COMPANY PROFILE

Current Transformer In Switchgear Manufacturers – Integrated CT Supply

Subian Electric manufactures switchgear with integrated current transformers – KYN28A-12 switchgear and XGN15-12 / HXGN15-12 ring main units with CTs for metering and protection. Subian’s 50,000-square-metre factory in Xuzhou, Jiangsu, China, has served utilities in 50+ countries since 2019.

As a factory-direct manufacturer and supplier, Subian provides switchgear with correctly rated, factory-tested current transformers – removing the interface risk of buying CTs separately.

Send your switchgear configuration and CT requirements. Subian’s export team will respond with a quotation and drawings.

Subian Electric ISO9001 CE and UL product certification marks
Switchgear with current transformers assembly at Subian
Factory-Direct Manufacturer Since 2019 · 50,000m² · 350+ Staff
50,000m²Manufacturing Base
CTIntegrated Type
350+Employees
50+Countries Served
OEM/ODMSupport
WholesaleSupply

Switchgear With Current Transformers Manufactured by Subian

KYN28A-12 withdrawable switchgear and ring main units with integrated current transformers for metering, protection and control, tested per IEC 62271.

What Is a Current Transformer in Switchgear?

A current transformer (CT) in switchgear steps down high circuit current to a safe level for protection relays and metering instruments. Correct rating and accuracy are essential for reliable protection and billing.

CTs are integrated into the switchgear busbars and cable connections during manufacture, so the rating, accuracy class and burden are matched to the protection scheme from day one.

LMZK Wound Current Transformer300/5a manufactured by Subian Electric
LSY-10 transformer Integrated CT manufactured by Subian Electric

What Buyers Check Before Ordering

  • Integrated CTs – metering and protection CTs built into switchgear.
  • Correctly rated – ratio, accuracy class and burden matched to your scheme.
  • Factory tested – CT polarity and ratio verified with the panel.
  • 50,000m² factory – in-house switchgear assembly and testing.
  • 350+ employees – engineering, quality and export teams.
  • OEM / ODM & wholesale – custom branding, packaging and volume supply.

Main Types of Current Transformers in Switchgear

Subian integrates two CT types into switchgear:

Metering CT - Current Transformer In Switchgear

Metering CT

Metering

Accurate class CTs for energy metering and instrumentation.


Class 0.5 or 0.2S / IEC 61869-2

See the range

Protection CT - Current Transformer In Switchgear

Protection CT

Protection

Class 5P / 10P CTs for relay protection schemes.


5P10 or 5P20 / IEC 61869-2

See the range

Switchgear CT Specifications

Parameter Specification
Voltage 12 kV / 40.5 kV
Ratio Per protection / metering scheme
Accuracy class 0.2S – 5P20
Frequency 50/60 Hz
Switchgear KYN28A-12 / XGN15-12
Standard IEC 62271 / GB 3906

How to Compare Current Transformer In Switchgear Suppliers

Quotations for this equipment often look identical on the first page. The difference sits in what is attached behind the number, and in the three or four lines that decide the installed cost rather than the purchase price.

What to compareWhat a thin quotation leaves outWhat to ask for
Enclosure and IP ratingIndoor assumedIP30 to IP54, and whether the room is dusty or washdown
Cable entryBottom entry onlyTop or bottom entry, gland plate size and the bending radius
Busbar materialCopper impliedCopper or aluminium, the cross-section and the plating
MeteringA space for a meterCT ratio, meter class and whether a communication port is required
PaintingA colour codePre-treatment, primer and topcoat thickness in microns
Spares and labelsNothing beyond the panelSpare fuses, engraved labels and the schematic set

Buyers who compare on price alone usually discover the gap at commissioning. The six lines above are the ones that decide whether the unit or the panel can be energised without site work. OEM and ODM supply is available where the nameplate, manual and packing have to carry a different brand.

Current Transformer In Switchgear Standards Buyers Ask For

The purchase specification decides the insulation level, the enclosure test and the nameplate data. These are the standards buyers normally name in the enquiry.

StandardWhat it coversWhen it is asked for
IEC 61439-2LV assemblies: design verification and routine testAny LV panel for IEC markets
IEC 62271-200MV metal-enclosed switchgear up to 52 kVRMU and KYN-type panels
IEC 62271-100High-voltage circuit breakersVacuum and SF6 breakers
IEC 60529Degrees of protection (IP code)Outdoor and dusty installations
IEC 60947-2Low-voltage circuit breakersDevice selection inside the panel
GB 7251.1 / GB 3906Chinese equivalents for LV and MV assembliesDomestic projects and CNAS reports

Where two standards conflict, the purchase specification wins and the conflict is recorded on the drawing before production. Type test reports are issued against the model, so ask for the report that names the rating you are buying.

Switchgear With CT Manufacturing at Subian’s 50,000 m² Factory

From busbar assembly to CT mounting, wiring and testing – every panel is built and tested at Subian’s Xuzhou facility with CT polarity verified.

Switchgear With Current Transformer Factory Price – Request a Quote

Send your specification, voltage level, capacity and quantity. Subian’s export team will respond with factory pricing, lead time and drawings for approval.

OEM/ODM & Wholesale Switchgear CT Supply

Panel builders and distributors can brand or resell switchgear with custom nameplates and documentation.

OEM ODM manufacturing service

OEM / ODM

Factory-Direct

Custom branding, packaging and product variants built on Subian’s standard platforms – from a nameplate to full product design.


Custom nameplate · Custom packaging · Full test docs

Wholesale supply with factory pricing

Wholesale Supply

Volume Pricing

Factory pricing with flexible container quantities, mixed models per container and reliable global shipping for volume buyers and importers.


Container MOQ · Mixed models · Global shipping

Distributor support with account management

Distributor Support

Channel Partners

Dedicated account management, technical documentation and priority production for distributors and project clients.


Account manager · Sales material · Priority lead times

Integrated CTs vs Separate CT Purchase

Buying CTs separately risks wrong ratios, polarity errors and installation delays. Integrated CTs are rated, mounted and tested with the panel – one supplier, one test record.

For utilities and panel builders, integrated supply simplifies procurement and commissioning.

Comparison and selection guide
Manufacturers and suppliers in China

Choosing a Current Transformer In Switchgear Manufacturer

Verify the manufacturer’s switchgear test capability and CT rating engineering. Correct CT selection is what makes protection schemes work.

Subian Electric offers a 50,000m² factory, 350+ employees, ISO9001, CE and UL certification and export to 50+ countries.

Send your switchgear configuration and CT requirements – Subian confirms the design before production.

Certifications & Quality Assurance

Subian’s switchgear with CTs is produced under ISO9001, ISO14001 and ISO45001 management systems, with CE and UL certification and type test reports.

Product Certifications

FAQs

Current Transformer In Switchgear FAQ

Common questions about current transformers in switchgear and factory sourcing.

What is a current transformer used for?
It steps high circuit current down to a safe level for protection relays and metering instruments.
What CT ratios and accuracy classes do you supply?
Ratios follow your protection and metering scheme, with accuracy classes from 0.2S for metering to 5P20 for protection.
Can CTs be added to existing switchgear?
For new panels Subian integrates CTs during manufacture; for existing panels, retrofit depends on the design – Subian’s engineers can advise.
How is CT polarity verified?
Polarity and ratio are tested with the panel in the factory, and test records are supplied.
What is the minimum order quantity?
Single panels are available; project volumes receive the best factory pricing.
What are your delivery terms?
FOB / CIF / DDP terms are available, with lead times confirmed against your project schedule.
Can Current Transformer In Switchgear be supplied as a complete package?
Yes. The package can include the incoming panel, feeders, motor control, capacitor compensation, metering and the interconnecting busbar, factory wired and tested as one assembly so site work is limited to cables and commissioning.
What is needed to quote Current Transformer In Switchgear?
The single-line diagram, the short-circuit level, the incoming and outgoing ratings, the IP rating and the metering requirement. A BOQ is enough to start; the SLD fixes the price.

Contact Subian

Need the Right Specification?

Tell Subian your target market, product type, quantity and technical requirements. Subian’s team will help you identify a suitable configuration for your project.

Contact Form Demo
Your inquiry is sent directly to Subian’s export sales team.