Request a Quote
Home / Product / Current Transformer –10KV Indoor High Voltage
Products

Current Transformer –10KV Indoor High Voltage

Cast Resin Current Transformer — OEM/ODM & Wholesale Supplier

This 10kV indoor current transformer uses epoxy resin casting insulation for excellent dielectric and mechanical strength in MV distribution systems. Available in multiple ratios with 5A/1A secondary output, it is manufactured by Subian Electric for switchgear OEMs, utilities and export distributors.

10kV Indoor CT — Epoxy Resin Cast10 kV · 100–1000 A · Class 0.5 / 5P
Epoxy Cast Insulation
Indoor 10 kV
Multi-Ratio

Key Specifications

  • Rated Voltage — 10 kV
  • Primary Current — 100 / 200 / 400 / 630 / 1000 A
  • Secondary Current — 5 A or 1 A
  • Accuracy Class — 0.5 / 1.0; 5P / 10P
  • Insulation — Epoxy resin casting, indoor
  • Standards — IEC 60044-1 / IEC 61869
  • OEM / ODM — Ratios and terminal options available

Product Overview

Indoor 10kV Cast Resin Current Transformer from a Leading Chinese Manufacturer

Equipped with epoxy resin casting insulation, the 10kV indoor high-voltage current transformer converts high primary currents into low secondary signals that can be safely measured in MV distribution and switchgear systems. With a cast resin body, it offers high degree of insulation, as well as overcoming adverse environment and mechanical influences.

Current Transformer --10KV Indoor High Voltage — Applications & circuit protection applications

Applications & circuit protection

The indoor CT is appropriate for applications involving 10kV switchgear, distribution panels, and substation secondary circuits where there is a need for exact current conversion and dependable insulation.

  • MV switchgear: Current measurement for protection and measurement purposes.
  • Distribution panels: Feeder and transformer current sensing function.
  • Substation applications: Secondary circuits used for relays and instruments.
  • OEM equipment: CT for switchgear and packaged assemblies.
Current Transformer --10KV Indoor High Voltage construction and operating reliability

Construction & operating reliability

Casting of epoxy resin ensures that the windings are embedded within the epoxy resin, making it possible for the CT to deliver excellent dielectric properties, dimensional stability, and durability against humidity and dirt conditions that occur in normal indoor environments.

  • A wide range of primary current rating of from 100A to 1000A.
  • A secondary output of either 5A or 1A or even classes of 0.5/1.0 or 5P/10P.
  • High quality connections for easy secondary wiring.
  • Compact design ideal for a standard switchgear apparatus.

Technical Parameter

Parameter Value
Rated voltage 10 kV
Rated primary current 100 / 200 / 400 / 630 / 1000 A
Rated secondary current 5 A or 1 A
Accuracy class 0.5, 1.0 (metering); 5P, 10P (protection)
Insulation Epoxy resin casting, indoor
Rated frequency 50/60 Hz
Application MV switchgear metering and protection

Instrument Transformer Cost & Quote

Please provide the ratio, accuracy rating, and number of pieces you require for us to generate a quote for Cast Resin Current Transformer. Discounts are available for switchgear and panel manufacturers.

  • Quotation based on technical specifications
  • OEM and private label services available
  • Quick delivery of conventional models

CT Wiring & Secondary Connection

The Cast Resin Current Transformer has properly identified primary and secondary terminals. Make sure that the secondary circuit is connected to the a meter or relay in the correct way and the secondary circuit must never be left open when the transformer is energized.

  • P1/P2 and S1/S2 indications for correct wiring conventions
  • Polarity conventions to ensure proper connections
  • Secondary short-circuiting options are available on request

Compare CT Options

Choose the instrument transformer that fits your scheme:

Feature This CT Alternative
Ratio As specified Other ratios available
Accuracy Per class 0.2 / 0.5 / protection class
Insulation Epoxy cast / oil Indoor or outdoor design
Application Metering / protection Multi-ratio or special duty

Export Markets & Country Compatibility

Instrument transformers are sent to manufacturers and dealers of switchgear, which are specified to the standards, accuracies and ratios applicable in each particular country.

CT Dimensions, Weight & Packing

The size and weight of the device depend on the type of insulation, and installation process. The units are designed for either saw panel or cable mounted installation, while terminals are safe during shipping, thus providing the expected performance. The drawings with dimensions are provided in the technical information.

  • Compact design for panel mounting devices
  • Terminals secure during transit
  • Dimensions diagram supplied based on the model

Current Transformer --10KV Indoor High Voltage standards and certifications

Standards & certifications

Developed in accordance with IEC 60044-1 / IEC 61869, this CT is offered with type-test and routine-test certification for project approval.

  • Manufacturing standard: IEC 60044-1 / IEC 61869 series.
  • Indoor insulation class 10 kV.
  • Tested accuracy for metering and protection classes.
  • Signature and designation of terminals according to the standard.
Current Transformer --10KV Indoor High Voltage OEM and B2B supply support

OEM & B2B supply support

Subian Electric, as a power equipment manufacturer and factory supplier, partners with switchgear manufacturers, distributors, and utilities to provide CT supply, sampling, and technical support.

Provide us with your specifications and quantity to confirm the right configuration, design custom ratios, burdens or secondaries.

  • Samples available for testing.
  • Choosing the right quantity depending on your project and needs.
  • OEM / ODMhelping you with technical documents and certifications.


Request a Quote


Frequently Asked Questions

What are the available ratios?

Common primary currents include 100A, 200A, 400A, 630A, and 1000A, with a secondary output of either 5A or 1A. Other ratios can be customized according to customer requirements.

What accuracy classes are offered?

Measurement and metering applications are typically done in classes 0.5 and 1.0. In the case of protection relay applications, classes 5P and 10P are used.

Why is epoxy resin casting used?

Epoxy casting provides strong insulation, good creepage performance, and high mechanical reliability, which are suitable for demanding conditions of indoor MV environments.

Can I order custom specifications?

Yes. Custom ratios, burdens and terminal arrangements can be offered in OEM projects. Get in touch with us describing the details of your requirements.

Subian Electric Power manufacturing facility in Xuzhou
Manufacturing Base

Epoxy-Cast Instrument Transformer Production in Xuzhou

Subian's Xuzhou facility produces epoxy resin cast instrument transformers with vacuum casting, curing and test stations. Cast CTs and PTs are manufactured and tested at this site. In-house production and testing of the Cast Resin Current Transformer follow the same controlled process at this facility. Test results accompany every unit. Stable accuracy supports correct metering and protection coordination.
  • Epoxy casting, curing and testing for instrument transformers in-house
  • Supply for distributors, panel builders and utilities
Factory Facilities

Casting, Curing and Test Areas

The images show the epoxy casting area, curing ovens and customer inspection activities for instrument transformers at Subian's Xuzhou manufacturing facility. The Cast Resin Current Transformer supplied on this page is manufactured, tested and quality-checked at this site. Buyer inspection welcomed. Insulation applied per drawing.
Subian epoxy-cast instrument transformer production workshop
AssemblyTerminals and housings fitted.
Epoxy casting area inside the Subian factory
Core preparationCores prepared for winding.
International customer inspecting a cast instrument transformer at the factory
WindingCores and coils wound to the approved turns.
Manufacturing Process

Winding, Casting and Accuracy Testing

Epoxy-cast instrument transformer production follows: core and coil preparation, vacuum resin casting, oven curing, terminal fitting and ratio/accuracy testing. Manufacturing of the Cast Resin Current Transformer follows the confirmed specification, with checks recorded at each relevant stage. Stable ratio and accuracy support reliable metering and protection in your system. Standard ratings and dimensions make integration straightforward.
  • Coils prepared and placed in casting moulds
  • Epoxy cast under vacuum and cured in ovens
  • Ratio, accuracy and insulation tested
Subian CT coil winding production line
Enquiry
Subian CT assembly process
Confirm Quotation
Technician carrying out CT winding work
TestingRatio and accuracy verified.

Void-Free Casting and Accuracy Control

Vacuum casting avoids internal voids, and each finished unit is tested for ratio, accuracy, insulation and partial discharge where applicable. Ratio, polarity and accuracy checks are standard on every unit. By ratio, accuracy class, insulation and quantity. We quote against your specification. Metering and protection classes are available per application requirements.
Subian CT core detail
Send ratio and accuracy requirements.Pricing and drawings for approval.
Visitors at the Subian power equipment booth
Subian booth at an international electrical exhibition
Subian team meeting a customer at an electrical exhibition
Customer visiting the Subian transformer booth
Subian international exhibition team
Subian sales representative discussing a project with a visitor
Visitors at the Subian power equipment booth
Subian booth at an international electrical exhibition
Customer Meetings

Instrument Transformer Sourcing Discussions

Our export team discusses ratios, accuracy classes, system voltage and delivery with distributors and panel builders at exhibitions. Instrument transformers for substation schemes. Current sensing for relays and protection. Component supply for panel builders.
Contact Our Export Team
Product Documentation

Instrument Transformer Certificates and Test Records

Type-test reports, routine test records and certificates for epoxy-cast instrument transformers can be confirmed according to model and market. For the Cast Resin Current Transformer, certificates, type-test reports and routine test records can be confirmed before ordering. Yes, secondary ratings are configured per requirement. Yes, we supply CTs to switchgear and panel manufacturers with OEM options.
Example instrument transformer conformity certificate
Conformity documents
Example instrument transformer type test report
Type-test reports
Packed Subian power equipment prepared for delivery
Packing and shipmentCast units are packed with terminals protected and cast bodies separated.
Product Inquiry

Request Product Information and Pricing

Please provide the product type, rated voltage, capacity, quantity, applicable standard, delivery country and required delivery date. We will reply with a quotation or a list of points requiring confirmation.
  • Product selection and technical clarification
  • OEM, ODM and private-label requirements
  • Quantity, packing and delivery planning

Project and Product Requirements

Fields marked with * are required.
Subian Product Inquiry