The HXGN15-12 fixed-type metal-enclosed ring main unit provides reliable load switching and protection for 12kV urban distribution networks. Equipped with compressed-air or vacuum load switches and spring mechanisms, it is manufactured by Subian Electric for urban grid projects. Supplied directly from our manufacturing base in Xuzhou, China, this product is available for distributors and OEM customers worldwide.

HXGN15-12 — Ring Main Unit (RMU)12 kV · 50 Hz · Indoor
Ring Network Ready
Load + Vacuum Switch
12 kV

Key Specifications

  • Rated Voltage — AC 12 kV, 50 Hz
  • Application — Urban distribution and ring networks
  • Switching — Compressed-air / vacuum load switch
  • Mechanism — Spring operated, manual or electric
  • Options — Isolation switch, VS1 fixed circuit breaker
  • Mounting — Indoor; installable in box substations
  • Standards — IEC 62271 / GB 3906

Product Overview

Metal-Enclosed Ring Main Unit from a Trusted Power Equipment Factory

HXGN15-12 tabular type metal-covered ring network switchgear refers to a novel kind of device for high voltage specifications, designed for reconstruction and building purposes within urban electricity grids. Its main function is breaking down the load and causing short-circuit currents, playing the role of ring supply apparatus for 12 kV and 50 Hz voltage networks as well as the end-user devices installed in box-type substations.

metal-enclosed ring network switchgear--HXGN15-12 AC — Applications & circuit protection applications

Applications & circuit protection

HXGN15-12 ring main units enable switching and protection in urban distribution grids and supply points.

  • Urban distribution grids: Ring distribution and protection.
  • Industrial and mining: Distribution feeders.
  • High-rise buildings: Compact distribution of MV.
  • Box substations: MV on-board distribution.
metal-enclosed ring network switchgear--HXGN15-12 AC construction and operating reliability

Construction & operating reliability

The spring mechanism can be utilized in either manual or powered form, and there are potential isolation and VS1 fixed circuit breaker applications.

  • It interrupts load current and short circuit current.
  • With compressed air or vacuum load switch options available.
  • This has a spring mechanism and can be operated either by hand or electrically.
  • There are isolation switch and VS1 circuit breaker options available.
  • Provides a compact metal enclosure type for fixed type.

Technical Parameter

Parameter Value
Rated voltage AC 12 kV
Rated frequency 50 Hz
Application Ring network supply, distribution and protection
Load switch Compressed-air / vacuum type
Operating mechanism Spring, manual or electric
Mounting Indoor, box substation compatible
Standard IEC 62271 / GB 3906

Panel Cost Factors & Getting a Quote

The price of a Ring Main Unit controller is determined by its current rating, breaking capacity, type of remaining circuitry, housing and equipment. We give the offer based on a customer’s single-line model and the volume price for container orders.

  • Quote for submission based on SLD and panel layout
  • Prices reflecting the volume of purchases for the distributor
  • Price for delivery and certificate per order

Panel Connection Guide

Connect the power cables at the terminal busbars marked and fix control cable according to the given schematic. Mechanical interlocks need to be verified before the system is powered.

  • Power and control terminals are properly marked
  • Interlock verification must be done before being powered up
  • Connection diagram is provided along with the panel

Compare Switchgear Configurations

Select the configuration that fits your project:

Feature This Panel Alternative
Voltage As specified Other MV/LV classes available
Current Per model Higher or lower rated current
Mounting Fixed / withdrawable per model Ring main or feeder arrangement
Protection Per project relay scheme Custom protection functions
Best for Distribution and control Substation or industrial feeders

Export Markets & Country Compatibility

The Ring Main Unit is delivered to distribution and industrial projects in Southeast Asia, the Middle East, Africa, Latin America and South Asia. The configuration of the panels meets country standards in terms of voltage, frequency and protection, with the certification confirmed per region.

Panel Dimensions, Weight & Packing

The size and weight of panel depend on both its arrangement and current rating. Standard LV panels have a width of 600-1000 mm, a depth of 600-1000 mm and a height of 1800-2200 mm. Dimensions and weight are verified through the approval drawing before transportation in an upright position.

  • Demention and weight confirmed according to approval drawings
  • Panels are prepared for transportation with busbar protection
  • Lifting and transport arrangements are specified in the order

metal-enclosed ring network switchgear--HXGN15-12 AC standards and certifications

Standards & certifications

Manufactured according to IEC 62271 and GB 3906, the device may be supplied together with type-test documentation for grid project acceptance.

  • Design standard: IEC 62271 / GB 3906.
  • Load breaking and short circuit making confirmed.
  • Type-test reports available.
  • Documentation for approval of project.
metal-enclosed ring network switchgear--HXGN15-12 AC OEM and B2B supply support

OEM & B2B supply support

Subian Electric serves as a specialist in producing power products and supplying pwer brackets for urban processes, construction organizations and suppliers of power materials.

If you need a certain configuration or a particular type of switch, let us know about the specifications of your network and amount of RMUs.

  • Samples and design drafts available upon request.
  • Purchasing in a flexible volume is possible.
  • OEM/ODM is supported.
  • Marking and packing are done by us.
  • Technical documentation and certification will also be provided at your request.


Request a Quote


Frequently Asked Questions

What is a ring main unit?

An RMU (ring main unit) is mainly utilized for switching and protection of MV feeders in ring-type distribution networks using various kind of load switches and breakers and fuses.

What voltage is this unit rated for?

The voltage rating of HXGN15-12 is 12kV AC 50Hz.

What switching options are available?

Two options are available in this regard i.e. compressed air load switch or vacuum load switch, with other options of isolation switch and circuit breaker VS1.

Can it be installed in box substations?

Yes, it can be used in the box substations as it is suitable for indoor installation.

Subian Electric Power manufacturing facility in Xuzhou
Manufacturing Base

SF6-Insulated Switchgear Production in Xuzhou

Subian's Xuzhou facility includes a clean assembly area for SF6-insulated ring main units and switchgear, with leak-test and gas-filling stations. Sealed tank units are assembled, filled and tested in-house. In-house production and testing of the Ring Main Unit follow the same controlled process at this facility. Drawings, test records and certificates support approvals and maintenance. Ratings, protection and layout follow your project requirements.
  • Sealed-tank RMU assembly, gas filling and leak testing at our plant
  • Technical support for distributors, utilities and contractors
Factory Facilities

Clean Assembly and Gas Filling Areas

The images show the clean switchgear assembly area, SF6 filling and leak-test stations, and customer inspection activities at Subian's Xuzhou facility. The Ring Main Unit supplied on this page is manufactured, tested and quality-checked at this site. Secondary wiring checked against the schematic. Insulation and operation verified.
Subian SF6 switchgear production workshop
AssemblyFrames, busbars and components assembled per drawing.
SF6 gas filling area inside the Subian factory
Component fittingBreakers and devices installed and torqued.
International customer inspecting SF6 switchgear at the factory
InspectionBuyer inspection welcomed.
Manufacturing Process

Tank Assembly, Gas Filling and Testing

SF6 switchgear production follows: tank and busbar assembly, mechanism fitting, evacuation and gas filling, leak checking, and routine testing of operation and insulation. Manufacturing of the Ring Main Unit follows the confirmed specification, with checks recorded at each relevant stage. Panel configuration, busbar rating and protection can be arranged to match your single-line diagram. Verified mechanisms and contact systems support dependable operation over many operations.
  • Internal components assembled in a controlled-clean environment
  • Tanks evacuated and filled with SF6 to the specified pressure
  • Leak checks and routine tests recorded
Subian switchgear assembly production line
Send Your SLD
Subian switchgear assembly process
Quotation
Technician fitting a switchgear operating mechanism
TestingInsulation and operation verified.

Leak Tightness and Sealed Operation

Sealed tank units are checked for gas tightness, and operating mechanisms are verified for correct close/open performance before routine testing. Yes, panel layout follows your requirements and approved drawings. Panels are manufactured and tested to the relevant IEC/GB standards for the voltage class. General arrangement and wiring diagrams are provided for approval.
Subian switchgear tank detail
Share your single-line diagram and requirements.Receive pricing and drawings.
Visitors at the Subian power equipment booth
Subian booth at an international electrical exhibition
Subian team meeting a customer at an electrical exhibition
Customer visiting the Subian transformer booth
Subian international exhibition team
Subian sales representative discussing a project with a visitor
Visitors at the Subian power equipment booth
Subian booth at an international electrical exhibition
Customer Meetings

SF6 Switchgear Sourcing Discussions

Our team discusses sealed-tank RMU configurations, switch ratings and delivery requirements with distributors and utilities at electrical exhibitions. Dependable distribution for commercial projects. Incoming and feeder panels for substations. Motor and load control for industrial facilities.
Contact Our Export Team
Product Documentation

SF6 Switchgear Certificates and Test Records

Type-test reports, routine test records and certificates for SF6-insulated switchgear can be confirmed according to model and destination market. For the Ring Main Unit, certificates, type-test reports and routine test records can be confirmed before ordering. The complete panel with your configured ratings and protection, plus drawings and test documents. By configuration, ratings and protection scheme. We quote against your single-line diagram with volume terms for projects.
Example switchgear conformity certificate
Conformity documents
Example switchgear type test report
Type-test reports
Packed Subian power equipment prepared for delivery
Packing and shipmentSF6 switchgear is packed upright with gas pressure preserved and mechanisms protected.
Product Inquiry

Request Product Information and Pricing

Please provide the product type, rated voltage, capacity, quantity, applicable standard, delivery country and required delivery date. We will reply with a quotation or a list of points requiring confirmation.
  • Product selection and technical clarification
  • OEM, ODM and private-label requirements
  • Quantity, packing and delivery planning

Project and Product Requirements

Fields marked with * are required.
Subian Product Inquiry