ub4f1\uae09\uc5d0 \ub300\ud55c \uc9c8\ubb38\uc774 \uc788\uac70\ub098 \ub450 \uac1c\uc758 \uc720\uc0ac\ud55c \ubcc0\uc555\uae30\uac00 \uc11c\ub85c \ub2e4\ub978 BIL \ub4f1\uae09\uc744 \uac00\uc9c8 \uc218 \uc788\ub2e4\ub294 \uc0ac\uc2e4\uc5d0 \ud63c\ub780\uc2a4\ub7ec\uc6e0\ub2e4\uba74, \uc774 \uae30\uc0ac\ub294 \ubc14\ub85c \ub2f9\uc2e0\uc744 \uc704\ud55c \uac83\uc785\ub2c8\ub2e4. \uae30\ubcf8 \uc808\uc5f0 \uc218\uc900\uc740 \uc2e4\uc81c\ub85c \uc808\uc5f0 \uc870\uc815\uc744 \uae30\ub85d\ud558\ub294 \uac00\uc7a5 \uc911\uc694\ud55c \uc0ac\uc591\uc785\ub2c8\ub2e4.<\/p>\n<blockquote><p>\uac04\ub2e8\ud788 \ub9d0\ud574, BIL \ub610\ub294 \uae30\ubcf8 \uc808\uc5f0 \uc218\uc900\uc774\ub77c\ub294 \uc6a9\uc5b4\ub294 \ubc88\uac1c \uc784\ud384\uc2a4 \ud30c\uc758 \ucd5c\ub300 \uc804\uc555\uc5d0 \ub300\ud574 \uc815\uc758\ub41c \ubcc0\uc555\uae30\uc758 \uc808\uc5f0 \ub4f1\uae09\uc744 \uc758\ubbf8\ud558\uba70 BIL\uc774 \ubb34\uc5c7\uc778\uc9c0 \uba85\ud655\ud788 \ud569\ub2c8\ub2e4. BIL\uc744 \uaddc\uc81c\ud558\ub294 \ud45c\uc900\uc740 IEC 60076-3 \ubc0f IEEE\/ANSI C57.12.00\uc5d0\uc11c \uc18c\uac1c\ub429\ub2c8\ub2e4. BIL\uc740 kV(\ud53c\ud06c)\ub85c \ud45c\ud604\ub429\ub2c8\ub2e4. BIL\uc744 \uacb0\uc815\ud558\uae30 \uc704\ud574\uc11c\ub294 \uc815\uaca9 BIL \uc218\uc900\uc5d0\uc11c 1.2\/50 \u03bcs\uc758 \ubc88\uac1c \uc784\ud384\uc2a4 \ud30c\uac00 \uc8fc\uc785\ub418\ub294 \uc804\ud30c \ud14c\uc2a4\ud2b8\uac00 \uc218\ud589\ub429\ub2c8\ub2e4. \uc2ec\uac01\ud55c \ubc88\uac1c \ub178\ucd9c, \ub0ae\uc740 \uc808\uc5f0 \uc5ec\uc720, \uc8fc\uc694 \uc2dc\uc2a4\ud15c \uc804\uc555\uc758 \uacbd\uc6b0 \ub354 \ub192\uc740 BIL\uc744 \ucc44\ud0dd\ud574\uc57c \ud558\uc9c0\ub9cc, BIL\uc740 \uc784\ud384\uc2a4 \ub0b4\uc804\uc555\uc5d0\ub9cc \uc801\uc6a9\ub418\uba70 \ud50c\ub798\uc2dc\uc624\ubc84 \ub610\ub294 \uc11c\uc9c0 \uc804\uc555\uc5d0 \ub300\ud55c \ubcf4\ud638\ub97c \ubcf4\uc7a5\ud558\uc9c0 \uc54a\ub294\ub2e4\ub294 \uc810\uc744 \uae30\uc5b5\ud574\uc57c \ud569\ub2c8\ub2e4.<\/p><\/blockquote>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-11426\" src=\"https:\/\/subian-electric.com\/wp-content\/uploads\/2026\/09\/What-Is-the-Basic-Insulation-Level-BIL.webp\" alt=\"\uae30\ubcf8 \uc808\uc5f0 \uc218\uc900(BIL)\uc774\ub780 \ubb34\uc5c7\uc785\ub2c8\uae4c?\" width=\"1448\" height=\"1086\" \/><\/p>\n<h2>BIL\uc758 \uc758\ubbf8<\/h2>\n<p>\uae30\ubcf8 \uc808\uc5f0 \uc218\uc900(BIL)\uc740 \ubc88\uac1c \uc784\ud384\uc2a4\uc5d0 \uc758\ud574 \uc815\uc758\ub41c \ucd5c\ub300 \uc804\uc555\uc744 \uc758\ubbf8\ud569\ub2c8\ub2e4. \ubc88\uac1c\uac00 \uc1a1\uc804\uc120\uc5d0 \ub5a8\uc5b4\uc9c0\uac70\ub098 \uc11c\uc9c0\uac00 \uc2dc\uc2a4\ud15c\uc744 \ud1b5\uacfc\ud560 \ub54c \uc804\uae30 \uc11c\uc9c0\uac00 \ubc1c\uc0dd\ud558\uc5ec \uc2dc\uc2a4\ud15c\uc758 \uc77c\ubc18 \uc791\ub3d9 \uc804\uc555\uc744 \ucd08\uacfc\ud558\ub294 \uc804\uc555 \ud30c\ud615\uc744 \uc0dd\uc131\ud569\ub2c8\ub2e4. BIL\uc740 \ubcc0\uc555\uae30\uac00 \uc808\uc5f0\uc774 \ud30c\uad34\ub418\uc9c0 \uc54a\uace0 \ubc88\uac1c\uc5d0 \uc758\ud574 \uc0dd\uc131\ub41c \uc11c\uc9c0\ub97c \ucc98\ub9ac\ud560 \uc218 \uc788\ub3c4\ub85d \uacc4\uc0b0\ub41c \uac12\uc774\uba70, 95\ud0ac\ub85c\ubcfc\ud2b8\uc640 \uac19\uc740 \ud0ac\ub85c\ubcfc\ud2b8\ub85c \ud45c\ud604\ub420 \uc218 \uc788\uc2b5\ub2c8\ub2e4.<\/p>\n<p>BIL\uc740 \uc808\uc5f0 \uc2e4\ud328\uac00 \uc2ec\uac01\ud55c \ubb38\uc81c\ub97c \uc77c\uc73c\ud0ac \uc218 \uc788\uace0 \ube44\uc6a9\uc774 \ub9ce\uc774 \ub4e4 \uc218 \uc788\uae30 \ub54c\ubb38\uc5d0 \ud2b9\ud788 \uc911\uc694\ud569\ub2c8\ub2e4. \ub0b4\ubd80\uc5d0\uc11c \ud50c\ub798\uc2dc\uac00 \ubc1c\uc0dd\ud55c \ubcc0\uc555\uae30\ub294 \uadf8 \uc790\ub9ac\uc5d0\uc11c \uc218\ub9ac\ud560 \uc218 \uc5c6\uc2b5\ub2c8\ub2e4. BIL\uc740 \uc124\uacc4\uc790\uc640 \uad6c\ub9e4\uc790 \ubaa8\ub450\uc5d0\uac8c \uacf5\ud1b5 \uc5b8\uc5b4\ub97c \uc81c\uacf5\ud569\ub2c8\ub2e4 \u2014 \u201c\uc774 \ubcc0\uc555\uae30\ub294 15 kV\ub85c \uc815\uaca9\ub418\uc5b4 \uc788\uc73c\uba70 95 kV\uc758 \ubc88\uac1c\uc5d0 \uc758\ud574 \uc0dd\uc131\ub41c \uc804\uc555 \uc11c\uc9c0\ub97c \ucc98\ub9ac\ud560 \uc218 \uc788\uc2b5\ub2c8\ub2e4\u201d \u2014 \ub530\ub77c\uc11c \ubcf8\uc9c8\uc801\uc73c\ub85c \ubaa8\ub4e0 \uc808\uc5f0 \uc870\uc815 \ud504\ub85c\uc138\uc2a4\ub97c \ud558\ub098\uc758 \ud328\ub110\ub85c \ud1b5\ud569\ud558\uc5ec \uc7a5\uce58\uc5d0 \uc81c\uacf5\ub418\ub294 \ubcf4\ud638 \uc218\uc900\uc744 \ud560\ub2f9\ud569\ub2c8\ub2e4. <a href=\"\/ko\/blog\/transformer-specifications-explained\/\">\ubcc0\uc555\uae30 \uc0ac\uc591 \uac00\uc774\ub4dc<\/a> BIL\uc774 \uba85\ud310 \ubc0f \ub370\uc774\ud130 \uc2dc\ud2b8\uc758 \ub2e4\ub978 \ub4f1\uae09 \uc0ac\uc774\uc5d0\uc11c \uc5b4\ub514\uc5d0 \uc704\uce58\ud558\ub294\uc9c0\ub97c \uc124\uba85\ud569\ub2c8\ub2e4.<\/p>\n<h2>BIL \uce21\uc815 \ubc0f \ud14c\uc2a4\ud2b8 \ubc29\ubc95<\/h2>\n<p>BIL\uc740 \ucd94\uc815\uc5d0 \uc758\ud574 \uc5bb\uc5b4\uc9c4 \uac04\ub2e8\ud55c \uac12\uc774 \uc544\ub2d9\ub2c8\ub2e4. \uc2e4\uc81c\ub85c\ub294 \ud14c\uc2a4\ud2b8 \uc218\uc900\uc744 \uc758\ubbf8\ud569\ub2c8\ub2e4. BIL\uc758 \uac80\uc99d\uc740 \uc77c\ubc18\uc801\uc73c\ub85c IEEE C57.12.90 \ubc0f IEC 60076-3\uc5d0 \ub530\ub77c \uc804\uccb4 \ud30c\ud615 \ubc88\uac1c \uc784\ud384\uc2a4 \ud14c\uc2a4\ud2b8\ub97c \uc218\ud589\ud558\ub294 \uac83\uc744 \uc758\ubbf8\ud569\ub2c8\ub2e4:<\/p>\n<ul>\n<li>\ud14c\uc2a4\ud2b8\ub294 1.2\/50 \u00b5s\uc758 \ud30c\ud615\uc73c\ub85c \ubc88\uac1c \uc784\ud384\uc2a4\ub97c \uc801\uc6a9\ud558\ub294 \uac83\uc73c\ub85c \uad6c\uc131\ub429\ub2c8\ub2e4 \u2014 \uc784\ud384\uc2a4\uc758 \uc0c1\uc2b9 \uc2dc\uac04\uc740 1.2 \u00b5s\uc774\uace0 \ud30c\ud615\uc758 \uac10\uc18c\ub294 50 \u00b5s\uac00 \uac78\ub9ac\uba70, \ub530\ub77c\uc11c \ubc88\uac1c \ud0c0\uaca9\uc758 \ud6a8\uacfc\ub97c \ubaa8\ub378\ub9c1\ud569\ub2c8\ub2e4.<\/li>\n<li>\ud30c\ud615\uc758 \ud53c\ud06c\ub294 \uc815\uaca9 BIL(\uc608: 15 kV \ubcc0\uc555\uae30\uc758 \uacbd\uc6b0 95 kV)\uacfc \uc77c\uce58\ud569\ub2c8\ub2e4.<\/li>\n<li>\ubcc0\uc555\uae30\ub294 \ud50c\ub798\uc2dc\uc624\ubc84\ub098 \uc808\uc5f0 \uc2e4\ud328 \uc5c6\uc774 \uc815\uc758\ub41c \ucd5c\uc18c\ud55c\uc758 \uc801\uc6a9 \ud69f\uc218\ub97c \uacac\ub51c \uc218 \uc788\uc2b5\ub2c8\ub2e4.<\/li>\n<li>\uace0\uc804\uc555 \ubcc0\uc555\uae30\ub294 \ucd94\uac00\uc801\uc778 \uc808\ub2e8\ud30c \ubc0f \uc2a4\uc704\uce6d \uc784\ud384\uc2a4 \ud14c\uc2a4\ud2b8\ub97c \uac70\uce58\uc9c0\ub9cc, BIL\uc740 \ud56d\uc0c1 \uc804\uccb4 \ud30c\ud615 \ubc88\uac1c \uc784\ud384\uc2a4 \ub0b4\uc804\uc555 \uc218\uc900\uc73c\ub85c \uc815\uc758\ub429\ub2c8\ub2e4.<\/li>\n<\/ul>\n<p>\uc2e4\uc9c8\uc801\uc73c\ub85c BIL\uc740 \uc2e4\ud5d8\uc2e4 \ud14c\uc2a4\ud2b8 \uc911 \uc0d8\ud50c \ub610\ub294 \uc0dd\uc0b0 \ub2e8\uc704\uc5d0\uc11c \uc785\uc99d\ud574\uc57c \ud558\ub294 \ud53c\ud06c \uac12\uc744 \ub098\ud0c0\ub0c5\ub2c8\ub2e4. \uc804\uccb4 \uc218\uc6a9 \ud14c\uc2a4\ud2b8 \uc138\ud2b8 \u2014 \uc784\ud384\uc2a4 \ud14c\uc2a4\ud2b8\ub97c \ud3ec\ud568\ud558\uc5ec \u2014 \ub294 \uc6b0\ub9ac\uc758 <a href=\"\/ko\/blog\/transformer-testing-guide\/\">\ubcc0\uc555\uae30 \ud14c\uc2a4\ud2b8 \uac00\uc774\ub4dc<\/a>, \uc5d0 \ud3ec\ud568\ub418\uc5b4 \uc788\uc2b5\ub2c8\ub2e4. \ub300\ubd80\ubd84\uc758 \uc808\uc5f0 \uc2e4\ud328\ub294 \ucd9c\ud558 \uc804\uc5d0 \ubc1c\uacac\ud558\uae30 \uc704\ud574 \uacf5\uc7a5 \ud14c\uc2a4\ud2b8\uac00 \uc874\uc7ac\ud558\ub294 \uacb0\ud568\uc73c\ub85c \uac70\uc2ac\ub7ec \uc62c\ub77c\uac11\ub2c8\ub2e4.<\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-11427\" src=\"https:\/\/subian-electric.com\/wp-content\/uploads\/2026\/09\/Standard-BIL-Levels-Reference-Tables.webp\" alt=\"\ud45c\uc900 BIL \uc218\uc900 (\ucc38\uc870 \ud45c)\" width=\"1448\" height=\"1086\" \/><\/p>\n<h2>\ud45c\uc900 BIL \uc218\uc900 (\ucc38\uc870 \ud45c)<\/h2>\n<p>IEEE\/ANSI C57.12.00\uc5d0\uc11c\ub294 \uc624\uc77c\uc5d0 \ub2f4\uae34 \ubcc0\uc555\uae30\uc5d0 \ub300\ud55c \uc815\uc0c1 BIL \uac12\uc774 \uc790\uc138\ud788 \uc124\uba85\ub418\uc5b4 \uc788\uc2b5\ub2c8\ub2e4. \uad75\uac8c \ud45c\uc2dc\ub41c BIL \uac12\uc740 \ubaa8\ub4e0 \uc804\uc555 \ud074\ub798\uc2a4\uc5d0 \ub300\ud55c \ud45c\uc900 \uac12\uc785\ub2c8\ub2e4:<\/p>\n<table>\n<tbody>\n<tr>\n<th>\uba85\ubaa9 \uc2dc\uc2a4\ud15c \uc804\uc555 (kV)<\/th>\n<th>\ud45c\uc900 BIL (kV \ud53c\ud06c)<\/th>\n<th>\uc77c\ubc18 \uac10\uc18c BIL<\/th>\n<\/tr>\n<tr>\n<td>2 (\ubc30\uc804)<\/td>\n<td>30<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>2.5<\/td>\n<td>45<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>60<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>8.7<\/td>\n<td>75<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>15 (\ubc30\uc804)<\/td>\n<td>95<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>25<\/td>\n<td>150<\/td>\n<td>125<\/td>\n<\/tr>\n<tr>\n<td>34.5<\/td>\n<td>200<\/td>\n<td>150<\/td>\n<\/tr>\n<tr>\n<td>46<\/td>\n<td>250<\/td>\n<td>200<\/td>\n<\/tr>\n<tr>\n<td>69<\/td>\n<td>350<\/td>\n<td>250<\/td>\n<\/tr>\n<tr>\n<td>115<\/td>\n<td>550<\/td>\n<td>450 \/ 350<\/td>\n<\/tr>\n<tr>\n<td>138<\/td>\n<td>650<\/td>\n<td>550 \/ 450<\/td>\n<\/tr>\n<tr>\n<td>161<\/td>\n<td>750<\/td>\n<td>650 \/ 550<\/td>\n<\/tr>\n<tr>\n<td>230<\/td>\n<td>900<\/td>\n<td>825 \/ 750<\/td>\n<\/tr>\n<tr>\n<td>345<\/td>\n<td>1,175<\/td>\n<td>1,050 \/ 900<\/td>\n<\/tr>\n<tr>\n<td>500<\/td>\n<td>1,675<\/td>\n<td>1,550 \/ 1,425<\/td>\n<\/tr>\n<tr>\n<td>765<\/td>\n<td>2,050<\/td>\n<td>1,925 \/ 1,800<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\uac74\uc2dd \ubcc0\uc555\uae30 (IEEE C57.12.01)\uc758 \uacbd\uc6b0, \ub3d9\uc77c\ud55c \uc804\uc555 \uc218\uc900\uc5d0 \ub300\ud55c BIL \uac12\uc774 \ub354 \ub0ae\uc2b5\ub2c8\ub2e4. \uc608\ub97c \ub4e4\uc5b4, 15 kV \uac74\uc2dd \ubcc0\uc555\uae30\uc758 BIL \ub4f1\uae09\uc740 \uc77c\ubc18\uc801\uc73c\ub85c 95 \ub610\ub294 110 kV\uc785\ub2c8\ub2e4. IEC \uc2dc\uc2a4\ud15c (IEC 60076-3)\uc5d0\ub3c4 BIL \ub4f1\uae09 \ud45c\uac00 \uc788\uc73c\uba70, BIL \uac12\uc740 \ucd5c\uace0 \uc2dc\uc2a4\ud15c \uc804\uc555 Um\uc5d0 \ub530\ub77c \uacc4\uc0b0\ub429\ub2c8\ub2e4. \uc608\ub97c \ub4e4\uc5b4, 12 kV \uc2dc\uc2a4\ud15c\uc758 BIL \uac12\uc740 75 kV, 24 kV \u2192 125 kV, 36 kV \u2192 170 kV, 72.5 kV \u2192 325 kV, 123 kV \u2192 550 kV, 145 kV \u2192 650 kV, 245 kV \u2192 1,050 kV\uc785\ub2c8\ub2e4. \uadc0\ud558\uc758 \ud504\ub85c\uc81d\ud2b8\ub97c \uc9c0\ubc30\ud558\ub294 \ud45c\uc900\uc774 \ubb34\uc5c7\uc774\ub4e0, \uc0ac\uc591 \ud504\ub85c\uc138\uc2a4\ub294 \ub3d9\uc77c\ud558\uba70, <a href=\"\/ko\/blog\/distribution-transformer-basics\/\">\ubc30\uc804 \ubcc0\uc555\uae30 \uae30\ucd08<\/a> \uae30\uc0ac\ub294 \uc804\uc555 \ud074\ub798\uc2a4\uc640 BIL\uc774 \uc720\ud2f8\ub9ac\ud2f0 \ubc0f \uc0b0\uc5c5 \uc6a9\ub3c4\ub85c \ud568\uaed8 \uc120\ud0dd\ub418\ub294 \ubc29\ubc95\uc744 \ubcf4\uc5ec\uc90d\ub2c8\ub2e4.<\/p>\n<h2>\ub354 \ub192\uc740 BIL\uc744 \uc9c0\uc815\ud574\uc57c \ud560 \ub54c<\/h2>\n<p>\ud45c\uc900 BIL\uc740 \ub124 \uac00\uc9c0 \uc774\uc720\ub85c \uc218\uc900\uc744 \ub192\uc5ec\uc57c \ud560 \ub54c \uae30\uc900\uc120\uc73c\ub85c \ubcfc \uc218 \uc788\uc2b5\ub2c8\ub2e4:<\/p>\n<ul>\n<li>\ubc88\uac1c \uc704\ud5d8\uc774 \ub192\uc740 \uc7a5\uc18c. \uc0b0\uc545 \uc9c0\uc5ed, \uc5f0\uac04 \ubc1c\uc0dd\ud558\ub294 \ucc9c\ub465\ubc88\uac1c \uc218\uac00 \ub9ce\uc740 \uc9c0\uc5ed, \uae34 \ub178\ucd9c\uc120 \ub4f1\uc774 \ub354 \ub192\uc740 BIL\uc744 \uc0ac\uc6a9\ud558\ub294 \uc774\uc720\uac00 \ub420 \uc218 \uc788\uc2b5\ub2c8\ub2e4.<\/li>\n<li>\ubcf4\ud638 \uc5ec\uc720\uac00 \ubd80\uc871\ud55c \uacbd\uc6b0. \uace0\uc11c\uc9c0 \ud658\uacbd \uc870\uac74\uc5d0\uc11c \uc544\ub808\uc2a4\ud130\ub97c \ubc30\uce58\ud560 \uc218 \uc788\ub294 \uac00\ub2a5\uc131\uc5d0 \uc81c\ud55c\uc774 \uc788\uc744 \ub54c, \uc774 \ub192\uc740 \uc218\uc900\uc758 \ubcf4\ud638\uac00 \uadf8 \uac70\ub9ac\uc640 \uc784\ud53c\ub358\uc2a4\ub97c \ubcf4\uc644\ud560 \uc218 \uc788\uc2b5\ub2c8\ub2e4.<\/li>\n<li>\uc911\uc694\ud558\uac70\ub098 \uad50\uccb4\ud558\uae30 \uc5b4\ub824\uc6b4 \uc7a5\uce58.<\/li>\n<li>\ubcf4\ud638 \uc218\uc900 \uac10\uc18c. \uac10\uc18c\ub41c BIL \ud06c\uae30\ub97c \uc9c0\uc815\ud568\uc73c\ub85c\uc368 \ube44\uc6a9\uc744 \uc808\uac10\ud560 \uc218 \uc788\uc9c0\ub9cc, \uc774\ub294 \uc544\ub808\uc2a4\ud130\uc758 \uc2e0\uc911\ud55c \uc870\uc815\uc744 \uc694\uad6c\ud569\ub2c8\ub2e4.<\/li>\n<\/ul>\n<p>\ub192\uc740 BIL \uc218\uc900\uc740 \uc124\uacc4 \ub2e8\uacc4\uc5d0\uc11c \uc608\uc0c1\ub418\ub294 \uc808\uc5f0 \ubc0f \uac04\uaca9 \ubb38\uc81c\ub97c \ud574\uacb0\ud558\uae30 \uc704\ud574 \uc0c1\ub2f9\ud55c \uae08\uc561\uc758 \ud22c\uc790\ub97c \uc694\uad6c\ud569\ub2c8\ub2e4. \ub530\ub77c\uc11c \uc801\uc808\ud55c \uc5d4\uc9c0\ub2c8\uc5b4\ub9c1\uc740 \ud56d\uc0c1 \uc870\uc815 \uc5f0\uad6c\ub97c \ud3ec\ud568\ud569\ub2c8\ub2e4. \uadf8 \uc5f0\uad6c\uc758 \uc811\uc9c0 \ubc0f \uc544\ub808\uc2a4\ud130 \uce21\uba74\uc740 \uc6b0\ub9ac\uc758 <a href=\"\/ko\/blog\/transformer-grounding-basics\/\">\ubcc0\uc555\uae30 \uc811\uc9c0 \uae30\ucd08<\/a> \uae30\uc0ac\uc5d0\uc11c \ub2e4\ub8e8\uc5b4\uc9c0\uba70, \uc811\uc9c0 \uc2dc\uc2a4\ud15c\uc774 \uc11c\uc9c0 \uc5d0\ub108\uc9c0\uac00 \uc2e4\uc81c\ub85c \uc5b4\ub5bb\uac8c \uc18c\uc0b0\ub418\ub294\uc9c0\ub97c \uacb0\uc815\ud569\ub2c8\ub2e4.<\/p>\n<h2>BIL\uc774 \ub2e4\ub8e8\uc9c0 \uc54a\ub294 \uac83<\/h2>\n<p>BIL\uc5d0 \uad00\ud574 \ud655\uc2e4\ud55c \ud55c \uac00\uc9c0\ub294 \u201c\uc784\ud384\uc2a4 \ub0b4\uc804\uc555\u201d\uc758 \uce21\uba74\uc785\ub2c8\ub2e4. \uadf8\ub7ec\ub098 \uc774\ub97c \uc77c\ubc18\ud654\ud558\ub294 \uad6c\ub9e4\uc790\ub294 \ub180\ub77c\uc6c0\uc744 \uacaa\uac8c \ub429\ub2c8\ub2e4. BIL\uc740 \ub2e4\uc74c\uc744 \uc81c\uacf5\ud558\uc9c0 \uc54a\uc2b5\ub2c8\ub2e4:<\/p>\n<ul>\n<li>\uc624\uc5fc\uc73c\ub85c \uc778\ud55c \ud50c\ub798\uc2dc\uc624\ubc84 \ubb38\uc81c. \uc624\uc5fc\ub41c \ubd80\uc2f1\uc774\ub098 \uc808\uc5f0\uccb4\ub294 \ubc88\uac1c\uac00 \ub3c4\ub2ec\ud558\uae30 \uc804\uc5d0 \uc815\uc0c1 \uc791\ub3d9 \uc804\uc555\uc5d0\uc11c \ud50c\ub798\uc2dc\uc624\ubc84\uac00 \ubc1c\uc0dd\ud560 \uc218 \uc788\uc2b5\ub2c8\ub2e4. \uc774\ub294 \ud06c\ub9ac\ud398\uc774\uc9c0 \uac70\ub9ac \ubc0f \uc624\uc5fc \ub4f1\uae09 \ubb38\uc81c\uc774\uba70, BIL \ubb38\uc81c\ub294 \uc544\ub2d9\ub2c8\ub2e4.<\/li>\n<li>\uc804\ub825 \uc8fc\ud30c\uc218 \uacfc\uc804\uc555. \uacfc\uc804\uc555\uc774 \uc9c0\uc18d\ub418\ub294 \uc774\uc720\ub294 \uc870\uc815\uae30\uc758 \uc624\uc791\ub3d9 \ub610\ub294 \ud398\ub85c\ub808\uc870\ub10c\uc2a4 \ub54c\ubb38\uc774\uba70, \uc774\ub294 \uc808\uc5f0\uccb4\uc5d0 \uc5f4\uc801 \ubc0f \uc804\uae30\uc801 \uc2a4\ud2b8\ub808\uc2a4\ub97c \uac00\ud558\uac8c \ub429\ub2c8\ub2e4. \uc804\ub825 \ubcc0\uc555\uae30\uc758 \uc791\ub3d9 \uc2dc\uac04\uc740 \ub9c8\uc774\ud06c\ub85c\ucd08 \uc784\ud384\uc2a4 \ud14c\uc2a4\ud2b8\uc5d0\uc11c \uace0\ub824\ub418\uc9c0 \uc54a\uc2b5\ub2c8\ub2e4.<\/li>\n<li>\ub0b4\ubd80 \uc57d\uc810. BIL \ud14c\uc2a4\ud2b8\ub294 \uc57d\uc810\uc744 \ud3ec\ucc29\ud560 \uc218 \uc788\uc9c0\ub9cc, \uc2b5\uae30\uc758 \uce68\ud22c, \ucf54\uc77c\uc758 \uc774\ub3d9 \ubc0f \uc808\uc5f0\uccb4\uc758 \ub178\ud654 \uacfc\uc815\uc740 \uc624\ub79c \uc2dc\uac04 \ud6c4\uc5d0 \ubd80\uc815\uc801\uc778 \uc601\ud5a5\uc744 \ubbf8\uce60 \uac83\uc785\ub2c8\ub2e4. \uadf8\ub798\uc11c \uacf5\uc7a5 \uc784\ud384\uc2a4 \ud14c\uc2a4\ud2b8 \uc678\uc5d0\ub3c4 \uc624\uc77c \ubc0f DGA \ud14c\uc2a4\ud2b8\uc640 \uac19\uc740 \uc9c0\uc18d\uc801\uc778 \uc810\uac80\uc774 \ud544\uc694\ud569\ub2c8\ub2e4.<\/li>\n<li>\uae30\uacc4\uc801 \uad00\uc810\uc5d0\uc11c\uc758 \uc218\uba85. \ubcc0\uc555\uae30\uac00 \uc784\ud384\uc2a4 \ud14c\uc2a4\ud2b8\ub97c \ud1b5\uacfc\ud558\ub354\ub77c\ub3c4 \ub2e8\ub77d, \uacfc\ubd80\ud558 \ub610\ub294 \uc808\uc5f0\uccb4 \ub178\ud654\ub85c \uc778\ud574 \uc190\uc0c1\ub420 \uc218 \uc788\uc2b5\ub2c8\ub2e4.<\/li>\n<\/ul>\n<p>BIL\uc740 \uc784\ud53c\ub358\uc2a4 \uc218\uc900, \uc11c\uc9c0 \ubcf4\ud638\uae30 \ub4f1\uae09, \ud06c\ub9ac\ud398\uc774\uc9c0 \uac70\ub9ac, \uc811\uc9c0 \uc720\ud615 \ubc0f \ud14c\uc2a4\ud2b8 \ud504\ub85c\uadf8\ub7a8\uc744 \ud3ec\ud568\ud558\ub294 \uc77c\uad00\ub41c \uc138\ud2b8\uc758 \uc694\uc18c \uc911 \ud558\ub098\uc5ec\uc57c \ud558\uba70, \ubd88\uc0ac\uc758 \uc9c0\ud45c\uac00 \uc544\ub2c8\ub77c\ub294 \uc810\uc744 \uae30\uc5b5\ud558\ub294 \uac83\uc774 \uc911\uc694\ud569\ub2c8\ub2e4.<\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-11428\" src=\"https:\/\/subian-electric.com\/wp-content\/uploads\/2026\/09\/BIL-and-Insulation-Coordination.webp\" alt=\"BIL \ubc0f \uc808\uc5f0 \uc870\uc815\" width=\"1448\" height=\"1086\" \/><\/p>\n<h2>BIL \ubc0f \uc808\uc5f0 \uc870\uc815<\/h2>\n<p>\uc808\uc5f0 \uc870\uc815\uc758 \uac1c\ub150\uc740 \ubcc0\uc555\uae30\uac00 \ubc1b\ub294 \uc11c\uc9c0\uc758 \uc601\ud5a5\uc744 \uacac\ub51c \uc218 \uc788\ub3c4\ub85d \ud558\ub294 \uac83\uc73c\ub85c \uc815\uc758\ub420 \uc218 \uc788\uc2b5\ub2c8\ub2e4. \uae30\uc874 \uc811\uadfc \ubc29\uc2dd(IEC 60071-2)\uc5d0 \ub530\ub974\uba74, \uc7a5\ube44\uc758 \uc808\uc5f0 \uc218\uc900(BIL)\uc740 \ubcf4\ud638 \uc7a5\uce58(\uc11c\uc9c0 \ubcf4\ud638\uae30) \uc218\uc900\ubcf4\ub2e4 \ucd5c\uc18c 20% \uc774\uc0c1\uc774\uc5b4\uc57c \ud569\ub2c8\ub2e4. \uc608\ub97c \ub4e4\uc5b4, 145 kV \uc124\uce58\uc640 \uc815\uaca9 \uc804\ub958 10 kA\uc758 ZnO \uc11c\uc9c0 \ubcf4\ud638\uae30\uc5d0\uc11c \uc794\uc5ec \uc804\uc555\uc774 400 kV\uc778 \uacbd\uc6b0, \ubd80\uc2f1(\ubc0f \uc7a5\ube44)\uc758 BIL\uc740 \ucd5c\uc18c 480 kV\uc774\uc5b4\uc57c \ud558\ubbc0\ub85c \ud45c\uc900 550 kV \uc218\uc900\uc774 \uc801\uc6a9\ub418\uc5b4\uc57c \ud569\ub2c8\ub2e4. \uc808\uc5f0 \uc218\uc900\uc774 \uc694\uad6c \uc0ac\ud56d\uc744 \ucda9\uc871\ud558\uc9c0 \uc54a\uc73c\uba74 BIL \uac12\uc744 \uc99d\uac00\uc2dc\ud0a4\uac70\ub098 \uc11c\uc9c0 \ubcf4\ud638\uae30\ub97c \uc7a5\ube44\uc5d0 \ub354 \uac00\uae5d\uac8c \ubc30\uce58\ud574\uc57c \ud569\ub2c8\ub2e4.<\/p>\n<p>\ubd80\uc2f1\ub3c4 \ub3d9\uc77c\ud55c \uc808\uc5f0 \uc870\uc815\uc5d0 \ud3ec\ud568\ub429\ub2c8\ub2e4. \ubd80\uc2f1 BIL\uc740 \uc5f0\uacb0\ub41c \uad8c\uc120\uc758 BIL\uacfc \uac19\uac70\ub098 \ucee4\uc57c \ud558\uba70, \uadf8\ub807\uc9c0 \uc54a\uc73c\uba74 \uc804\uccb4 \uccb4\uc778\uc758 \uac00\uc7a5 \uc57d\ud55c \uc694\uc18c\uac00 \ub429\ub2c8\ub2e4. \ub530\ub77c\uc11c \uc774\ub7ec\ud55c \uc7a5\uce58(\ubcc0\uc555\uae30, \ubd80\uc2f1, \uc11c\uc9c0 \ubcf4\ud638\uae30)\uc758 \ubaa8\ub4e0 \uc2dc\ud2b8\uc5d0\ub294 BIL\uc774 \ud3ec\ud568\ub418\uc5b4\uc57c \ud558\uba70, BIL \uac12\uc740 \ud504\ub85c\uc138\uc2a4\uc5d0 \ucc38\uc5ec\ud558\ub294 \ubaa8\ub4e0 \uc7a5\ube44\uc5d0\uc11c \ub3d9\uc77c\ud574\uc57c \ud569\ub2c8\ub2e4. \ubcc0\uc555\uae30\uc640 \uadf8 \uc561\uc138\uc11c\ub9ac\ub97c \uad6c\ub9e4\ud560 \ub54c, \ud558\ub098\uc758 \ubb38\uc11c\uc5d0\uc11c \uc870\uc815\ub41c \uc784\ud384\uc2a4 \uc218\uc900\uc744 \uc694\uccad\ud558\ub294 \uac83\uc740 \uc870\uc815\ub41c \uc124\uce58\uc640 \ubbf8\ub798\uc758 \uc2e4\ud328 \uac04\uc758 \ucc28\uc774\uc785\ub2c8\ub2e4. <a href=\"\/ko\/product\/distribution-transformer\/\">\ubc30\uc804 \ubcc0\uc555\uae30 \uc81c\ud488 \ubc94\uc704<\/a> \uac01 \uc804\uc555 \ud074\ub798\uc2a4\uc5d0 \ub300\ud574 \uc0ac\uc6a9\ud560 \uc218 \uc788\ub294 \ud45c\uc900 BIL \uc635\uc158\uc744 \ub098\uc5f4\ud569\ub2c8\ub2e4.<\/p>\n<h2>\uc790\uc8fc \ubb3b\ub294 \uc9c8\ubb38<\/h2>\n<h3>\ubcc0\uc555\uae30\uc758 \uae30\ubcf8 \uc808\uc5f0 \uc218\uc900(BIL)\uc740 \ubb34\uc5c7\uc785\ub2c8\uae4c?<\/h3>\n<p>BIL\uc740 \ubcc0\uc555\uae30 \uc808\uc5f0\uc774 \ud50c\ub798\uc2dc\uc624\ubc84 \uc5c6\uc774 \uacac\ub38c\uc57c \ud558\ub294 \ud45c\uc900 \uc784\ud384\uc2a4 \ubc88\uac1c \uc804\uc555 1.2\/50 \u00b5s\uc758 \ucd5c\uace0 \uc804\uc555\uc744 \uc758\ubbf8\ud569\ub2c8\ub2e4. \uc774\ub294 kV \ud53c\ud06c\ub85c \uc778\uc6a9\ub418\uba70, \uc608\ub97c \ub4e4\uc5b4 15 kV \ubc30\uc804 \ubcc0\uc555\uae30\uc758 BIL\uc740 95 kV\uc774\uace0, 69 kV \ubcc0\uc555\uae30\uc758 \uacbd\uc6b0 350 kV\uc5ec\uc57c \ud569\ub2c8\ub2e4. \uadf8 \uc815\uc758\/\uc2dc\ud5d8\uc740 IEEE\/ANSI C57.12.00\/C57.12.90 (\ub610\ub294 IEC 60076-3)\uc5d0 \ub530\ub77c \uba85\uc2dc\ub429\ub2c8\ub2e4.<\/p>\n<h3>\uae30\ubcf8 \uc808\uc5f0 \uc218\uc900(BIL)\uc758 \uc815\uc758\ub294 \ubb34\uc5c7\uc785\ub2c8\uae4c?<\/h3>\n<p>\uae30\ubcf8 \uc808\uc5f0 \uc218\uc900\uc740 \uc784\ud384\uc2a4 \uc804\uc555\uc5d0\uc11c\uc758 \ud5c8\uc6a9\uce58\ub85c, \uc808\uc5f0 \uc2dc\uc2a4\ud15c\uc774 \uacac\ub38c\uc57c \ud558\ub294 \ucd5c\uace0 \uc804\uc555(\uc989, BIL \uc218\uc900)\uc744 \uc758\ubbf8\ud569\ub2c8\ub2e4. \uc774\ub294 \uc7a5\ube44\uc758 \uacf5\uc7a5 \ud14c\uc2a4\ud2b8\ub97c \ub098\ud0c0\ub0b4\uac70\ub098 \uc804\uc555 \ud074\ub798\uc2a4\uc758 \uc808\uc5f0 \uc218\uc900 \ubaa9\ub85d\uc5d0\uc11c \ud2b9\uc815 \uac12\uc744 \ub098\ud0c0\ub0c5\ub2c8\ub2e4.<\/p>\n<h3>BIL\uacfc SIL\uc740 \ubb34\uc5c7\uc785\ub2c8\uae4c?<\/h3>\n<p>BIL\uc740 \uc784\ud384\uc2a4 \uc808\uc5f0 \uc218\uc900(\ubc88\uac1c \uc218\uc900)\uc744 \uc758\ubbf8\ud558\uba70, \ud53c\ud06c\uc758 kV \uc218\uc900\uc744 \ub098\ud0c0\ub0c5\ub2c8\ub2e4. \ubcc0\uc555\uae30\uc640 \uad00\ub828\ud558\uc5ec, SPL\uc740 \uc2a4\uc704\uce6d \uc218\uc900\uc744 \uc758\ubbf8\ud558\uba70, \uc774\ub294 \uc77c\ubc18\uc801\uc73c\ub85c \uace0\uc804\uc555(345 kV \uc774\uc0c1)\uc5d0\uc11c \ubc1c\uc0dd\ud558\ub294 \uae34 \ud30c\ud615\uc758 \ub290\ub9b0 \uc2a4\uc704\uce6d \uc11c\uc9c0\uc5d0 \uc801\uc6a9\ub429\ub2c8\ub2e4. \ub450 \uc6a9\uc5b4\ub294 \uc808\uc5f0 \uc870\uc815\uc744 \uace0\ub824\ud558\ub294 \ub370 \uc0ac\uc6a9\ub418\ubbc0\ub85c \uc720\uc0ac\ud558\uc9c0\ub9cc, \uc11c\ub85c \ub2e4\ub978 \uc0c1\ud669\uc744 \ub2e4\ub8f9\ub2c8\ub2e4: BIL\uc740 \uace0\uc804\uc555 \uc2a4\ud30c\uc774\ud06c\uc5d0 \ub300\ud55c \uac83\uc774\uace0, SIL\uc740 \ub290\ub9b0 \uc2a4\uc704\uce6d\uc5d0 \ub300\ud55c \uac83\uc785\ub2c8\ub2e4.<\/p>\n<h3>\ucd5c\uc18c \uba54\uac70 \uac12\uc774\ub780 \ubb34\uc5c7\uc785\ub2c8\uae4c?<\/h3>\n<p>\uc5c4\uaca9\ud55c \ucd5c\uc18c\uac12\uc740 \uc5c6\uc9c0\ub9cc, \uc2e4\uc81c\ub85c \ubcc0\uc555\uae30\uc5d0\uc11c \uc815\uaca9 \uc804\uc555(kV)\ub2f9 \uc57d 1 M\u03a9\uc758 \uc808\uc5f0 \uc800\ud56d\uc774 \ud544\uc694\ud569\ub2c8\ub2e4(\ub610\ub294 2500V \uc2dc\ud5d8 \uc804\uc555 \uc774\ud558\uc758 \ubc30\uc804 \ubcc0\uc555\uae30\uc5d0\ub294 \uc57d 100 M\u03a9). \uce21\uc815 \uc2dc \uac00\uc7a5 \uc911\uc694\ud55c \uc694\uc18c\ub294 \uac12 \uc790\uccb4\ubcf4\ub2e4 \uac12\uc758 \ucd94\uc138\uc785\ub2c8\ub2e4.<\/p>\n<h2>\ucc38\uace0 \ubb38\ud5cc<\/h2>\n<ul>\n<li><a href=\"https:\/\/grouper.ieee.org\/groups\/transformers\/subcommittees\/dielectric_test\/C57.12.00_tables\/C57.12.00TestTables1&amp;2.pdf\" rel=\"nofollow noopener\" target=\"_blank\">IEEE C57.12.00 \uc2dc\ud5d8 \ud45c \u2014 \ubc30\uc804 \ubc0f \uc804\ub825 \ubcc0\uc555\uae30 \uc808\uc5f0 \uc218\uc900<\/a><\/li>\n<li><a href=\"https:\/\/www.eaton.com\/content\/dam\/eaton\/products\/medium-voltage-power-distribution-control-systems\/cooper-power-series-transformers\/functional-specification-for-three-phase-substation-distribution-transformers-300-12000-kva-ps202005en.pdf\" rel=\"nofollow noopener\" target=\"_blank\">Eaton \u2014 \ubcc0\uc804\uc18c \ubcc0\uc555\uae30 \uc0ac\uc591 (\uc804\uc555 \ubc0f BIL \ud45c)<\/a><\/li>\n<li><a href=\"https:\/\/ziyaopower.com\/en\/knowledge\/transformer-bushing-selection\" rel=\"nofollow noopener\" target=\"_blank\">Ziyao Power \u2014 \ubd80\uc2f1 \uc120\ud0dd \ubc0f BIL \uc870\uc815 \uac00\uc774\ub4dc<\/a><\/li>\n<li><a href=\"https:\/\/www.saso.gov.sa\/ar\/Laws-And-Regulations\/Technical_regulations\/Documents\/SASO-IEEE-C57-2018-E.pdf\" rel=\"nofollow noopener\" target=\"_blank\">IEEE C57 \u2014 \uacc4\uce21 \ubcc0\uc555\uae30 BIL \ubc0f \uc720\uc804\uccb4 \uc2dc\ud5d8 \ud45c<\/a><\/li>\n<li><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/62860\" rel=\"nofollow noopener\" target=\"_blank\">IEC 60076-3 \u2014 \uc804\ub825 \ubcc0\uc555\uae30: \uc808\uc5f0 \uc218\uc900, \uc720\uc804\uccb4 \uc2dc\ud5d8<\/a><\/li>\n<\/ul>\n<h2>\uacb0\ub860<\/h2>\n<p>\uae30\ubcf8 \uc808\uc5f0 \uc218\uc900\uc740 \ubcc0\uc555\uae30\uc758 \ub099\ub8b0 \ubc0f \uc11c\uc9c0 \uad6c\uc870\ub97c \ud3ec\ud568\ud558\uba70, \ud2b9\uc815 \ucd5c\ub300 \uc804\uc555 \uac12\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4: 15 kV \ud074\ub798\uc2a4 \uad6c\uc870 \u2013 95 kV, 69 kV \ud074\ub798\uc2a4 \u2013 350 kV, 500 kV \ud074\ub798\uc2a4 \uad6c\uc870 \u2013 1,675 kV; \uc774\ub7ec\ud55c \uac12\uc740 \uc808\uc5f0 \uad6c\uc870\uc758 \uac15\ub3c4\ub97c \ub098\ud0c0\ub0c5\ub2c8\ub2e4. \uc774 \uac1c\ub150\uc758 \ubcf8\uc9c8\uc740 \uc870\uc815\uc5d0 \uc788\uc73c\uba70, \uc989 BIL\uc744 \uc804\uc555 \ud074\ub798\uc2a4\uc5d0 \ub9de\ucd94\uace0, \ub450\uaebc\uc6b4 \ubcf4\ud638 \uc5ec\uc720\uc640 \ub099\ub8b0 \uc601\ud5a5\uc744 \uace0\ub824\ud558\uc5ec \ubcc0\uc555\uae30\uc758 BIL\uc744 \ud3c9\uac00\ud558\uba70, \ubcf4\ud638 \uc5ec\uc720\ub97c 20% \uc774\uc0c1\uc73c\ub85c \uc720\uc9c0\ud574\uc57c \ud569\ub2c8\ub2e4. \uadf8\ub7ec\ub098 BIL\uc758 \ub3c4\uc6c0\uc73c\ub85c \ud574\uacb0\ud560 \uc218 \uc788\ub294 \uac83\uc740 \uc624\uc9c1 \uc784\ud384\uc2a4 \ubb38\uc81c\ubfd0\uc784\uc744 \uc720\uc758\ud574\uc57c \ud569\ub2c8\ub2e4.<\/p>","protected":false},"excerpt":{"rendered":"<p>If you pick up and go through any transformer specification sheet, you are bound to find information regarding what is referred to as Basic Insulation Level, or BIL for short \u2014 e.g. &#8220;BIL: 95 kV&#8221; or &#8220;BIL: 150 kV.&#8221; If you have had any query regarding these ratings or been puzzled by the fact that [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":11426,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-11424","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/subian-electric.com\/ko\/wp-json\/wp\/v2\/posts\/11424","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/subian-electric.com\/ko\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/subian-electric.com\/ko\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/subian-electric.com\/ko\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/subian-electric.com\/ko\/wp-json\/wp\/v2\/comments?post=11424"}],"version-history":[{"count":4,"href":"https:\/\/subian-electric.com\/ko\/wp-json\/wp\/v2\/posts\/11424\/revisions"}],"predecessor-version":[{"id":11431,"href":"https:\/\/subian-electric.com\/ko\/wp-json\/wp\/v2\/posts\/11424\/revisions\/11431"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/subian-electric.com\/ko\/wp-json\/wp\/v2\/media\/11426"}],"wp:attachment":[{"href":"https:\/\/subian-electric.com\/ko\/wp-json\/wp\/v2\/media?parent=11424"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/subian-electric.com\/ko\/wp-json\/wp\/v2\/categories?post=11424"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/subian-electric.com\/ko\/wp-json\/wp\/v2\/tags?post=11424"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}