This three-phase pole-type distribution transformer (TRANSFORMADOR TRIFASICO TIPO POSTE) delivers efficient low-loss distribution for 11–33kV networks, rated 50kVA–2500kVA. Manufactured by Subian Electric, it serves Latin American and global distribution projects. As a professional manufacturer and factory supplier, Subian Electric welcomes enquiries from distributors, wholesalers and project buyers.

Three-Phase — Pole-Type Distribution Transformer11–33 kV · 50–2500 kVA
High Efficiency
Pole Mounted
11–33 kV

Key Specifications

  • Primary Voltage — 11 – 33 kV
  • Secondary Voltage — 0.4 – 10 kV
  • Power Rating — 50 – 2500 kVA
  • Efficiency — ≥98% at rated load
  • Cooling — ONAN / ONAF
  • Insulation — Mineral oil / dry-type option
  • Standards — IEC 60076 / NEMA / DOE

Product Overview

Three-Phase Pole-Type Distribution Transformer from Subian Electric’s Xuzhou Factory

This particular three-phase pole-type distribution transformer is built for the effective and low-loss transmission of power used in overhead installations. It lowers the primary voltage of 11-33 kV to be used by consumers in the agriculture, commercial and residential sector. The device boasts a better than 98 percent efficiency rating and offers either oil-type or dry-type insulation along with a sturdy pole-mounted design.

Power Distribution Transformer--TRANSFORMADOR TRIFASICO TIPO POSTE — Applications & circuit protection applications

Applications & circuit protection

The pole-type transformer works well in airborne distribution systems in which compact, dependable reduction of voltage is needed.

  • Overhead systems: Three-phase distributions via poles.
  • Residential applications: supply by community and neighborhood lines.
  • Agricultural applications: pumping and farm supply.
  • Industrial applications: small industrial loads and commercial loads.
Power Distribution Transformer--TRANSFORMADOR TRIFASICO TIPO POSTE construction and operating reliability

Construction & operating reliability

Low-loss cores, professional winding and reliable cooling assure high performance and dependable service in outdoor pole-mounted applications.

  • Efficiency >98% under rated loads
  • Pole mounting for overhead network
  • Dielectric oil or dry type insulation
  • Rugged construction for outdoor operation
  • Conforms to IEC / NEMA / DOE efficiency requirements.

Technical Parameter

Parameter Value
Rated capacity range 30-2500 kVA
Voltage combination (HV) 6 / 6.3 / 10 / 10.5 / 11 kV
Tap range ±5% / ±2×2.5%
Voltage (LV) 0.4 / 0.69 kV
Connection group Yyn0 / Dyn11 / Yzn11
No-load loss (typical range) 100-2400 W
Load loss (typical range) 630-24000 W
No-load current (typical range) 0.5-2.3%
Short-circuit impedance 4%
Primary voltage 11 – 33 kV
Secondary voltage 0.4 – 10 kV
Power rating 50 – 2500 kVA
Frequency 50/60 Hz
Efficiency ≥98% at rated load
Insulation Mineral oil (dry-type option)
Cooling ONAN / ONAF (oil); AN/AF (dry)
Standard IEC 60076 / NEMA / DOE

Transformer Price & Factory Quotation

As a direct manufacturer, we price transformers based on the rated capacity, voltage combinations, materials used for the core and winding, extras included with the units as well as order quantities. Orders of containers as well as orders of distributors are placed at volume prices. Because the cost of materials fluctuates with the market, we issue written pricing offering current rates. Therefore, you will have to send a request for a quotation of Pole-Type Distribution Transformers indicating your required rated capacity and order quantity.

  • Indeed, OEM / ODM promotes the brand without any effect on the base transformer price.
  • Costs associated with spare cores, spare units as well as special packaging are estimated separately.
  • The following terms are applicable for export orders: FOB / CIF / DDP.

How to Connect This Transformer

Verify prior to energizing the Pole-Type Distribution Transformer that both tap position is compatible with supply voltage and the connecting group corresponds to system connection. Connect HV bushings to the side of supply and LV terminals to that of the load. Ensure appropriate connection of earthing terminals.

  • Note tap position and checking supply voltage.
  • Use HV and LV terminals for power connections.
  • Connect earthing terminals per standards.

This Transformer vs. Alternative Ratings

Compare typical configurations to select the correct rating:

Item This Product Smaller / Larger Option
Capacity As specified on this page Lower or higher kVA available
Voltage As specified Other primary voltages available
Impedance Per standard / custom Adjusted to network requirements
Cooling ONAN or AN/AF per type Forced cooling option on request
Application Distribution / power Industrial, renewable or utility

Export Markets & Country Compatibility

Throughout Asia, Africa, the Middle East, Latin America, and Europe, we provide Pole Type Distribution Transformer to distributors, utilities, and project customers. For each destination, we check the required voltage, frequency, connection group, and certification needs before starting production.

Transformer Dimensions, Weight & Packing

The dimensions and weights of transformers depend on the load rating, the voltage of the device, and the type of transformer. It is expected that units with a power rating of 100 kVA design will be 1000-1200 mm long, from 500 to 700 mm deep, and 1100-1400 mm tall and have a weight of approximately 600-900 kg. The dimension drawings will be provided for confirmation and will be checked at the time of order placement.

  • The unit dimension drawing will be provided before the manufacturing process starts
  • Packing will be carried out in accordance with the export standards and marking before lifting
  • Please specify the way of transportation and port for delivery arrangement

Power Distribution Transformer--TRANSFORMADOR TRIFASICO TIPO POSTE standards and certifications

Standards & certifications

This transformer has been produced as per the standards mentioned in IEC 60076 and has also been tested in accordance with the guidelines laid out by NEMA/DOE.

  • Standards for design: IEC 60076.
  • Efficiency checked as per the practices of NEMA/DOE.
  • Availability of type test and routine test report.
  • Documentation available for approval and certification.
Power Distribution Transformer--TRANSFORMADOR TRIFASICO TIPO POSTE OEM and B2B supply support

OEM & B2B supply support

Subian Electric, as a leading manufacturer of electrical equipment, provides pole transformer support to power-producing companies, contractors and electrical equipment suppliers worldwide.

The manufacturing company can be contacted for specific requirements related to voltage levels, performance and capacity.

  • Standard models of the pole transformers can be produced.
  • Custom production quantities available for the manufacturing.
  • OEM and ODM service for specific production needs.
  • Customized packaging services.
  • Certification and qualification procedures.


Request a Quote


Frequently Asked Questions

What is a three-phase pole-type transformer?

It is a three-phase transformer for electric power that is mounted on a wooden, concrete or metal pole for power distribution purposes.

What ratings are available?

It can operate with a capacity in the range of 50 kVA to 2500 kVA with a primary voltage of 11kV to 33kV.

Is it suitable for Latin American networks?

Definitely, the device can be made in designed configurations for the usual electrical connections in Latin America.

Do you provide test reports?

Yes, we provide type test and routine test reports for the successful approval of the project and marketing the product.

Subian Electric Power manufacturing facility in Xuzhou
Manufacturing Base

Oil-Immersed Transformer Production in Xuzhou

Subian operates a 30,000-square-metre facility in Xuzhou, Jiangsu, dedicated to power and distribution equipment. For oil-immersed transformers, our plant covers coil winding, core stacking, tank fabrication, vacuum drying and oil-filling lines, so every unit is produced and tested in-house before delivery. In-house production and testing of the Pole-Type Distribution Transformer follow the same controlled process at this facility. Deal directly with the manufacturer for clear pricing, production updates and delivery planning, with OEM and distributor programs available. A single export team handles quotation, technical questions, production progress and shipping documents.
  • Complete oil-immersed transformer production chain, from coil to tank
  • Technical communication for distributors, EPC contractors and project owners
Factory Facilities

Winding, Tank and Oil Treatment Areas

The images below show the coil winding line, tank welding and assembly stations, and customer inspection activities for oil-immersed transformers at our Xuzhou plant. The Pole-Type Distribution Transformer supplied on this page is manufactured, tested and quality-checked at this site. Moisture removed before oil filling to protect insulation life. Ratio, losses and insulation verified on the test bench.
Subian oil-immersed transformer winding workshop
Quality centerRoutine tests recorded and reviewed before dispatch.
Transformer tank assembly line inside the Subian factory
Material preparationSteel, copper and insulation inspected to the approved bill of materials.
International customer inspecting an oil-immersed transformer at the factory
Final testingRatio, losses and insulation verified on the test bench.
Manufacturing Process

From Core Stacking to Vacuum Oil Filling

Oil-immersed transformer production follows a controlled sequence: core cutting and stacking, coil winding and drying, core-coil assembly, tanking, vacuum oil filling and final routine testing. Manufacturing of the Pole-Type Distribution Transformer follows the confirmed specification, with checks recorded at each relevant stage. Quality insulation, verified windings and proper oil treatment are designed to reduce unplanned outages at your site. A distribution transformer sits in the middle of your network — sound insulation design and quality materials keep it running through load var
  • Core laminations cut and stacked to the approved design
  • Coils dried in a vacuum oven before tanking
  • Vacuum oil filling and sealed final assembly
Transformer coil winding production line
Packing & Shipment
Transformer core and coil assembly process
Confirm Quotation
Technician carrying out transformer winding work
Customer visitsBuyers can inspect units and review records at the plant.

Insulation, Drying and Oil Treatment

Insulation paper and pressboard are applied to confirmed drawings, windings are vacuum-dried, and treated insulating oil is filled under vacuum to keep moisture and gas within specification. Yes. OEM and ODM supply includes custom nameplates, packaging and documentation for distributors and brands. Packing and shipping are planned around unit size and transport method, with terms agreed per order. Yes. We configure voltage combinations and tap ranges to your requirement and confirm draw
Transformer core manufacturing detail
Export packing and loading are confirmed with you, with documents issued on dispatch.Receive pricing, lead time and drawings for your approval.
Visitors at the Subian power equipment booth
Subian booth at an international electrical exhibition
Subian team meeting a customer at an electrical exhibition
Customer visiting the Subian transformer booth
Subian international exhibition team
Subian sales representative discussing a project with a visitor
Visitors at the Subian power equipment booth
Subian booth at an international electrical exhibition
Customer Meetings

Transformer Selection Talks at Exhibitions

Our export and engineering teams meet distributors, contractors and project buyers at electrical industry exhibitions to discuss voltage levels, capacity, tap range, standards and delivery schedules for oil-immersed transformers. Supplying factories, mines and processing plants that need dependable power for continuous production. Electrification and renewable connection projects with project-level supply. Step-down and step-up duties in medium-voltage distribution systems.
Contact Our Export Team
Product Documentation

Transformer Certificates, Test Reports and Shipping Records

For each oil-immersed transformer order we confirm the applicable type-test report, routine test record, certificate and packing list with the buyer before shipment. For the Pole-Type Distribution Transformer, certificates, type-test reports and routine test records can be confirmed before ordering. Yes — voltage, tap range, connection group, impedance and accessories can be adjusted and confirmed on drawings. Yes. Distributor and wholesale programs include account management, technical material and priority production.
Example transformer conformity certificate
Conformity certificates
Example English transformer type test report
Type-test reports
Packed Subian power equipment prepared for delivery
Packing and shipmentTransformers are packed with confirmed lifting points, oil-level checks and transport method for safe delivery.
Product Inquiry

Request Product Information and Pricing

Please provide the product type, rated voltage, capacity, quantity, applicable standard, delivery country and required delivery date. We will reply with a quotation or a list of points requiring confirmation.
  • Product selection and technical clarification
  • OEM, ODM and private-label requirements
  • Quantity, packing and delivery planning

Project and Product Requirements

Fields marked with * are required.
Subian Product Inquiry