Request a Quote
Home / Product / 10kV Dry-Type Transformer-SCBH series Amorphous Alloy
Products

10kV Dry-Type Transformer-SCBH series Amorphous Alloy

Amorphous Alloy Transformer — OEM/ODM & Wholesale Supplier

The SCBH15/17/19 amorphous alloy dry-type transformer delivers ultra-low no-load losses for 10kV distribution, rated 100kVA–2500kVA. Manufactured by Subian Electric, it serves urban grids, renewable projects and energy-conscious facilities. Backed by an experienced factory and export sales team, it is a dependable choice for distributors, wholesalers and project procurement.

SCBH — Amorphous Alloy Dry-Type Transformer10 kV · 100–2500 kVA · SCBH15/17/19
Ultra-Low Loss
Amorphous Core
SCBH15/17/19

Key Specifications

  • Model — SCBH15 / SCBH17 / SCBH19
  • Voltage Rating — 6 / 10 kV (primary), 0.4 kV (secondary)
  • Power Rating — 100 – 2500 kVA
  • Core — Amorphous alloy
  • Insulation Class — F / H
  • Cooling — AN / AF
  • Standards — IEC 60076 / GB 10228

Product Overview

Ultra-Low-Loss Amorphous Alloy Transformer from a Leading Chinese Manufacturer

The 10kV SCBH series amorphous alloy dry-type transformer is made of a high-quality amorphous alloy iron core, enabling the reduction of no-load and load losses considerably, thereby allowing savings in energy and operating costs. The transformer is indicated for operation in different harsh environments and is an advanced and eco-friendly solution for urban grids, renewable energy and energy-efficient customers.

10kV Dry-Type Transformer-SCBH series Amorphous Alloy — Applications & circuit protection applications

Applications & circuit protection

This transformer is right for applications where eco-friendliness and efficiency are important in the area of power distribution.

  • Urban distribution: High-performance indoor MV network.
  • Sustainable energy: Distribution of solar and wind plants.
  • Industrial parks: Efficient electric energy supply.
  • Transport sector: Dependable indoor distribution.
10kV Dry-Type Transformer-SCBH series Amorphous Alloy construction and operating reliability

Construction & operating reliability

Amorphous alloy cores lower no-load losses remarkably well and provide a high level of reliability at the same time due to cast resin cover and AN/AF cooling systems.

  • Amorphous alloy core for delivering ultra-low no-load losses.
  • The models SCBH15/17/19 are available.
  • Fire-safe, oil-free type of the construction.
  • High efficiency and savings in the energy consumed.
  • High suitability for severe conditions of exploitation.

Technical Parameter

Parameter Value
Rated capacity range 30-2500 kVA
Voltage combination (HV) 6 / 6.3 / 10 / 10.5 / 11 kV
Tap range ±5% / ±2×2.5%
Voltage (LV) 0.4 kV
Connection group Yyn0 / Dyn11
No-load loss (typical range) 70-1800 W
Load loss (typical range) 710-22500 W
No-load current (typical range) 0.5-1.6%
Short-circuit impedance 4-6%
Model SCBH15 / SCBH17 / SCBH19
Voltage rating 6 / 10 kV (primary), 0.4 kV (secondary)
Power rating 100 – 2500 kVA
Rated frequency 50/60 Hz
Insulation class F / H
Cooling AN / AF
Protection IP20 / IP23 / IP54 (customizable)
Standard IEC 60076 / GB 10228

Transformer Price Guide & Factory Pricing

Purchasing straight from the manufacturer eliminates any intermediary profit margins. The cost of the Amorphous Alloy Transformer is based on the rated power and materials used — copper or aluminium coils, silicon steel or amorphous core and the size of the order. Let us know your power rating, voltage and amount required as well as the delivery port and we will get back to you with an offer.

  • Clear factory pricing with no hidden costs
  • Volume discounts available for cargo containers and project orders
  • Free technical assistance on selection with every quotation

Transformer Wiring & Connection

The Amorphous Alloy Transformer comes with clearly labeled high voltage and low voltage terminals. The connection group designation, Yyn0/Dyn11, tells users how they should connect it to their system. The primary connections include standard cable lugs and connections with busbars for high voltage terminals, while primary terminals allow users to easily connect cables to the transformer. This particular transformer comes with connection diagrams for clear understanding.

  • Marking of terminal according to IEC/GB convention
  • Connection groups include available Dyn11 and Yyn0
  • Each unit comes with connection diagram

Compare with Other Transformer Options

Choose the right unit for your project:

Feature This Series Alternative Option
Insulation Oil-immersed / cast-resin as specified Dry-type or amorphous alloy options
Capacity Per specification (30-2500 kVA typical) Higher ratings available on request
Mounting Pole / pad / substation per model Indoor or outdoor per enclosure
Loss level Standard or low-loss series Amorphous ultra-low loss option
Best for Distribution and power projects Energy-saving or space-limited sites

Export Markets & Country Compatibility

The Amorphous Alloy Transformer can be seen in markets like Southeast Asia, the Middle East, Africa, Latin America, South Asia, and Europe. Units functioning at 50 Hz meet demand of most international grids, and versions at 60 Hz are provided to markets like North America and parts of the Middle East. Voltage combinations are adjusted to suitable supply voltages in respective countries.

Transformer Dimensions, Weight & Packing

voltage, and type of the unit. The approximate standard sizes for distribution kVA units are: for 100 kVA oil cooled units size approximately between 1000 mm and 1200 mm in length, 500 mm and 700 mm in width, and about 1100 mm and 1400 mm in height with shipping weight of around 600 kg to 900 kg depending on kind of rated power; this trend continues for higher power ratings.

  • The sizes drawings are sent for confirmation to the client before production
  • Packaging according to the standards with lifting points
  • Make sure that you specify the method of transport and port for delivery purposes

10kV Dry-Type Transformer-SCBH series Amorphous Alloy standards and certifications

Standards & certifications

According to IEC 60076 and GB 10228, this transformer will be provided along with type-test reports for project validation.

  • Standard used for design: IEC 60076 / GB 10228.
  • Core loss performance of amorphous material confirmed.
  • Type-test and routine-test reports can be issued.
  • Documentation for certification and apporvals.
10kV Dry-Type Transformer-SCBH series Amorphous Alloy OEM and B2B supply support

OEM & B2B supply support

Being a specialized power equipment producer, Subian Electric provides support to energy efficient projects, contractors and distributors with amorphous alloy transformers for the respective projects.

To know about the specific capacity or load levels, clients can contact us with their requirement.

  • We can provide samples and drawings.
  • Depth in flexibility in terms of quantity and project purchase.
  • OEM and ODM support for every type of customer.
  • Possibility for different marking and packaging techniques.
  • Possibility for technical documentation.


Request a Quote


Frequently Asked Questions

What is an amorphous alloy transformer?

It uses an amorphous alloy core instead of conventional silicon steel thus resulting in very low no-load losses with higher efficiency.

What models are available?

Models SCBH15, SCBH17 and SCBH19 are available at 10kV rating with capacity from 100kVA to 2500kVA.

Why is it energy efficient?

Use of the amorphous core drastically reduces no-load losses and hence energy consumption.

Do you provide test reports?

Yes, we provide type-test and routine test reports.

Subian Electric Power manufacturing facility in Xuzhou
Manufacturing Base

Amorphous Alloy Transformer Production in Xuzhou

Subian's Xuzhou facility operates an amorphous alloy transformer line with specialised core cutting and annealing equipment, coil winding stations and a complete routine test area. Low-loss amorphous transformers are manufactured and tested in-house. In-house production and testing of the Amorphous Alloy Transformer follow the same controlled process at this facility. Routine test records, production photos and certificates give you proof of quality before and after shipment. Order straight from the manufacturer — the price you discuss is the factory price, with volume terms for larger orders.
  • Amorphous core cutting, assembly and low-loss transformer production
  • Supply support for distributors, utilities and energy-efficiency projects
Factory Facilities

Amorphous Core and Assembly Areas

The following images show the amorphous core workshop, transformer assembly stations and customer inspection activities at Subian's Xuzhou manufacturing facility. The Amorphous Alloy Transformer supplied on this page is manufactured, tested and quality-checked at this site. Buyers can inspect units and review records at the plant. Ratio, losses and insulation verified on the test bench.
Subian amorphous alloy transformer workshop
AssemblyCore-coil assembly and tanking on dedicated stations.
Amorphous core assembly line inside the Subian factory
Vacuum dryingMoisture removed before oil filling to protect insulation life.
International customer inspecting an amorphous transformer at the factory
Coil windingHV/LV coils wound on controlled machines with insulation per drawing.
Manufacturing Process

Low-Loss Core and Coil Manufacturing

Amorphous transformer manufacturing emphasises careful core handling: ribbon cutting, core assembly, coil winding, drying, core-coil assembly, tanking and routine testing with no-load loss verification. Manufacturing of the Amorphous Alloy Transformer follows the confirmed specification, with checks recorded at each relevant stage. Voltage combination, tap range, connection group and loss level can be matched to your network and load, not just a fixed catalogue. Losses run constantly — a low-loss unit appears on every month's power bill for the lifetime of the transformer.
  • Amorphous ribbon cores handled to avoid stress and edge damage
  • Coils wound and dried before core-coil assembly
  • No-load loss measured on every finished unit
Transformer coil winding production line
Send Your Specification
Transformer core and coil assembly process
Confirm Quotation
Technician carrying out transformer winding work
Material preparationSteel, copper and insulation inspected to the approved bill of materials.

Loss Control and Core Handling

Because amorphous core loss is sensitive to mechanical stress, cutting and assembly follow strict handling procedures. Finished units are tested for no-load loss, load loss and impedance against the approved values. Yes — voltage, tap range, connection group, impedance and accessories can be adjusted and confirmed on drawings. Standard routine tests include winding resistance, ratio and vector group, no-load and load loss, impedance, insulation and oil tests. Specification and quantity. We quote against your re
Transformer core manufacturing detail
Capacity, voltage, quantity and destination port. Even a simple enquiry is fine — we will help fill in the details.Receive pricing, lead time and drawings for your approval.
Visitors at the Subian power equipment booth
Subian booth at an international electrical exhibition
Subian team meeting a customer at an electrical exhibition
Customer visiting the Subian transformer booth
Subian international exhibition team
Subian sales representative discussing a project with a visitor
Visitors at the Subian power equipment booth
Subian booth at an international electrical exhibition
Customer Meetings

Energy-Saving Transformer Discussions

Our export team meets distributors and project buyers to discuss amorphous alloy transformer ratings, no-load loss levels, standards and delivery for energy-saving distribution projects. Extending and upgrading distribution in utility programs where units stay in service for decades. Step-down and step-up duties in medium-voltage distribution systems. Feeding distribution networks where steady voltage regulation and low losses directly affect
Contact Our Export Team
Product Documentation

Amorphous Transformer Test Records

Routine test records, type-test reports and certificates for amorphous alloy transformers are available according to model and destination market requirements. For the Amorphous Alloy Transformer, certificates, type-test reports and routine test records can be confirmed before ordering. By capacity, voltage, loss level, materials and quantity. We send a written quotation against your exact specification, with volume pricing for larger orders. Packing and shipping are planned around unit size and transport method, with terms agreed per order.
Example transformer conformity certificate
Routine test records
Example English transformer type test report
Type-test reports
Packed Subian power equipment prepared for delivery
Packing and shipmentAmorphous transformers are packed to protect cores and windings during transport, with loading confirmed.
Product Inquiry

Request Product Information and Pricing

Please provide the product type, rated voltage, capacity, quantity, applicable standard, delivery country and required delivery date. We will reply with a quotation or a list of points requiring confirmation.
  • Product selection and technical clarification
  • OEM, ODM and private-label requirements
  • Quantity, packing and delivery planning

Project and Product Requirements

Fields marked with * are required.
Subian Product Inquiry