COMPANY PROFILE

High Voltage Current Transformer Manufacturers – HV Metering & Protection

Subian Electric manufactures high voltage current transformers for metering and protection in substations and switchgear, from its 50,000-square-metre factory in Xuzhou, Jiangsu, China. Subian’s 350+ employees have served utilities in 50+ countries since 2019.

As a factory-direct manufacturer and supplier, Subian supplies HV CTs with correct ratios, accuracy classes and burden, factory-tested and fully documented.

Send your voltage class, ratio and accuracy requirements. Subian’s export team will respond with a quotation and technical data.

Subian Electric ISO9001 CE and UL product certification marks
High voltage current transformer production at Subian
Factory-Direct Manufacturer Since 2019 · 50,000m² · 350+ Staff
50,000m²Manufacturing Base
HV CTVoltage Class
350+Employees
50+Countries Served
OEM/ODMSupport
WholesaleSupply

High Voltage Current Transformers Manufactured by Subian

HV current transformers for 10 kV to 35 kV class metering and protection, supplied loose or integrated into switchgear and substation packages.

What Is a High Voltage Current Transformer?

A high voltage current transformer measures circuit current at medium voltage levels, feeding proportional signals to protection relays and meters. Its insulation system must withstand the full line voltage.

HV CTs are specified for substations, switchgear and transmission monitoring – with accuracy and saturation performance that decide protection reliability.

LXK high voltage zero sequence manufactured by Subian Electric
LMZK Wound Current Transformer300/5a manufactured by Subian Electric

What Buyers Check Before Ordering

  • 10-35 kV class – HV CTs for substation and switchgear duty.
  • Metering & protection – accuracy classes to 0.2S / 5P20.
  • Factory tested – ratio, polarity and insulation verified.
  • 50,000m² factory – in-house winding, casting and testing.
  • 350+ employees – engineering, quality and export teams.
  • OEM / ODM & wholesale – custom branding, packaging and volume supply.

Main Types of High Voltage Current Transformers

Subian supplies two HV CT types:

Metering CT - High Voltage Current Transformer

Metering CT

Metering

High-accuracy units for energy measurement and billing.


Class 0.5 or 0.2S / IEC 61869-2

See the range

Protection CT - High Voltage Current Transformer

Protection CT

Protection

Saturated-characteristic units for relay protection schemes.


5P10 or 5P20 / IEC 61869-2

See the range

High Voltage Current Transformer Specifications

Parameter Specification
Rated voltage 10 kV / 35 kV class
Primary current Per scheme (50 A – 2000 A)
Accuracy 0.2S – 5P20
Insulation Cast resin / oil immersed
Frequency 50/60 Hz
Standard IEC 61869

How to Compare High Voltage Current Transformer Suppliers

Quotations for this equipment often look identical on the first page. The difference sits in what is attached behind the number, and in the three or four lines that decide the installed cost rather than the purchase price.

What to compareWhat a thin quotation leaves outWhat to ask for
ApplicationA generic CT or PTMetering, protection or both, and the relay it feeds
BurdenIgnoredTotal burden including cable and relay, in VA
Short-circuit ratingNot statedRated short-time thermal current and the dynamic rating
EnvironmentIndoor assumedIndoor or outdoor, pollution level and the creepage distance
Secondary terminalsA terminal boxTerminal arrangement, sealing and the shorting link
CalibrationA factory sheetCalibration certificate with the traceability chain

Buyers who compare on price alone usually discover the gap at commissioning. The six lines above are the ones that decide whether the unit or the panel can be energised without site work. OEM and ODM supply is available where the nameplate, manual and packing have to carry a different brand.

High Voltage Current Transformer Standards Buyers Ask For

The purchase specification decides the insulation level, the enclosure test and the nameplate data. These are the standards buyers normally name in the enquiry.

StandardWhat it coversWhen it is asked for
IEC 61869-2Current transformersMetering and protection cores
IEC 61869-3Voltage transformersInductive VT for metering and protection
IEC 61869-1General requirementsInsulation, burden and accuracy definitions
IEC 60044-1Legacy CT standardReplacement units for older installations
IEC 60529Degrees of protectionOutdoor and polluted sites
GB 1208 / GB 1207Chinese CT and PT standardsDomestic projects and CNAS reports

Where two standards conflict, the purchase specification wins and the conflict is recorded on the drawing before production. Type test reports are issued against the model, so ask for the report that names the rating you are buying.

HV Current Transformer Manufacturing at Subian’s 50,000 m² Factory

From winding to casting, assembly and testing – every HV CT is built and tested at Subian’s Xuzhou facility with insulation and ratio verification.

High Voltage Current Transformer Factory Price – Request a Quote

Send your specification, voltage level, capacity and quantity. Subian’s export team will respond with factory pricing, lead time and drawings for approval.

OEM/ODM & Wholesale HV CT Supply

Utilities and panel builders can brand or resell HV CTs with custom nameplates and documentation.

OEM ODM manufacturing service

OEM / ODM

Factory-Direct

Custom branding, packaging and product variants built on Subian’s standard platforms – from a nameplate to full product design.


Custom nameplate · Custom packaging · Full test docs

Wholesale supply with factory pricing

Wholesale Supply

Volume Pricing

Factory pricing with flexible container quantities, mixed models per container and reliable global shipping for volume buyers and importers.


Container MOQ · Mixed models · Global shipping

Distributor support with account management

Distributor Support

Channel Partners

Dedicated account management, technical documentation and priority production for distributors and project clients.


Account manager · Sales material · Priority lead times

Cast Resin vs Oil Immersed HV Current Transformers

Cast resin CTs are maintenance-free and suit indoor and outdoor use without oil handling. Oil-immersed units suit very high voltage classes and harsh environments.

For 10-35 kV duty, cast resin is the practical standard; Subian confirms the construction with your site.

Comparison and selection guide
Manufacturers and suppliers in China

Choosing a High Voltage Current Transformer Manufacturer

Verify accuracy class test evidence and insulation quality. CT performance directly affects protection and metering accuracy.

Subian Electric offers a 50,000m² factory, 350+ employees, ISO9001, CE and UL certification and export to 50+ countries.

Send your voltage class and ratio requirements – Subian confirms the design before production.

Certifications & Quality Assurance

Subian’s HV current transformers are produced under ISO9001, ISO14001 and ISO45001 management systems, with CE and UL certification and type test reports.

Product Certifications

FAQs

High Voltage Current Transformer FAQ

Answers to the questions buyers ask most about high voltage current transformers.

What is a high voltage current transformer?
It measures circuit current at medium voltage, feeding proportional signals to protection relays and meters with insulation rated for the line voltage.
What accuracy classes are available?
From 0.2S for metering to 5P20 for protection, per your scheme requirements.
What is the difference between metering and protection CTs?
Metering CTs prioritise accuracy at normal current; protection CTs are designed to saturate predictably under fault conditions.
Can HV CTs be supplied with switchgear?
Yes – integrated into switchgear panels or supplied loose with matching documentation.
What testing is done?
Ratio, polarity, insulation and accuracy tests with records supplied.
What is the minimum order quantity?
Single units are available; project volumes receive the best factory pricing.
Can High Voltage Current Transformer replace an existing unit?
Yes, provided the outline drawing, the ratio, the burden and the terminal arrangement are matched. Photograph the nameplate and the terminal box, and the replacement is built to those values so the wiring and the mounting stay unchanged.
What insulation level is used for High Voltage Current Transformer?
The rated insulation level follows the system voltage, typically 12/28/75 kV for 12 kV class and 24/50/125 kV for 24 kV class equipment. Outdoor units carry a longer creepage distance for the pollution level at site.