The LW3-12 SF6 circuit breaker is a 3-pole, 630A outdoor pole-mounted breaker for 12kV distribution lines, using SF6 gas arc extinction with 16kA/20kA breaking capacity. Manufactured by Subian Electric, it serves utilities, distributors and project buyers.

LW3-12 — Outdoor SF6 Circuit Breaker12 kV · 630 A · 16/20 kA
SF6 Arc Extinction
Pole Mounted
16/20 kA

Key Specifications

  • Rated Voltage — 12 kV
  • Rated Current — 630 A
  • Breaking Capacity — 16 kA / 20 kA
  • Insulation Level — 75 kV impulse; 42 kV power-frequency
  • Arc Extinction — SF6 gas, gas-pressure type
  • Mounting — Outdoor pole mounted
  • Standards — IEC 62271 / GB 1984

Product Overview

Pole-Mounted SF6 Circuit Breaker from a Professional Power Equipment Manufacturer

The LW3-12 SF6 circuit breaker is able to provide reliable overcurrent and short-circuit protection in outdoor 12kV distribution lines. The main reason for this reliability is that it employs SF6 gas in the form of an arc-extinguishing medium.

Vacuum/SF6 Circuit Breaker--LW3-12 630A 3-Pole Outdoor Pole-Mounted — Applications & circuit protection applications

Applications & circuit protection

The SF6 breaker of this type which is affixed on a pole is suitable for overhead distribution lines and transformer feeds wherever it is necessary to ensure the stability of the work of the appliance.

  • Overhead distribution: Protection of the line at an interval of twelve kilovolts.
  • Pole-mounted equipment: Small circuit protectors placed on poles.
  • Rural lines: Reliable switching in suburbs.
  • Station feeds: Protection of the outgoing line
Vacuum/SF6 Circuit Breaker--LW3-12 630A 3-Pole Outdoor Pole-Mounted construction and operating reliability

Construction & operating reliability

The gas-pressure arc-extinguishing construct with SF6 medium offers excellent breaking performance and low overvoltages in cases of switching of both capacitive and inductive currents.

  • The arc-extinguishing mechanism has a very short arc extinction time.
  • It breaks the load current, the overload current and the short-circuit current.
  • It also features low re-ignition and re-combustion parameters when switching.
  • It executes outdoor pole-mounting construction.
  • The long life of mechanical cycle is guaranteed for repeated performance of operations.

Technical Parameter

Parameter Value
Rated voltage 12 kV
Rated frequency 50 Hz
Rated current 630 A
Rated short-circuit breaking current 16 / 20 kA
Power-frequency withstand (1 min) 42 kV
Lightning impulse withstand 75 kV
Rated operating sequence O–180s–CO–180s–CO (Type I)
Mounting Outdoor pole mounted
Standard IEC 62271 / GB 1984

Breaker Cost & Quotation

Please send us your inquiry for a quote on the SF6 Circuit Breakers specifying the required ratings, current values, maximum breaking power levels and the required quantity. The distributor price plus quantity discounts apply for a purchase order placed with you.

  • Quick quoting for standard ratings
  • No-cost OEM branding options are available
  • Export packing is included

Breaker Wiring & Control Connection

Power connections are established between the circuit breaker and the circuit, while the control connections receive close/open signals and auxiliary contacts. The wiring diagrams and connection labels come with the SF6 Circuit Breaker.

  • Terminals for power are marked according to the drawing;
  • Control circuit is prepared and tested;
  • Indication contacts are also available.

Compare Breaker Options

Select the right breaker for your duty:

Feature This Breaker Alternative
Voltage As specified Other classes available
Breaking Per model Higher breaking on request
Mechanism Spring / magnetic per model Manual or motor operation
Mounting Indoor / outdoor per model Pole or panel mounting

Export Markets & Country Compatibility

The SF6 Circuit Breaker is sold by power producers and vendors in Asia Pacific, Middle East, Africa, and Latin America. Various parameters are set according to the market in question.

Breaker Dimensions, Weight & Packing

The weight and dimensions of a breaker are based on the voltage class of the breaker and the type of operation. Breakers for outdoor use but mounted on poles are made small and less heavy to enable easy installation, while breakers for indoor use are delivered as fully made-up for installation into the panel. The weight and the dimensions are confirmed in order drawings.

  • Dimensions from the model drawing
  • The mechanism is locked and the poles are protected for delivery
  • The mounting accessories are supplied

Vacuum/SF6 Circuit Breaker--LW3-12 630A 3-Pole Outdoor Pole-Mounted standards and certifications

Standards & certifications

Built according to IEC standards 62271 and GB 1984, the LW3-12 comes with type approval certificates.

  • Complies to IEC 62271 / GB 1984.
  • Uses SF6 as an arc-extinguishing medium.
  • Suitable for outdoor use.
  • Boasts a 16/20 kA breaking capacity.
Vacuum/SF6 Circuit Breaker--LW3-12 630A 3-Pole Outdoor Pole-Mounted OEM and B2B supply support

OEM & B2B supply support

Being an accomplished maker, and supplier of power equipment, Subian Electric has established itself as a premier supplier of SF6 circuit breakers to utilities, EPC contractors, and other distributors offering samples and technical support.

Please get in touch with us regarding other options or designs you may want and the quantity you need.

  • We have samples ready for tests.
  • We offer flexible quantities.
  • We offer OEM and ODM solutions.
  • We provide custom marking and packing of your order.
  • Our technical documents and certificates have got your back.


Request a Quote


Frequently Asked Questions

What is the LW3-12 used for?

It shields 12 kV outdoor distribution lines from excess loads and short circuits. It is intended to be installed on poles or structures of the network.

Why SF6 arc extinction?

 The function of the SF6 is the rapid and clean extinguishing of the arc due to its strong breaking ability and low overvoltage generated during the switching operation.

What is the breaking capacity?

Breaking capacity is a nominal short circuit breaking current of either 16kA or 20 kA for the respective models at 12 kV, 630 A.

Is it suitable for remote areas?

The LW3-12 is an ideal explanation for the rural zones due to its compact dimensions and reliable performance.

Subian Electric Power manufacturing facility in Xuzhou
Manufacturing Base

SF6 Circuit Breaker Production in Xuzhou

Subian's Xuzhou facility produces SF6 circuit breakers with tank assembly, gas filling and mechanical test stations. SF6 breakers are assembled, filled and tested at this site. In-house production and testing of the SF6 Circuit Breaker follow the same controlled process at this facility. Reliable fault interruption helps prevent damage to transformers, cables and loads. Voltage, current and breaking ratings matched to your application.
  • SF6 breaker assembly, gas filling and testing at our plant
  • Supply for distributors, utilities and pole-mounted projects
Factory Facilities

SF6 Breaker Assembly and Gas Areas

The images show the SF6 breaker assembly area, gas filling station and customer inspection activities at Subian's Xuzhou manufacturing facility. The SF6 Circuit Breaker supplied on this page is manufactured, tested and quality-checked at this site. Buyer inspection welcomed. Poles and mechanisms assembled.
Subian SF6 circuit breaker production workshop
InspectionBuyer inspection welcomed.
SF6 breaker assembly area inside the Subian factory
TestingMechanical operation verified.
International customer inspecting an SF6 circuit breaker at the factory
Mechanism fittingTiming and force adjusted.
Manufacturing Process

Assembly, Gas Filling and Operation Checks

SF6 circuit breaker production follows: interrupter and tank assembly, mechanism fitting, evacuation and gas filling, leak checking and mechanical operation tests. Manufacturing of the SF6 Circuit Breaker follows the confirmed specification, with checks recorded at each relevant stage. Compact, modular construction simplifies panel or pole mounting and connection. Designed to interrupt fault current reliably and protect downstream equipment from damage.
  • Interrupters and tanks assembled to drawing
  • Mechanisms fitted and adjusted for correct operation
  • Leak and operation tests recorded
Subian switchgear assembly production line
Build
Subian switchgear assembly process
Production
Technician adjusting a circuit breaker mechanism
Pole assemblyInterrupters assembled into poles.

Gas Tightness and Operating Performance

Gas tightness is verified, and the mechanism is operated repeatedly to confirm stable close/open performance before routine testing. Yes, operating mechanism options can be arranged per application. By voltage, current rating, breaking capacity and quantity. We quote against your specification. Lead time is confirmed with your order and based on the model and quantity.
Subian SF6 breaker tank detail
Production and testing.Assembly and testing.
Visitors at the Subian power equipment booth
Subian booth at an international electrical exhibition
Subian team meeting a customer at an electrical exhibition
Customer visiting the Subian transformer booth
Subian international exhibition team
Subian sales representative discussing a project with a visitor
Visitors at the Subian power equipment booth
Subian booth at an international electrical exhibition
Customer Meetings

SF6 Breaker Sourcing Discussions

Our team discusses SF6 breaker ratings, pole configurations and delivery with distributors and utilities at electrical exhibitions. Switching and protection in renewable plants. Protection for motors, transformers and feeders. Overcurrent protection for distribution feeders.
Contact Our Export Team
Product Documentation

SF6 Breaker Certificates and Test Records

Type-test reports, routine test records and certificates for SF6 circuit breakers can be confirmed according to model and destination market. For the SF6 Circuit Breaker, certificates, type-test reports and routine test records can be confirmed before ordering. Ratings, mechanism type and quantity. Quotations are issued against your specification. Yes, OEM branding and packaging are available.
Example switchgear conformity certificate
Conformity documents
Example switchgear type test report
Type-test reports
Packed Subian power equipment prepared for delivery
Packing and shipmentSF6 breakers are packed with gas pressure preserved and mechanisms protected.
Product Inquiry

Request Product Information and Pricing

Please provide the product type, rated voltage, capacity, quantity, applicable standard, delivery country and required delivery date. We will reply with a quotation or a list of points requiring confirmation.
  • Product selection and technical clarification
  • OEM, ODM and private-label requirements
  • Quantity, packing and delivery planning

Project and Product Requirements

Fields marked with * are required.
Subian Product Inquiry