Request a Quote
Home / Product / outdoor pole mounted disconnect switch–40.5KV 250a
Products

outdoor pole mounted disconnect switch–40.5KV 250a

Pole-Mounted Disconnect Switch — OEM/ODM & Wholesale Supplier

This 40.5kV 250A outdoor pole-mounted disconnect switch isolates high-voltage circuits during maintenance and normal switching. Built for outdoor weather resistance, it is manufactured by Subian Electric and supplied to utilities, distributors and project buyers worldwide.

40.5kV Disconnect Switch — Pole Mounted40.5 kV · 250 A · Outdoor
40.5 kV Rated
Outdoor Weatherproof
Pole Mounted

Key Specifications

  • Rated Voltage — 40.5 kV
  • Rated Current — 250 A
  • Short-Time Withstand — 12.5 kA / 16 kA options
  • Peak Withstand — 31.5 kA / 40 kA
  • Insulation Level — 95 kV power-frequency; 185 kV impulse
  • Mounting — Outdoor pole mounted
  • Standards — IEC 62271 / GB 1985

Product Overview

Outdoor 40.5kV Pole-Mounted Disconnect Switch from a Professional Power Equipment Manufacturer

The outdoor pole-mounted disconnect switch, rated at 40.5kV and 250A, is an apparatus that creates a visible break to isolate circuits carrying high voltage in overhead distribution networks. The switch is built for continuous operation outdoors and is resistant to rain, wind and UV light.

outdoor pole mounted disconnect switch--40.5KV 250a — Applications & circuit protection applications

Applications & circuit protection

The disconnect switch is used on aerial poles and towers when isolation of circuits is necessary for maintenance, repair or operational switching.

  • Overhead distribution: Isolation of 40.5kV lines.
  • Substation feeders: Disconnect for maintenance.
  • Rural networks: Reliable and easy pole-mounted switching.
  • Utility projects: Provide grid extension and reconstruction.
outdoor pole mounted disconnect switch--40.5KV 250a construction and operating reliability

Construction & operating reliability

The elevated voltage switch employs durable porcelain insulation together with resistant components and thus operates properly for a long time in outdoor conditions.

  • High voltage insulators at up to 40.5kV for outdoor application.
  • Corrosion-proof parts that provide durability in harsh conditions.
  • Good visible separation when the switch operation is open.
  • Easy switching using lever or insulated rod.
  • Stable construction allowing easy installation for pole mounting.

Technical Parameter

Parameter Value
Rated voltage 40.5 kV
Rated current 250 A
Rated short-time withstand current 12.5 kA / 16 kA
Rated peak withstand current 31.5 kA / 40 kA
Power-frequency withstand (1 min) ~95 kV
Lightning impulse withstand ~185 kV
Mounting Outdoor pole mounted
Standard IEC 62271 / GB 1985

Breaker Cost & Quotation

Ask for pricing of Pole-Mounted Disconnect Switch. Send your rated current, breaking capacity, and number of pieces needed. Pricing based on volume is applicable to distributor and project orders.

  • We provide prompt quotes for standard ratings
  • OEM branding at no additional cost
  • Export packaging included

Breaker Wiring & Control Connection

The power terminals link the circuit and the switch; the control terminals receive opening/closing signals while auxiliary contacts are utilized. The Pole-Mounted Disconnect Switch comes with the wiring diagrams and terminal markings.

  • Main terminals identified by drawing
  • Control circuit prepared and tested
  • Auxiliary contacts available for signaling

Compare Breaker Options

Select the right breaker for your duty:

Feature This Breaker Alternative
Voltage As specified Other classes available
Breaking Per model Higher breaking on request
Mechanism Spring / magnetic per model Manual or motor operation
Mounting Indoor / outdoor per model Pole or panel mounting

Export Markets & Country Compatibility

The Pole-Mounted Disconnect Switch is delivered to utility companies and distributors in regions such as Southeast Asia, the Middle East, Africa, Latin America, and South Asia. The specifications, operational mechanism, and certification all correspond with the market of supply.

Breaker Dimensions, Weight & Packing

The measurement and mass of circuit breakers vary according to the voltage variety and installation system. Outdoor breakers are made light for easy mounting, while indoor circuits have pre-installed fixtures for panel mount installation. The measurements and weight specifications are verified through order drawings.

  • Measurement based on model drawings
  • Mechanism is locked and poles are safeguarded for the shipment
  • Installation kit is provided

outdoor pole mounted disconnect switch--40.5KV 250a standards and certifications

Standards & certifications

Obtained in accordance with IEC 62271 and GB 1985, the switch has type test documents for utility and project approvals.

  • Standards expected in design: IEC 62271/GB 1985
  • Outdoor dielectric strength rating at 40.5kV.
  • Mechanical performance tested in repetitive operation.
  • Coating against corrosion for coastal and industrial conditions (optional).
outdoor pole mounted disconnect switch--40.5KV 250a OEM and B2B supply support

OEM & B2B supply support

Subian Electric, an esteemed manufacturer and factory supplier of power equipment, aids utilities, EPC contractors and dealers in making the proper choices when it comes to disconnect switch, samples and quotes.

If you require a different power rating or operating mechanism, please reach out to us with your required voltage, current quantity and destination market for advice.

  • You can easily evaluate our samples.
  • We have the flexibility to meet different quantities of order needs in utility projects.
  • We provide all OEM / ODM services.
  • We take care of marking and packaging.
  • We support you in your technical documentation and certification needs.


Request a Quote


Frequently Asked Questions

What is the 40.5kV disconnect switch used for?

The unit is used to disconnect and isolate high voltage circuits on a pole in order to perform maintenance and switching of lines and equipment while the system is live.

Can it be operated under load?

Basically, no. The disconnect switch works only when the load is absent. Switching under load is done with the help of circuit breaker or with the help of load switches.

What operating mechanisms are available?

The drive can be operated manually with the help of the special insulated rod for operational acts. However, it is possible to discuss additional options for the particular projects during the negotiations.

Do you supply to utilities and contractors?

Yes. Equipment is supplied to electrical utilities, EPC contractors, dealers and OEM consumers with the possibility of ordering all required documentation and samples too.

Subian Electric Power manufacturing facility in Xuzhou
Manufacturing Base

Disconnect Switch Production in Xuzhou

Subian's Xuzhou facility produces high-voltage disconnector and disconnect switches with contact, insulator and operating mechanism assembly stations. Switches are assembled and adjusted at this plant. In-house production and testing of the Pole-Mounted Disconnect Switch follow the same controlled process at this facility. Clear pricing, test records and OEM options direct from the manufacturer. Reliable fault interruption helps prevent damage to transformers, cables and loads.
  • Disconnector assembly, contact adjustment and testing in-house
  • Supply for distributors, utilities and line projects
Factory Facilities

Disconnector Assembly and Adjustment Areas

The images show the disconnector assembly area, contact adjustment stations and customer inspection activities at Subian's Xuzhou manufacturing facility. The Pole-Mounted Disconnect Switch supplied on this page is manufactured, tested and quality-checked at this site. Close/open performance verified. Buyer inspection welcomed.
Subian disconnect switch production workshop
Operation checksClose/open performance verified.
Disconnector assembly area inside the Subian factory
InspectionBuyer inspection welcomed.
International customer inspecting a disconnect switch at the factory
Mechanism fittingTiming and force adjusted.
Manufacturing Process

Contact, Insulator and Mechanism Assembly

Disconnector production follows: contact system assembly, insulator mounting, operating mechanism fitting, phase adjustment and mechanical operation checks. Manufacturing of the Pole-Mounted Disconnect Switch follows the confirmed specification, with checks recorded at each relevant stage. Voltage, current and breaking ratings matched to your application. Designed to interrupt fault current reliably and protect downstream equipment from damage.
  • Contact systems assembled with confirmed contact pressure
  • Insulators mounted and checked for damage
  • Mechanical operation verified on all three phases
Subian switchgear assembly production line
Enquiry
Subian switchgear assembly process
Production
Technician adjusting a disconnect switch contact
AssemblyPoles and mechanisms assembled.

Contact Alignment and Operating Reliability

Contact pressure, alignment and operating torque are checked against the approved values, and switching operation is verified before packing. Ratings, mechanism type and quantity. Quotations are issued against your specification. Yes, wholesale and distributor supply are supported. Yes, OEM branding and packaging are available.
Subian disconnector contact detail
Send ratings and application.Assembly and testing.
Visitors at the Subian power equipment booth
Subian booth at an international electrical exhibition
Subian team meeting a customer at an electrical exhibition
Customer visiting the Subian transformer booth
Subian international exhibition team
Subian sales representative discussing a project with a visitor
Visitors at the Subian power equipment booth
Subian booth at an international electrical exhibition
Customer Meetings

Disconnector Sourcing Discussions

Our export team discusses disconnector ratings, pole configurations and delivery with distributors and utilities at exhibitions. Switching and protection in renewable plants. Overcurrent protection for distribution feeders. Overload and short-circuit protection in distribution circuits.
Contact Our Export Team
Product Documentation

Disconnector Certificates and Test Records

Type-test reports, routine test records and certificates for disconnect switches can be confirmed according to model and destination market. For the Pole-Mounted Disconnect Switch, certificates, type-test reports and routine test records can be confirmed before ordering. Lead time is confirmed with your order and based on the model and quantity. By voltage, current rating, breaking capacity and quantity. We quote against your specification.
Example switchgear conformity certificate
Conformity documents
Example switchgear type test report
Type-test reports
Packed Subian power equipment prepared for delivery
Packing and shipmentDisconnectors are packed with insulators protected and mechanisms locked.
Product Inquiry

Request Product Information and Pricing

Please provide the product type, rated voltage, capacity, quantity, applicable standard, delivery country and required delivery date. We will reply with a quotation or a list of points requiring confirmation.
  • Product selection and technical clarification
  • OEM, ODM and private-label requirements
  • Quantity, packing and delivery planning

Project and Product Requirements

Fields marked with * are required.
Subian Product Inquiry