Product Overview
Integrated Three-Phase Current Transformer from a Leading Chinese Manufacturer
LSY-10 bar-type three-phase current transformer is a simple and compact approach to measure three-phase current in 10kV power system applications. Its use can be seen in switchgear panels, distribution cabinets, and OEM electrical devices. It can be purchased directly from factory in bulk to distributors, wholesalers and project purchasers.

Applications & circuit protection
The LSY-10 integrated CT is intended for measuring and controlling three-phase AC circuits used in the 10kV power production field.
- In MV switchgear: The measurement of currents in panels and incoming lines.
- At distribution substations: metering and protection for 10kV circuits.
- In OEM products: Integrated CT is used in packaged switchgear and skids.
- At industrial plants: monitoring of transformers, motors, and feeders.

Construction & operating reliability
With its bar-type primary design, this unit provides a straightforward and mechanically sturdy solution, whereas the integrated three-phase feature helps to save the wiring time and installation space as compared to conventional CTs, which require three devices.
- The primary bar is designed to endure high short-circuit withstand.
- An integral casing of three phases lessens the time required for installation.
- Many ratios are available from 100 A to 1,000 A.
- The secondary output can be set to 5 A or 1 A.
- The item is designed for indoor installation, 10 kV insulation class.
Technical Parameter
| Parameter | Value |
| Rated voltage | 10 kV |
| Rated primary current | 100 / 200 / 300 / 400 / 500 / 630 / 800 / 1000 A |
| Rated secondary current | 5 A or 1 A |
| Accuracy class | 0.5, 0.2S (metering); 5P, 10P (protection) |
| Rated burden | 10 / 15 / 20 / 30 VA |
| Rated frequency | 50/60 Hz |
| Insulation | Indoor, 10kV class |
| Application | Three-phase measurement, metering and protection |
Instrument Transformer Cost & Quote
Kindly provide your ratio, accuracy class, and quantity to enable a quotation for a Three-Phase Current Transformer by the factory. Volume discounts for switchgear and panel manufacturers are available.
- Quotation based on specification sheet
- OEM and Private Label are acceptable.
- Quick delivery for standard range.
CT Wiring & Secondary Connection
The three-phase current transformer displays clear primary and secondary connections. Always connect the secondary circuit to the relay or measuring device with proper polarity; the secondary circuit must never remain open while hot.
- P1/P2 and S1/S2 markings as per convention
- Polarity marking for the proper connection
- Secondary shorting facilities on request
Compare CT Options
Choose the instrument transformer that fits your scheme:
| Feature | This CT | Alternative |
| Ratio | As specified | Other ratios available |
| Accuracy | Per class | 0.2 / 0.5 / protection class |
| Insulation | Epoxy cast / oil | Indoor or outdoor design |
| Application | Metering / protection | Multi-ratio or special duty |
Export Markets & Country Compatibility
Instrument transformers are sent around the globe to switchgear manufacturers and distributors, adjusted for the ratio, precision, and specifications of each of its markets.
CT Dimensions, Weight & Packing
The weight and dimensions are based on the aspects of ratio, insulation and fitting type. Devices are made compact enough to be used for panel or cable installation; terminals are protected during transportation. Dimensions drawings come with technical specification.
- Dimensions compact for panel fitting
- Protection of terminals during transportation
- Dimensions drawing per model

Standards & certifications
In conformity with IEC 60044-1 / IEC 61869, the LSY-10 integrated current transformer is constructed. All necessary test documentation can be provided to support project approval and certification in the market.
- Designed in compliance with: IEC 60044-1 / IEC 61869 series.
- The accuracy levels for the applications of measuring and protective purposes are confirmed.
- Insulation class meets 10 kV indoor use requirements.
- The connections are appropriately marked.

OEM & B2B supply support
Subian Electric is an expert in the manufacturing of electric power equipment, supplying it to producers of switchgear and contractors on engineering procurement construction basis concerning the choice of a current transformer, sampling and quoting.
Do you differ in specification or accuracy level? Provide us with primary and secondary currents together with accuracy and quantity to be informed on appropriate configuration by our engineering team.
- Samples for testing purposes.
- Flexible batches for your projects and B2B purchases.
- OEM/ODM solutions for integration of your switchgear.
- Custom terminals, marking and packaging.
- Technical documentation.
Frequently Asked Questions
What does an integrated three-phase CT do?
It allows to measure a three-phase current using a single fixed model and converts them to a proportional secondary signal of 5A or 1A that enables metering and protection devices to work without taking up the panel space.
What ratios are available for the LSY-10?
The primary current ranges from 100A to 1000A and has either 5A or 1A output with a margin of accuracy of 0.5/0.2S or 5P/10P.
Can the LSY-10 be used in existing switchgear?
It is suitable for indoor switchgear with a voltage of 10kV that can be either used in the installation of switchgear or as a replacement of applications that require three-phase current measuring.
Do you support OEM orders?
Yes, both OEM and ODM orders are accepted. Just provide us the ratio, accuracy, burden, quantity and the market for proposals.